INST
ALLA
TION,
USE & CARE INSTR
UCTIONS
INST
ALLA
TION
16
WIRING
WARNING
Risk of electric shock . Electrical wiring must be
done by qualified personnel in accordance with all
applicable codes and standards . Before connecting
wires, switch power off at service panel and lock
service disconnecting means to prevent power from
being switched on accidentally .
NOTES: 1 . Use appropriate wire nuts (not included) for wire
connections .
2 . Refer to FIG . 31 for wire connections .
1 . Connect GREEN or bare wire from house power cable to
one of the unit GREEN ground screw (
) .
2 . Connect
house power cable
to unit wiring: BLACK to
BLACK (
) and WHITE to WHITE (
) .
3 . Connect
No . 2 14/2 cable
to unit wiring: BLACK to
BROWN (
) and WHITE to BLUE (
) .
4 . Using a short ground wire (not provided), connect GREEN
or bare wires from no . 1 and no . 2 cables to the other unit
GREEN ground screw (
) .
5 . Connect
No . 1 14/3 cable
to unit wiring: RED to RED (
),
BLACK to ORANGE (
) and WHITE to PURPLE (
) .
6 . Reinstall the electrical cover in the unit; ensuring the bottom
tabs are inserted in their embossed location . Secure in
place using its retaining screw (FIG . 32) .
NOTE: Not all wires shown .
CAUTION
Take care not to pinch wires while reinstalling wiring
cover .
INSTALL THE FILTER
Ducted Installation
Reinstall the grease filter .
Non-Ducted Installation
Attach the non-ducted filter (included with the HARKPM21
non-duct kit) to the back of the grease filter using
clips (provided with non-ducted filter) . To order a new
non-ducted filter, use service part number S99010464 .
!
HE0449A
NO. 2
14/2 CABLE
NO. 1
14/3 CABLE
1
2
3
4
5
7
8
HOUSE
POWER
CABLE
9
6
FIG. 31
HD1379
FIG. 32
TABS