background image

Página 15

SERIE CJD1

PIEZAS DE SERVICIO

Las piezas de recambio 

se pueden ahora pedir en 

nuestro Web site. 

Visítenos por favor en

www.Broan.com

3

3

6

5

1

8

2

9

8

13

19

20

23

24

25

8

12

10

8

7

4

21

17

18

16

15

22

14

11

Clave No.   Parte No. 

Descripción

R680508 

7” PLACA DE CONDUCTO REDONDO

  (incluye piezas)

R740013 

3-1/4” X 10” AMORTIGUADOR DE MONTAJE

  (incluye piezas)

R602017 

TORNILLO, #8-18 X 1/4” Hex (2 en paquete)

99150484 

TORNILLO, #8-18 X 3/4”

98011023 

CONTROL DE GUARDIA

97019322 

CONTROL DE CIRCUITO, BLANCO

97019323 

CONTROL DE CIRCUITO, NEGRO

97019324 

CONTROL DE CIRCUITO, ACERO

98010989 

SOPORTE DE CONTROL

R602534 

PAQUETE DE TORNILLOS #8-18 X 3/8

  (2 en paquete)

99271478 

TRANSFORMADOR (incluye piezas)

10 

R401646 

DEFLECTOR

11 

401645 

CONDUCTO DE AIRE

12 

R401647 

MONTAJE DE CONDUCTO DE AIRE

  (incluye piezas)

13 

R602533 

TORNILLO DE TIERRA

14 

R680504 

TAPA DE CABLEADO (incluye piezas)

15 

R99420635  SUJETADOR DE HO RQUILLA

16 

R531075 

ASPA DEL VENTILADOR (incluye Clave No. 15 )

17 

R169002 

TORNILLOS DE MONTAJE DE MOTOR (3 Req.)

18 

R99080535  MOTOR(i ncluye kit de montaje del motor)

19 

R111630 

ENCHUFE DE LAMPARA / MONTAJE DE ARNES

20 

R7201731 

PANEL DE LUZ, 30-PULG BLANCO

R7201734 

PANEL DE LUZ, 30-PULG NEGRO

R720174 

PANEL DE LUZ, 30-PULG ACERO

21 

R607660 

TAPON DE ORIFI CIO

22 

99271469 

ARNES

23 

REMACHE POP .125 DIA (3 req)

24 

R169016 

KIT DE FILTRO DE RESORTE

25 

99010384 

FILTRO DE ALUMINIO 30 PULG. (2 in paquete)

** 

99010308 

KIT DE FILTRO PARA CAMPANA SIN DUCTO KIT, 

  30 P ULG.

** 

97010792 

REGULADOR DE TIRO REDONDO DE 7” 

Ordene partes de reemplazo por número de Parte - no por número de Clave.

* Piezas Estándar - pueden ser compradas localmente.   ** No se muestra - cómprese por separado.

Содержание CJD1 SERIES

Страница 1: ...ERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the fl...

Страница 2: ...retailer and attach them to the aluminum mesh filters NOTE For models that are installed in the non ducted mode the most effective operation is achieved at speeds 1 and 2 These speeds provide the mos...

Страница 3: ...filters aside 7 ROUND DUCT PLATE FILTERS 1 Determine whether hood will discharge vertically 3 x 10 or 7 Round or horizontally 3 x 10 only For vertical or horizontal discharge run ductwork between the...

Страница 4: ...thru 13 are for DUCTED INSTALLATION ONLY BAFFLE 7 Remove Air Chute held in place with one 1 screw NOTE Be careful not to disconnect any wires 9 Rotate baffle Re insert baffle into air chute as shown s...

Страница 5: ...direction of airflow away from range hood 12 3 x 10 Ducted Discharge Only Remove Tape from damper flap and attach Damper Duct Connector over knockout opening with screws removed in Step 4 under PREPAR...

Страница 6: ...urely tighten cable clamp onto house wiring GREEN GROUND SCREW INSTALL THE HOOD KEYHOLE 4 MOUNTING SCREW 4 1 Hang hood from 4 Mounting Screws Slide hood towards wall until mounting screws are engaged...

Страница 7: ...includes hardware 15 R99420635 HAIRPIN CLIP 16 R531075 FAN BLADE includes Key No 15 17 R169002 MOTOR MOUNTING SCREWS 3 Req 18 R99080535 MOTOR includes motor mounting kit 19 R111630 LAMP SOCKET HARNES...

Страница 8: ...e Limited Warranty Remedy During the applicable limited warranty period the Company will at its option provide replacement parts for or repair or replace without charge any Product or part thereof to...

Страница 9: ...TE 1 AHOGUE LAS LLAMAS con una tapa ajustada o charola de metal despu s apague la hornilla TENGA CUIDADO A FIN DE EVITAR QUE MADURAS Si las llamas no se apagan de inmediato EVACUEY AVISE A LOS BOMBERO...

Страница 10: ...NDA siempre la campana antes de comenzar a cocinar con el fin de establecer un flujo de aire en la cocina Despu s de apagar la es tufa deje que la campana funcione durante unos cuantos minutos para de...

Страница 11: ...ltros a un lado PLACA DEL CONDUCTO REDONDO DE 17 8 CM 7 FILTROS 1 Determine si la descarga de la campana va a ser vertical conducto de 8 3 cm x 25 4 cm 3 x 10 o conducto redondo de 17 8 cm 7 horizonta...

Страница 12: ...c tor del conducto para aire 9 Gire el deflec tor Vuelva a insertar el deflector en el conducto para aire de manera seg n lo dem ostrado que las aletas entren totalmente en las ranuras del conducto pa...

Страница 13: ...cerca posible del borde superior posterior de la campana CONECTOR DEL REGULADOR DE TIRO CONDUCTO Se muestra la posici n de descarga vertical CINTA AJUSTE LATERAL HASTA DE 2 5 CM 1 PIVOTE BORDE SUPERI...

Страница 14: ...trica CABLEADO DOM STICO 120 VCA TORNILLO VERDE DE CONEXI N A TIERRA 1 Cuelgue la campana de los 4 tornillos de montaje que se encuentran en la bolsa de piezas Deslice la campana hacia la pared hasta...

Страница 15: ...R 11 401645 CONDUCTO DE AIRE 12 R401647 MONTAJE DE CONDUCTO DE AIRE incluye piezas 13 R602533 TORNILLO DE TIERRA 14 R680504 TAPA DE CABLEADO incluye piezas 15 R99420635 SUJETADOR DE HO RQUILLA 16 R531...

Страница 16: ...able la Compa a a su opci n suministrar piezas de repuesto o reparar o reemplazar sin cargo alguno cualquier Producto o pieza del mismo hasta el grado en que la Compa a lo encuentre cubierto bajo esta...

Отзывы: