background image

INST
ALLA
TION MANUAL

SAFETY

3

READ AND SAVE THESE INSTRUCTIONS

!

 Intended for domestic cooking only 

!

INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.

For Broan range hoods, register your range hood online at www.broan.ca

For NuTone range hoods, register your range hood online at www.nutone.ca

!

 WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO 
PERSONS, OBSERVE THE FOLLOWING:

•  Use this unit only in the manner intended by the manufacturer. If you have 

questions, contact the manufacturer at the address or telephone number 
listed in the warranty.

•  Before servicing or cleaning unit, switch power off at service panel and 

lock the service disconnecting means to prevent power from being 
switched on accidentally. When the service disconnecting means cannot 
be locked, securely fasten a prominent warning device, such as a tag, to 
the service panel.

•  Installation work and electrical wiring must be done by a qualified 

person(s) in accordance with all applicable codes and standards, including 
fire-rated construction.

•  Sufficient air is needed for proper combustion and exhausting of 

gases through the flue (chimney) of fuel burning equipment to prevent 
backdrafting. Follow the heating equipment manufacturer’s guidelines and 
safety standards such as those published by the National Fire Protection 
Association (NFPA) and the American Society for Heating, Refrigeration 
and Air Conditioning Engineers (ASHRAE) and the local code authorities.

•  When cutting or drilling into wall or ceiling, do not

damage electrical wiring and other hidden utilities.

•  Ducted fans must always be vented to the outdoors.

•  Do not use this unit with any additional solid-state speed control device.

•  To reduce the risk of fire, use only metal ductwork.

•  This unit must be grounded.

•  As an alternative, this product may be installed with the UL-approved cord 

kit designated for the product, following instructions packed with the cord 
kit.

•  When applicable local regulations comprise more restrictive installation 

and/or certification requirements, the aforementioned requirements prevail 
on those of this document and the installer agrees to conform to these at 
his own expense.

Содержание BCDA series

Страница 1: ...Serial number 99045652 101C RANGE HOOD Series BCDA BCS3 BCSM NCDA NCS3 and NCSEK INSTALLATION USE AND CARE MANUAL...

Страница 2: ...ed Tools and Accessories for Installation 8 Install Ductwork Ducted Installations Only 8 9 Contents 9 10 Prepare the Hood 11 13 Prepare the Hood Location 14 EZ1 Person Installation 14 16 Install the H...

Страница 3: ...standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow th...

Страница 4: ...d you know how to operate it B The fire is small and contained in the area where it started C The fire department has been called D You can fight the fire with your back to an exit Based on Kitchen Fi...

Страница 5: ...ght OFF NCSEK SERIES BCSM SERIES ON OFF BLOWER PUSH BUTTON When blower is OFF push on this button to turn ON the blower at the last selected speed Push on this button again to turn OFF the blower NOTE...

Страница 6: ...n again until the desired speed is reached from LOW to MEDIUM to HIGH speed to OFF Each time a blower speed is activated a beep is heard and LED indicators light up to show the corresponding speed cho...

Страница 7: ...blade should be cleaned frequently Use a clean cloth soaked with warm detergent solution STAINLESS STEEL CLEANING Do Regularly wash with clean cloth or rag soaked with warm water and mild soap or liq...

Страница 8: ...3 X 10 OR 7 ROUND DUCT FOR VERTICAL DISCHARGE HOUSE WIRING TOP OR BACK OF HOOD HOOD NOTE Distances over 24 are at the installer and user discretion 1 Determine whether hood will discharge vertically 3...

Страница 9: ...gle blower hood B double blower hood 4 10 14 8 7 C C C Bend template along graduated scale when installing to framed cabinet Pour une installation sous une armoire fond en retrait utiliser les lignes...

Страница 10: ...tenter de d couper le trou pour le conduit travers le gabarit NOTE Les d coupes incluent le jeu n cessaire l installation elles ne doivent pas tre du format exact des conduits Use esta plantilla para...

Страница 11: ...p no EZ1 brackets in BCS3 and NCS3 Series Remove both screws holding damper assembly to hood Remove parts bag captured behind the damper assembly Remove damper assembly from inside the hood and keep t...

Страница 12: ...Cable Knockout from top vertical exhaust or back horizontal exhaust of hood Install an appropriate strain relief 1 2 diameter not included NON DUCTED INSTALLATION ONLY 7 Remove 3 screws retaining the...

Страница 13: ...plate can be installed up to 1 2 on either side of the hood center 7 ROUND KNOCKOUT PLATE ALSO REMOVE VERTICAL KNOCKOUT PLATE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10 HORIZONTAL KNOCKOUT PLATE FIGURE 1 A...

Страница 14: ...imple B hotte ventilateur double To be translated in Spanish Electrical access hole center A single blower hood B double blower hood 4 10 14 8 7 C C C Bend template along graduated scale when installi...

Страница 15: ...ear end of bracket against the wall Use a pencil to mark 3 holes there are 6 holes but only 3 are necessary Remove the bracket Using a 7 64 drill bit drill 3 holes where marked Assemble the bracket to...

