5.  Connect electrical wiring.

Run 120 VAC house wiring to installation location. Use 
proper UL approved connector to secure house wiring to 
wiring plate. Connect wires as shown in wiring diagrams.

CONNECT WIRING

INSTALL HOUSING & DUCT

1.  Bend 

housing 
tabs.

Use a pliers to 
bend housing 

TABS

 out to 90

0

.

2.  Mount 

housing to 
joist.

Hold housing 
in place so that 
the housing 
tabs contact the 
bottom of the 
joist. The hous-
ing mounts with 
four (4) screws 
or nails. Screw or 
nail housing to joist through lowest holes in each mount-
ing flange,  then through highest holes. NOTE: Mounting 
to 

I-JOIST

 (shown) requires use of 

SPACERS

 (included) 

between the highest hole of each mounting flange and the 
I-joist.

SPACER

(use for mounting to I-Joist)

I-JOIST

TABS

3.  Attach 

damper/duct 

connector.

Snap damper / 

duct connector 

onto housing. 

Make sure con-

nector is flush with 

top of housing and 

damper flap falls 

closed. If using 

4-inch ductwork, 

install 6” to 4” duct 

reducer (included) over duct connector.

4.  Install 

6-inch or 

4-inch round 

ductwork.

Connect 6-inch 

or 4-inch round 

ductwork to 

damper / duct 

connector. Run 

ductwork to a roof 

cap or wall cap. 

Tape all ductwork 

connections to make them secure and air tight.

Содержание QT140E

Страница 1: ...such products will be free from defects in materials or workmanship for a period of three years from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LI...

Страница 2: ...ing mounted to I joists Use I joist spacer block provided Housing mounted to joists Housing mounted to truss ROOF CAP with built in damper WALL CAP with built in damper 6 IN or 4 IN ROUND ELBOWS 6 IN...

Страница 3: ...t through lowest holes in each mount ing flange then through highest holes NOTE Mounting to I JOIST shown requires use of SPACERS included between the highest hole of each mounting flange and the I jo...

Страница 4: ...e to housing Squeeze grille springs and insert them into tabs on each side of housing 8 Push grille against ceiling 6 Finish ceiling Install ceiling material Cut out around housing Order service parts...

Страница 5: ...lles en la secci n Conexi n el ctrica MODELO QT140E VENTILADOR GARANT A LIMITADA DE TRES A OS DE BROAN NUTONE Broan NuTone garantiza al consumidor comprador original que sus productos estar n libres d...

Страница 6: ...s I suministrado Montaje de cubierta en viguetas Montaje de cubierta en armadura TAPA DE TECHO con amortiguador integral TAPA DE PARED con amortiguador integral CODO REDONDO DE 6 o 4 PULG CONDUCTO RED...

Страница 7: ...reductor de conducto de 6 a 4 pulgadas incluido sobre el conector para conducto 4 Instale el conducto redondo de 6 o 4 pulgadas Conecte el conducto redondo de 6 o 4 pulgadas al conector del regulador...

Страница 8: ...ncuentran a cada lado de la cubierta 8 Empuje la rejilla contra el cielo raso 6 Termine el cielo raso Instale el material del cielo raso Recorte alrededor de la cubierta Al hacer el pedido de una piez...

Отзывы: