Multi-Standard Analogue TV Demodulator
Showman 1000
Operation
2008 dB Broadcast Ltd
35
Provisional Version 0.3
To enter the Configuration (Config.) Options menu from DEFAULT:
Press <ENTER>
▼ ▼ <ENTER>
Pressing
▲ or ▼ will cycle the display through some or all of the following
Configuration Option items:
Input Source
The choice is between RF and IF Input.
From Config. Options - Input Source:
Press <ENTER>
Press
▲ or ▼ to select
IF or RF Input.
Press <ENTER> to accept or <ESCAPE> to reject the selection.
Press <ESCAPE> again to return to DEFAULT.
RF Alarm Level
Apply an RF Input at the required RF Alarm trip threshold level.
From the Config. Options - RF Alarm Level:
Press <ENTER> <ENTER> to Set the RF Alarm Level.
Press <ESCAPE> <ESCAPE> to return to DEFAULT.
Video Output Level
The video output level is factory set to provide a nominal value of 700mV (100IRE for M/N
Standard) when terminated in 75Ω. This may be adjusted via the Configuration Option
-
Video Output Level menu.
WARNING:
Adjusting the Video Output Level affects all Channels and Standards.
From Config. Options - Video Output Level:
Press <ENTER>
Press
▲ or ▼ to adjust the Video Output Level.
Press <ENTER> to accept or <ESCAPE> to reject the selection.
Press <ESCAPE> <ESCAPE> to return to DEFAULT.
Video Mute Set
When Video Mute Set is enabled, a check is made for Showman 1000 synchronisation with
the incoming RF signal. Where none is detected, then the video output is muted. The Video
Mute Set factory default is Mute Disabled.
From Config. Options - Video Mute Set: