Page 4
ALLURE
®
QS1 SERIES
RANGE HOOD
CONNECT WIRING
WARNING: To reduce the risk of electric shock,
make sure power is switched off at the service
panel. Lock or tag service panel to prevent power
from being switched on accidentally.
HOUSE
WIRING
(120 VAC)
CARDBOARD
(U
SE
TO
PROTECT
COOKTOP
)
1 Connect
House Wiring
(120 VAC) to hood. Use a piece of
Cardboard
to protect the cooktop, if necessary.
2
Connect house BLACK to hood BLACK wire, house WHITE to
hood WHITE wire, and house ground under
GREEN Ground
Screw
. Securely tighten cable clamp onto house wiring.
GREEN
GROUND
SCREW
3
Replace wiring cover.
PREPARE THE HOOD
10 Remove appropriate
Duct Knockout
from top or back of
hood.
REAR
RECTANGULAR
DUCT KNOCKOUT
(
REMOVE
FOR
3¼”
X
10”
HORIZONTAL
DISCHARGE
)
TOP RECTANGULAR DUCT KNOCKOUT
(
REMOVE
FOR
3¼”
X
10”
VERTICAL
DISCHARGE
)
11 3¼” x 10” Ducted Discharge Only: Attach
Damper/Duct
Connector
over knockout opening. Make sure damper
Pivot
is nearest to
Top/Back Edge
of hood. Remove
Tape
from
damper
fl
ap.
DAMPER/DUCT
CONNECTOR
(V
ERTICAL
DISCHARGE
POSITION
SHOWN
)
TAPE
NOTE Damper/Duct Connector can be installed up to 1-inch
on either side of hood center to accomodate off-center
ductwork. In extreme off-center installations, one end of
the duct connector may need to be trimmed to clear the
electrical cable clamp.
UP TO 1”
SIDE-TO-SIDE
ADJUSTMENT
PIVOT
TOP/BACK
EDGE