ONTROL

5.5.1  C12 / CM C

ONTROL DESCRIPTION

5.5.2  U

SING

C12 / CM C

ONTROL

• OFF: To stop the unit, slide the button on this position.

• N

ORMAL

: For a day-to-day usage, slide the button on this position. The 

unit then will operate on normal speed.

• B

OOST

: For a high speed operation, slide the button on this position.

Generally used when extreme conditions occur, eg.: parties, 
smokers, etc.

5.  CONTROLS 

(CONT’D)

- 32 -

VC0054

OFF:

U

NIT IS OFF

.

P

OWER INDICATOR

:

LIGHTS UP

WHEN SLIDE SWITCH

IS ON

NORMAL 

OR

BOOST

POSITION

.

F

ILTER MAINTENANCE

INDICATOR

:

FLASHES

EVERY MINUTE TO

INDICATE IT IS ON DUTY

.

FLASHES

EVERY SECOND WHEN

ITS TIME TO REPLACE

PREFILTER

. S

EE

B

IANNUAL

M

AINTENANCE IN

S

ECTION

6.

LIGHTS UP

WHEN ITS TIME TO

REPLACE FILTER AND

PREFILTER

. S

EE

A

NNUAL

M

AINTENANCE IN

S

ECTION

6.

N

ORMAL

:

U

NIT IS OPERATING ON

NORMAL SPEED

.

BOOST:

U

NIT IS OPERATING ON

HIGH SPEED

.

R

ESET FILTER HOLE

:

O

NCE THE MAINTENANCE DONE

RESET THE FILTER

MAINTENANCE INDICATOR BY CAREFULLY INSERTING

A SMALL ROD

(

EG

:

PAPER CLIP

IN THE

R

ESET

F

ILTER

HOLE

DURING

SECOND

. T

HE FILTER MAINTENANCE

INDICATOR WILL TURN OFF

.

Содержание HEPA 1000

Страница 1: ...S MANUAL WITH THE HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGES 28 and 32 to 36 READ AND SAVE THESE INSTRUCTIONS 04313 rev C M O D E L S VB0061 HEPA 2000 HF 2 0 HEPA 3000 HF 3 0 HEPA 4000 HEPA...

Страница 2: ...n NOTE Indicates supplementary information needed to fully complete an instruction We welcome any suggestions you may have concerning this manual and or the unit and we would appreciate hearing your c...

Страница 3: ...l electrical code and local codes and ordinances Do not remove the ground prong Do not use an extension cord 9 Do not install in a cooking area or connect directly to any appliances 10 Do not use to e...

Страница 4: ...A 4000 Unit Installations 12 2 3 1 Stand Alone 12 2 3 2 Central Draw Point 13 2 3 3 Return to Return Installation 14 3 0 DIMENSIONS 15 3 1 HEPA 1000 and HF 1 0 Units 15 3 2 HEPA 2000 HF 2 0 HEPA 3000...

Страница 5: ...du boyau de drainage 27 5 0 CONTR LES 28 5 1 Interrupteur principal 28 5 2 Contr le muraux optionnels 28 5 3 Dimensions 28 5 4 Installation des contr les muraux optionnels 29 5 5 Fonctionnement du co...

Страница 6: ...led Use the following illustrations as guidelines to help you decide on how your unit will be installed All the units should be hung to the joist and installed either vertically or horizontally NOTE F...

Страница 7: ...with radiant hot water or electric baseboard heating Stale air is drawn to the unit by the register located at the highest level of the house Filtered air is supplied by the register located at the lo...

Страница 8: ...in operation but we recommend it See figure below NOTE Home with multiple forced air systems should have 1 unit on each system 2 1 HEPA 1000 AND HF 1 0 UNIT INSTALLATIONS CONT D 8 2 TYPICAL INSTALLAT...

Страница 9: ...ced air system blower must always be ON or the unit efficiency will be affected See figure below NOTE Home with multiple forced air systems should have 1 unit on each system CAUTION Do not connect the...

Страница 10: ...of additional dehumidification may be desirable Quickly remove all excess moisture and keep areas clean HELENA OLYMPIA SALEM BOISE BISMARCK SALT LAKE CITY ST PAUL DES MOINES MADISON HARRISBURG SACRAME...

Страница 11: ...ON or the unit efficiency will be affected See figure below NOTE Home with multiple forced air systems should have 1 unit on each system Do not connect the HEPA 4000 on any forced air system supply du...

Страница 12: ...ating VH0039 A portion of stale air coming from the register located at the highest level of the house is exhausted to the outside and the rest is drawn to the unit Outside fresh air is blended with i...

Страница 13: ...ced air unit For this type of installation it is not essential that the forced air system blower runs when the unit is in operation but we recommend it See figure below NOTE Home with multiple forced...

Страница 14: ...t have motorized dampers If these units are OFF then the forced air unit will draw outdoor air inside NOTE Home with multiple forced air systems should have 1 unit on each system VH0043 14 2 3 3 RETU...

Страница 15: ...HF 2 0 HEPA 3000 HF 3 0 AND HEPA 4000 UNITS FRONT VIEW TOP VIEW 15 3 1 HEPA 1000 AND HF 1 0 UNITS FRONT VIEW TOP VIEW 17 8 452 mm 29 737 mm 22 9 581 mm VK0047 29 4 748 mm VK0048 17 8 452 mm 22 9 581 m...

Страница 16: ...mm VD0117 VD0116 22 559 mm NOTE A minimum of 8 203 mm clearance from any obstruction on top of the unit is required for the ductwork radius turn 8 203 mm VD0118 8 3 4 222 mm 9 3 4 248 mm The joist op...