Страница 16: ...aw a line on the outer edge of the bracket as shown Slide the bracket towards the center of cabinet and align side edge to marked line keeping the rear end edge leaning on the wall Use a pencil to mar...

Страница 17: ...its 2 recessed REAR HOLES A and B While holding the hood run the house power cable into the hood through the strain relief previously installed in step 6 on page 13 4 Unhook the rear holes from the b...

Страница 18: ...o 8 18 x 1 2 metal screws with washers For frameless cabinet secure the hood to the cabinet using four 4 no 8 x 5 8 round head wood screws screws and washers included in parts bag Insert two 2 screws...

Страница 19: ...TING SCREWS 4 ELECTRICAL ACCESS HOLE IN CABINET BOTTOM WOOD SHIMS RECESSED BOTTOM CABINETS ONLY CABINET FRONT 3 4 1 1 7 16 9 24 HOOD 12 30 HOOD 47 16 CABINET BOTTOM 9 24 HOOD 12 30 HOOD 3 X 10 VERTICA...

Страница 20: ...4 mounting screws previously installed Slide hood back towards wall until mounting screw heads are engaged in narrow end of keyhole slots in top of hood Tighten screws securely Attach power cable to...

Страница 21: ...andards Before connecting wires switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally CAUTION Ensure both tabs on inner top of hoo...

Страница 22: ...se to install bulb SUCTION CUP TOOL WARNING Do not touch lamps during or soon after operation Burns may occur In order to prevent the risk of personal injury only install shielded halogen lamps Also n...

Страница 23: ...R FAN MOTOR BN BN W G Y R Low BK High W 120 V AC Line Neutral Ground BK BK Motor Switch Light Switch BL W W BK BK COLOR CODE BK BL BN BLACK BLUE BROWN R W RED WHITE BN W G Y O BROWN WHITE GREEN YELLOW...

Страница 24: ...on back of control board J1 Transformer J2 Power Motor 5 4 3 2 1 5 4 3 2 1 6 7 Control Board R BK R R BL BL BK W BK BK W G Y R Low O Medium BK High W 120 V AC Line Neutral Ground G Y W BK O R FAN MOT...

Страница 25: ...Y RED WHITE YELLOW BN W G Y O BROWN WHITE GREEN YELLOW ORANGE 120 V AC Line Neutral Ground 1 2 3 4 5 6 1 2 3 4 5 6 G Y G Y W W W W W BK High BK BK BK O Medium BK O R Low R FAN MOTOR BN W BN Y Low BL...

Страница 26: ...FAN MOTOR BN BN W G Y R Low BK High W 120 V AC Line Neutral Ground BK BK Motor Switch Light Switch Y Low BL High W W BK BK COLOR CODE BK BL BN BLACK BLUE BROWN R W Y RED WHITE YELLOW BN W G Y O BROWN...

Страница 27: ...EWS 1 S97020031 RECIRCULATION COVER PLATE STAINLESS STEEL INCLUDING SCREWS 1 2 S97018567 7 ROUND DUCT PLATE INCLUDING SCREWS 1 1 1 3 S97020534 3 X 10 DAMPER ASSEMBLY INCLUDING SCREWS 1 1 1 4 S97020408...

Страница 28: ...3 CAPTOUCH CONTROL LED BLACK WITH SCREWS 1 S97020360 PARTS BAG INCLUDING 4 METAL SCREWS NO 8 18 X 1 2 4 WASHERS 6 ROUND HEAD NO 8 X 5 8 WOOD SCREWS 6 NO 8 X 1 2 COUNTERSUNK SCREWS 1 1 1 S97020466 NON...

Страница 29: ...0448 WIRE HARNESS 1 1 1 1 1 S97018623 PARTS BAG INCLUDING 5 ROUND HEAD NO 8 X 5 8 WOOD SCREWS 1 SUCTION CUP TOOL 1 1 1 1 1 S97020465 NON DUCTED FILTER TYPE XB SET OF 2 NON DUCTED INSTALLATION ONLY 1 1...

Страница 30: ...WIRE HARNESS 1 1 1 S97018623 PARTS BAG INCLUDING 5 ROUND HEAD NO 8 X 5 8 WOOD SCREWS 1 SUCTION CUP TOOL 1 1 1 S97020466 NON DUCTED FILTER TYPE XC SET OF 2 NON DUCTED INSTALLATION ONLY 1 1 1 S99527587...

Страница 31: ...WS 6 NO 8 X 1 2 COUNTERSUNK SCREWS 1 1 S97020466 NON DUCTED FILTER TYPE XC SET OF 2 NON DUCTED INSTALLATION ONLY 1 1 S99527587 NON DUCTED FILTER CLIP KIT INCLUDES 4 CLIPS 1 1 S97020038 SHIELDED HALOGE...

Страница 32: ...t parts to you at no charge You are responsible for all costs for removal reinstallation and shipping insurance or other freight charges incurred in the shipment of the Product or part to the Company...

Отзывы: