3. CONNECTIONS
(
Cont
’
d
)
3.2 e
lectricAl
c
onnection
to
o
ptionAl
A
uxiliAry
w
All
c
ontrol
3.2.1 e
lecTrical
c
onnecTion
To
20-40-60 o
pTional
a
uxiliarY
w
all
c
onTrol
Gnd
OVR
12V
LED
VC0243
Gnd
OVR
12V
LED
When configurating OVR option on the LCD screen, choose among these 3 configurations: BAL (the unit remains balanced while
providing maximum airflow), PER (the unit is slightly unbalanced since the distribution motor is in MAX speed while allowing maximum
exhaust ventilation) and DIS (the unit is unbalanced since air distribution is constant despite a higher need in exhaust ventilation).
NOTE :
The auxiliary wall control can be used with a 3-wire connection by removing the LED signals. This optional wiring will not allow an
installation with more than 1 auxiliary wall control to properly synchronize their LEDs on an event requested from a peer. Only the
auxiliary wall control having requested the timer event will have the LEDs updated accordingly.
3.2.2 e
lecTrical
c
onnecTion
To
d
rY
c
onTacT
o
pTional
a
uxiliarY
w
all
c
onTrol
(
e
.
G
. c
rank
T
imer
)
Crank Timer
or
Any Dry Contact
12V
OVR
VC0256