background image

9. OPERATION

C. OFF 

BLOWER

 / F

ILTER

 

MAINTENANCE

 

SWITCH

:

Press this switch to turn off the blower. Pressing this switch also cancels the delay function (if activated).

NOTE: After 25 hours of operation, all blower LEDs will flash during 30 seconds to indicate the filters need to be

cleaned in order to maintain efficient hood operation. The LEDS will continue to flash until the function is reset
by pressing on this switch for 3 seconds.

D. OFF 

LIGHTING

:

Press this switch to turn off lighting.

E. H

ALOGEN

 

LIGHT

 

SWITCH

:

Press this switch to turn on the halogen lamps. The lighting intensity changes by increments of 1 (e.g.: Press once for low
intensity, once again to get more, up to three times.) From the higher intensity, press once to go back to the lower intensity.

NOTE: The last lighting intensity used is kept in memory. The next time the halogen lamps will be turned on, they will

light with the last intensity used.

RESET

 

CONTROL

 

PROCEDURE

:

If ever the control locks up, turn off power at the main electrical panel for 5 seconds. Then, turn on power at the main
electrical panel. The control will be reset.

A) Blower Delay switch

D) OFF lighting

B) ON blower / Speed control switch

E) Halogen light switch

C) OFF blower / Filter maintenance switch

HC0016

Always turn your blower on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few
minutes to clear the air after you turn off the range.

HEAT SENTRY™

This hood is equipped with a Heat Sentry thermostat. This thermostat is a device that will turn on or speed up the blower
if it senses excessive heat above the cooking surface.
1) If blower is OFF—it turns blower ON to speed 3.
2) If blower is ON at a lower speed setting—it turns the blower up to speed 3. If blower is at Boost, HEAT SENTRY™

turns blower down to speed 3.

When HEAT SENTRY™ is activated, the first and the last speed blower LEDs are flashing alternately.
When the temperature level drops to normal, the blower will return to its original setting.

WARNING

The HEAT SENTRY™ can start the blower even if the hood is turned OFF. In this case, it is impossible to
turn the blower OFF with blower switch. To prevent the blower from starting, turn off power at the
main electrical panel.

!

- 10 -

A

B

C

D

E

A. B

LOWER

 

DELAY

 

SWITCH

:

When a speed is selected, press the delay switch to activate the delay function. The corresponding speed indicator LED
will start flashing to indicate this function is activated. The fan will continue to operate for 5 minutes and will stop 
automatically. To cancel the delay function, press the blower delay switch once again; the blower will then work in 
normal mode.

NOTE: The blower speed can be increased—or decreased—during delay mode without starting another 5-minute cycle.

B. ON 

BLOWER

 / S

PEED

 

CONTROL

 

SWITCH

:

Press this switch to turn on the blower at the last selected speed. To change the blower speed, press the switch again
until the desired speed is obtained.

NOTES: 1. Each time you press the speed control switch, the speed changes by increments of 1 (e.g.: speed 1 

to speed 2, to speed 3, and then speed 4.) From the fourth speed, the speed goes down to level 1.

2. The last speed used is kept in memory so that when the unit is turned on, it will return to the last setting

except the fourth, the next time the blower will be turned on, it will return to speed 3.

Содержание ELITE E661

Страница 1: ...AND CARE INFORMATION ON PAGES 7 AND 8 Broan NuTone LLC Hartford Wisconsin www broan com 800 558 1711 Broan NuTone Canada Mississauga Ontario www broan ca 877 896 1119 REGISTER YOUR PRODUCT ON LINE AT...

Страница 2: ...Grease should not be allowed to accumulate on fan or filter d Use proper pan size Always use cookware appropriate for the size of the surface element TO REDUCETHE RISK OF INJURYTO PERSONS IN THE EVENT...

Страница 3: ...duration of any implied warranty is limited to the one year period as specified for the express warranty Some states or provinces do not allow limitation on how long an implied warranty lasts so the a...

Страница 4: ...included 2 PREPARE THE INSTALLATION Make sure that the following items are included Hood Accessories Filters 2 for 30 and 36 width hoods Plastic diverter assembled in hood T461 3 x 14 to 3 x 10 adapt...

Страница 5: ...es below is 10 centered 3 1 Pull latch tabs and remove filters from the hood C L HD0121A 3 7 7 2 B 1 dia A 7 8 3 PREPARE THE HOOD 3 2 Remove the 5 screws retaining the bottom panel to the hood and set...

Страница 6: ...utoff plate from the back of the hood by removing the 3 screws Set aside scews 6 3 PREPARE THE HOOD CONT D FOR VERTICAL DISCHARGE ONLY The hood is set up at the factory for vertical discharge Go to st...

Страница 7: ...apter damper This flange must be at 90 from the remaining flanges See picture beside FOR HORIZONTAL DISCHARGE ONLY 4 2 Using three 3 no 6 x 1 2 screws provided secure the adapter to the back of the ho...

Страница 8: ...y 5 1 Run power cable to installation location Position the hood in its intended location Using a pen mark the position of the screws smaller part of the keyholes see pictures below for the 5 keyholes...

Страница 9: ...he halogen lamps must be cooled down before removing them 8 1 Install the lamps by placing the bulb leads into their grooves in the socket and gently push upward and turn clockwise until secured HE004...

Страница 10: ...senses excessive heat above the cooking surface 1 If blower is OFF it turns blower ON to speed 3 2 If blower is ON at a lower speed setting it turns the blower up to speed 3 If blower is at Boost HEAT...

Страница 11: ...s steel surface Avoid when choosing a detergent Any cleaners that contain bleach will attack stainless steel Any products containing chloride fluoride iodide bromide will deteriorate surfaces rapidly...

Страница 12: ...TERS 9 92 x 17 981 2 V06264 FILTERS 12 922 x 17 981 2 8 V02160 CAPACITOR 1 1 9 V06750 BROAN ELITE LOGO 1 1 10 V06733 1 CONTROL PROCESSOR UNIT 1 1 11 V06252 DIVERTER 1 1 12 V05921 HALOGEN LAMP 50 W 120...