Страница 17: ...or plenum connection installation only to cut ductwork Aluminum duct tape for plenum connection installation only Jig saw except for the HEPA 1000 unit Caulking gun and caulking except for HEPA 1000 a...

Страница 18: ...t According to your needs you can install the unit either in vertical or horizontal position VD0074 VERTICAL POSITION ALL MODELS HORIZONTAL POSITION LEFT SIDE ALL MODELS HORIZONTAL POSITION RIGHT SIDE...

Страница 19: ...install the front plate and close the door Hang the unit to the floor joist using 4 8 x 1 1 2 screws 4 chains and 4 spings See following illustration 4 4 PLANNING OF THE DUCTWORK Keep it simple Plan f...

Страница 20: ...culation Keep in mind that the filtered air register must be located as far as possible from the stale air register If desired you can install another register sold separately NOTE If an additional re...

Страница 21: ...op the unit for more than 12 hours we recommend to cover the duct with R12 insulation 4 5 2 CENTRAL DRAW POINT AS ILLUSTRATED IN SECTIONS 2 1 2 AND 2 3 2 Stale air ductwork Same as for Stand Alone Sys...

Страница 22: ...pe 4 5 3 RETURN TO RETURN AS ILLUSTRATED IN SECTIONS 2 1 3 AND 2 3 3 Fresh Filtered air ductwork Return side connection Same as for Central Draw Point described in point 4 5 2 Stale air ductwork Retur...

Страница 23: ...ON TO TANDEM TRANSITION 1 For each duct pull back the insulation to expose the interior flexible duct 2 Connect the interior flexible duct to the smaller part of the Tandem transition 5 oval using a 2...

Страница 24: ...ull the insulation over the joint and tuck it between the inner and outer rings of the port Pull the vapor barrier over the insulation and over the outer ring of the port 4 Apply duct tape gently to t...

Страница 25: ...inches 457 mm from the ground See illustration beside 4 7 3 CONNECTING TANDEM TRANSITION TO THE DUAL EXTERIOR HOOD 1 Using a jig saw cut a 6 diameter hole in the exterior wall and insert the Tandem t...

Страница 26: ...late Secure with 2 Xmas tree pins and seal properly with duct tape 3 Lean the exterior backplate to the exteriorwall Using4 8x11 2 screws fix it to the wall Seal the outline with caulking 4 Snap the a...

Страница 27: ...2 sections of plastic tubing one 7 178 mm long and one 27 686 mm long and attach them to each drain fitting as shown VO0028 4 Join these 2 sections to the T junction and main tube as shown VO0029 1 3...

Страница 28: ...units only and C34 CMR control intented HEPA 3000 HF 3 0 and HEPA 4000 units only C12 CONTROL C34 CONTROL CM CONTROL CMR CONTROL 5 3 DIMENSIONS Dimensions are the same for both C12 CM and C34 CMR mod...

Страница 29: ...d wire to hook them to their corresponding screw Connect YELLOW wire to Y screw RED wire to R screw GREEN to G screw and BLACK to B screw See illustration below CAUTION Never install more than one opt...

Страница 30: ...ntrol backplate 6 Route the cable to the unit 7 Remove the front 8 oval port A and the front panel B of the unit by unscrewing their retaining screws CAUTION Keep control low voltage wiring at least 1...

Страница 31: ...the cable through the knock out hole and connect each wire in their corresponding terminal YELLOW in Y RED in R GREEN in G and BLACK in B NOTE Push forward slightly on the little tabs 1 to ease inser...

Страница 32: ...ER INDICATOR LIGHTS UP WHEN SLIDE SWITCH IS ON NORMAL OR BOOST POSITION FILTER MAINTENANCE INDICATOR FLASHES EVERY MINUTE TO INDICATE IT IS ON DUTY FLASHES EVERY SECOND WHEN ITS TIME TO REPLACE PREFIL...

Страница 33: ...the house or the fresh air from a cooling system 5 CONTROLS CONT D VC0048 NORMAL INDICATOR LIGHTS UP WHEN SLIDE SWITCH IS ON NORMAL POSITION UNIT IS OPERATING ON NORMAL SPEED FRESH AIR INDICATOR LIGHT...

Страница 34: ...em wipe with a dry one 3 Slide out the air diffuser HEPA 2000 and HF 2 0 units only the recovery core HEPA 3000 and HF 3 0 units only the energy recovery core HEPA 4000 units only and the filter cartr...

Страница 35: ...8 there is no prefilter 5 Clean the inside walls of the unit with a clean damp cloth them wipe with a dry one For HEPA 2000 and HF 2 0 only Clean the air diffuser with a clean damp cloth them wipe wi...

Страница 36: ...dge including prefilter Install a new HEPA filter cartridge or a new pleated filter cartridge with a new prefilter on it NOTE If you are using a washable foam filter just do the same operations as the...

Страница 37: ...er can garantee No Description Part HEPA 1000 HEPA 2000 Number HF 1 0 HF 2 0 1 Prefilter Kit 2 05123 1 1 2 HEPA Pleated Filter Kit 04803 1 1 3 MERV 12 Filter Kit 04804 1 1 4 Foam Filter MERV 8 Kit 048...

Страница 38: ...rol C12 CM or C34 CMR is connected disconnect control wire from the unit then make sure the unit main switch is properly set in Normal or Boost position If a wall control C12 CM or 2 Unit does not run...

Отзывы: