Page 3
MODEL 791LED
B L K
V E N T
S W I T C H
B L U
B L K
W H T
W H T
W H T
L I G H T
( W H I T E )
G R D
V E N T
( B L A C K )
U N I T
S W I T C H B O X
L I G H T
S W I T C H
L I N E
I N
B L K
R E D
W H T
G R D
SCHEMATIC WIRING DIAGRAM
FINISH THE INSTALLATION
INSTALL THE DUCTWORK
NOTE:
The duct connector has a counter-balanced damper
flap. The flap will be “open” approx. 1” when duct connector
is attached to housing. This design permits insulation to be
in direct contact with fan/light housing per UL (Underwriters
Laboratories) standards. The slightest backdraft, however,
will close the damper flap, preventing air from entering unit
or finished space.
CONNECT THE WIRING
1. Connect 4” round
duct to damper/
duct connector
and extend duct
to outside through
a roof or wall cap.
Check damper to
make sure that it
opens freely. Tape
all duct connections to make them secure and air tight.
1. Wire unit as shown. Re-install wiring plate removed in
Step 2 under “PREPARE THE HOUSING”.
2. Run electrical cable as direct as possible to unit. Do not
allow cable to touch sides or top of unit after installation
is complete.
2. Locate grille over fan housing. Squeeze grille springs
together and insert springs into slots in sides of
housing.
3. Connect LED wire connectors together.
4. Push grille up against ceiling.
4. Place housing in
opening so that
its bottom edge is
flush with finished
ceiling. Screw
housing to joist
through holes in
housing as shown.
5. Seal between
ceiling material and
housing to prevent
air leakage.
SEAL BETWEEN CEILING
MATERIAL & HOUSING
MOUNTING SCREWS
1. Re-install blower
assembly removed in
Step 1 under “PREPARE
THE HOUSING”. Plug
blower into black
receptacle and light plug
into white receptacle.
USE AND CARE
Operation
To Operate Fan and Light
Use only an ON/OFF or timer switch to operate the fan.
Use only an ON/OFF switch, timer switch or relay-switch
to operate the LED light.
The LED light cannot be used with a dimmable switch.
Both the fan and LED light can be put on one switch.
WARNING
Before servicing or cleaning unit,
switch power off at service panel and lock the service
disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
LED WIRE
CONNECTORS
GRILLE
SPRINGS
SWITCH BOX
LIGHT
FAN
DUAL CONTROL
(purchase separately)
WHITE
BLACK
RED
GROUND
(bare)
120 VAC LINE IN
BLUE
BLACK
RECEPTACLE
(FAN)
WHITE
RECEPTACLE
(LIGHT)