1
When CFE is not able to initialize the system and reach the console prompt, the four-character alphanumeric
LED display may be used to help debug the initialization sequence. When the Cer2 message appears, a cache
error has occurred. This frequently occurs when the BCM1125H is either undercooled or is in a low-voltage
situation. Ensure that the correct voltage and cooling is being provided. For other LED message descriptions,
refer to the
Common Firmware Environment (CFE) Specification document.
2
There is no output coming from the serial boot console, but the four-character LED displays
CFE. Because
CFE uses serial port 0 by default, ensure that a standard 9-pin RS232 null-modem cable connection is being
used. Also ensure that the terminal program is set to a baud rate of 115200, 8-bit, no parity, no flow control.
R
EPLACEMENT
P
ARTS
Table 10: Replacement Parts
Board
ID
Description
Manufacturer
Manufacturer ID Web Information
F1
BCM1125H 2.5V power
5A current limit
Littelfuse
®
154005
F2
BCM1125H 3.3V power
1A current limit
Littelfuse
®
154001
F3
EJTAG connector 0.5A
32V surface mounted
fuse.
Littelfuse
®
434.500
BT1
RTC battery.
Panasonic
BR1225/1HC