Operation

To Operate Fan
Use an ON/OFF switch or speed control to operate this 
ventilator.

WARNING

 

Before servicing or cleaning unit,

switch power off at service panel and lock the service 

disconnecting means to prevent power from being 

switched on accidentally. When the service disconnecting 

means cannot be locked, securely fasten a prominent 
warning device, such as a tag, to the service panel. 

Cleaning and Maintenance

To Clean
For quiet and efficient operation, long life and attractive 
appearance, remove Grille and vacuum interior of unit with 
a dusting brush attachment.  
The Motor is permanently lubricated and never needs 
oiling. If the motor bearings are making excessive or 
unusual noises, replace the Motor.

Troubleshooting

Symptom: The fan does not run. 
• Check for an open fuse or circuit breaker in the building’s

service panel. 

• Check that the plug-in connection for the Motor is seated

firmly in place.

• Check that the Blower Wheel spins freely.
Symptom: The fan runs erratically. 
• Check that the Blower Wheel is firmly attached to the

Motor shaft and both spin freely. 

Symptom: The fan seems noisy. 
• Check that the back draft damper in the fan’s Duct

Connector pivots freely. Screws used to attach the 
ducting to the Duct Connector may be preventing the 
damper from opening. 

• Check that the back draft damper in the wall or roof cap

pivots freely. These dampers are sometimes mistakenly
painted shut or obstructed by bird and insect debris.

Содержание LoProfile LPN80

Страница 1: ...SAVE THESE INSTRUCTIONS Installer leave this guide with homeowner Easy installation 2 2 3 6 7 7 7 8 Table of Contents Warnings and Cautions Typical Installation Installation Operation Cleaning and Mai...

Страница 2: ...o the outdoors 7 Acceptable for use over a tub or shower in the ceiling only when connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit 8 This unit must be grounded Typical Ins...

Страница 3: ...sulation stripper Wire cutter Materials needed 4 round metal ducting recommended for best performance Use of other ducting is acceptable but may impact performance Roof cap or wall cap built in damper...

Страница 4: ...Wall or Ceiling UP Wall OR Wire 3 places Screw through housing on opposite side Tighten Screw into housing to secure mounting 1 2 3 2 1 4 3 Install Ducting 1 2 Insert tab into slot in housing 1 2 OR...

Страница 5: ...ing to the Knockout Plate Connect wires as shown in wiring diagram Attach cable clamp to Knockout Plate Knockout Plate may be oriented as desired Connect wires 120 VAC LINE IN GRD WHT BLK GRD WHT BLK...

Страница 6: ...REMOVE MASK BEFORE IN STALLIN G GRIL LE Utiliser ce couvercle pour emp cher la poussi re de construction le pl tre ou la peinture d endommager l int rieur du pro duit ENLEVER LE COUVERCLE AVANT D INS...

Страница 7: ...ubricated and never needs oiling If the motor bearings are making excessive or unusual noises replace the Motor Troubleshooting Symptom The fan does not run Check for an open fuse or circuit breaker i...

Страница 8: ...7 Duct Connector Assembly 2 79140014 Grille Spring 2 included 3 77001282 Grille Assembly includes 2 grille springs 4 77001297 Capacitor 5 77001298 Wire Panel Assembly 6 79110158 4 to 3 Reducer 7 77001...

Отзывы: