- 4 -
1. INSTALL DUCTWORK
Plan where and how the ductwork will be installed.
Install proper-sized ductwork, elbows and roof or wall cap. Use 2” duct tape to seal duct joints.
The minimum hood distance above cooktop must not be less than 24”. A maximum of 30” above cooktop is
highly recommended for best capture of cooking impurities.
Distances over 30” are at the installer and users discretion.
Hood
7" round duct
Roof cap
Wall
cap
Tran
s
ition model 462
3
¼" x 10" to 7" round
HH0110A
24" minimum above
cookin
g s
urface
Hood
3
¼" x 10" duct
Roof cap
Wall
cap
HH0109A
24" minimum above
cookin
g
s
urface
3
¼" x 14" to
3
¼" x 10" adaptor
model T461 (included)
2. PREPARE THE INSTALLATION
Make sure that the following items are included:
- Hood
- Accessories:
• Filters (2 for 30’’ and 36’’ width hoods)
• Plastic diverter (assembled in hood)
• T461 3¼” x 14” to 3¼” x 10” adapter/damper (inside one filler)
• Bag of parts (inside one filler) including:
(1) wire clamp, (5) no. 8 x 1/2” screws, (2) wire connectors and (3) no. 6 x 1/2” standard screws
Parts sold separately:
-
Shielded halogen lights (MR16, GU10, 120 V, 50 W)
-
Transition 3¼” x 10” to 7” round model no. 412 (optional), ducts, elbows, dampers, wall or roof caps.
NOTES: 1. During installation, protect countertop and/or cooktop.
2. If the bottom of the cabinet is recessed, attach four 1’’ wide wood strips (not included), as shown below,
in order to properly attach the hood to the cabinet. The wood strips must be as thick as recess.
HO002
8
A
CABINET BOTTOM
’’
¾
1
’’
¾
1
10¼
’’
5¼
’’
1
”
1
”
1
”
1
”