Broan InVent AE110S Скачать руководство пользователя страница 4

INST

ALLA

TION 

AND USE & CARE INSTR

UCTIONS

 

INST

ALLA

TION

4

OPTION -

 To mount housing anywhere between ceiling 

framing: Use optional Hanger Bar Kit (sold separately from local 

distributors or website). Follow mounting instructions included 

with kit.

1.  Remove blower and all 

packing material from fan 

housing.

2.  Remove wiring panel from 

fan housing.

ROOF CAP * (with built-in damper)

WALL CAP *

(with built-in

damper)

4-IN. ROUND

ELBOWS *

FAN

HOUSING

Seal gaps

around

housing.

Seal duct joints

with tape.

INSULATION

(Place around and

over fan housing.)

POWER

CABLE *

* Purchase separately.

OR

Keep duct

runs short.

4-IN. ROUND

DUCT *

ALL INSTALLATIONS

Start here.

IMPORTANT -

 The ducting from this fan to the outside 

of the building has a strong effect on the air flow, noise and 

energy use of the fan. Use the shortest, straightest duct routing 

possible for best performance, and avoid installing the fan with 

smaller ducts than recommended. Insulation around the ducts 

can reduce energy loss and inhibit mold growth. Fans installed 

with existing ducts may not achieve their rated airflow.

Cooking

Equipment

Floor

COOKING AREA

Do not install above or

inside this area.

45

o

45

o

NOT FOR USE IN

A COOKING AREA.

 WARNING

•  Disconnect the electrical power supply and lock 

out the service panel.

Содержание InVent AE110S

Страница 1: ...Humidity Sensing Fan Ventilador con sensor de humedad AE80S AE110S Model numbers N meros de modelo INSTALLATION AND USE CARE INSTRUCTIONS INSTRUCCIONES PARA INSTALACI N Y USO Y CUIDADO English See pag...

Страница 2: ...PA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring...

Страница 3: ...back ON and fan will turn ON 50 60 80 70 10 5 60 15 40 20 30 50 HUMIDITY MINUTES HUMIDITY ADJUSTMENT HUMIDITY has been factory set at 80 for most shower applications If fan is not responding to changi...

Страница 4: ...ing POWER CABLE Purchase separately OR Keep duct runs short 4 IN ROUND DUCT ALL INSTALLATIONS Start here IMPORTANT The ducting from this fan to the outside of the building has a strong effect on the a...

Страница 5: ...ector to fan housing Push connector through opening from inside of housing Engage tabs and secure with screw from parts bag 4 Mount housing to ceiling structure TABS Make sure bottom of housing will b...

Страница 6: ...re that the wiring inside of the housing does not interfere with re installation of the blower 8 Install housing mask Place mask into housing opening to prevent drywall spray and construction dust fro...

Страница 7: ...connector Push connector ducting back through opening Engage tabs and secure with screw from parts bag 1 2 3 Install blower Finish ceiling then install grille See Steps 7 8 9 on Page 6 Step 8 is only...

Страница 8: ...019514 Housing 2 97019561 97020122 Duct Connector 4 in AE80S Duct Connector 4 in AE110S 3 97020536 Wire Panel Assembly 4 97020538 Humidity Control Panel Assembly 5 97019785 97019786 Blower Assembly AE...

Страница 9: ...FPA la Sociedad Americana de Ingenieros de Calefacci n Refrigeraci n y Aire Acondicionado American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE y las autoridades normativas...

Страница 10: ...que se energice el ventilador de esta manera se mantendr prendido durante el periodo establecido en el temporizador Para energizar manualmente el ventilador 1 Si el interruptor de alimentaci n ya est...

Страница 11: ...del ventilador CABLE EL CTRICO Se compra por separado O Mantenga cortos los tramos de conductos CONDUCTO REDONDO DE 4 PULG 10 CM TODAS LAS INSTALACIONES Comience aqu IMPORTANTE Los conductos desde es...

Страница 12: ...a trav s de la abertura desde el interior de la cubierta Enganche las leng etas y f jelas con los tornillos de la bolsa de piezas 4 Monte la cubierta en la estructura del cielo raso Aseg rese de que l...

Страница 13: ...montaje planas contra la cubierta CONVERSI N PRECAUCI N Aseg rese de que el cableado dentro de la cubierta no interfiera con la reinstalaci n del soplador 8 Instale la tapa de la cubierta Coloque la...

Страница 14: ...r conducto de vuelta a trav s de la abertura Enganche las leng etas y f jelas con los tornillos de la bolsa de piezas 1 2 3 Instale el soplador Termine el cielo raso y a continuaci n instale la rejill...

Страница 15: ...97019514 Cubierta 2 97019561 97020122 Conector de conducto 4 pulg 10 cm AE80S Conector de conducto 4 pulg 10 cm AE110S 3 97020536 Conjunto del panel de cableado 4 97020538 Conjunto del panel de contr...

Страница 16: ...e presentar una copia de la garant a limitada original por escrito entonces regir n los t rminos de la garant a limitada por escrito m s actualizada de la compa a para su producto en particular Las ga...

Отзывы: