77
3.1.3 I
N
THE
A
TTIC
CAUTION
Do not install in an attic where the temperature may exceed 160 °F.
1. Using 4 screws no. 8-18 x 0.375 in., install the brackets on the unit as illustrated on previous page in
Figure A. DO NOT USE OTHER SCREWS.
2. Using 4 screws no. 10-12 x 0.625 in., secure the unit to the joists or cross framing.
3.1.4 F
LUSH
-
TO
-C
EILING
💡
If the finishing will be done using the optional decorative finishing trim (part no. FIN-R1015), the
springs included in the optional kit should be installed before installing the brackets.
1. Using 4 screws no. 8-18 x 0.375 in., install the brackets on the unit following the diagram below to
adapt to the thickness of the ceiling. DO NOT USE OTHER SCREWS.
2. Using 4 screws no. 10-12 x 0.625 in., install the unit between the joists. This unit is designed to fit
between 12 in. cc joists. If the joists are closer, do not force the unit in, choose an other installation method.
💡
Prior to painting, clean the metal housing using solvent and the optional decorative trim using water.
VD0469
X
VD0470
X = 5/8"
X = 1 1/4"
X = 1/2"
X = 1 3/8"
SCREW
POSITION
ACCORDING
TO
CEILING
THICKNESS
VD0471