53-1004106-15 Installation Guide
Brocade
®
X6-4 Director Hardware Installation Guide
2. Determine any differences between the information in the
SANafter.txt
file and the information in the
SANbefor.txt
file created earlier. In particular, look for differences in the following:
•
Device types
•
Number of devices
•
ISL and port states
•
Number of switches in the fabric
3. If an SCC policy exists on the active fabric where you are connecting the new chassis, modify the policy to include the
WWN of the new chassis.
•
Refer to the
Brocade Fabric OS Administration Guide
for information on SCC policy.
•
Use the
wwn
command to determine the WWN of the chassis.
•
Use the
secPolicyAdd
command to modify an existing policy.
4. Resolve any issues or unintentional changes to the device or fabric:
•
If there are any mechanical problems, try reseating the associated component.
•
If the configuration information is not correct for the device, modify as required.
•
If other issues exist, contact your support provider.
53-1004106-15
183