NTP Server Sentinel

®

Installation and Operation Manual

OVERVIEW

Product Overview

The NTP Server Sentinel® is a standalone "ready-to-run" GPS referenced NTP

time server offering a complete solution for synchronizing the time across TCP/IP
LANs using NTP.  The NTP Server Sentinel® combines a GPS receiver with an embed-
ded web based controller and is configured and managed via a web browser.  The mon-
itor and control web page displays date, time, locked satellite signal strength with mul-
tiple display features.  The NTP Server Sentinel® can handle multiple requests per sec-
ond, making it the choice for providing accurate time information.  The concept is as
simple as plugging the controller into the network, attaching the GPS receiver, config-
uring the unit and allowing any client to request “highly accurate” time.  

Additional features include; three separate GPS time referenced outputs. The

first is a DPDT relay, which operates at 12:00, 22:00, 42:00, 54:30 each hour and is
user programmable in each of four storage locations for any minute and second each
hour. The second output is an active high driver with a 100 ms pulse each second,
while the third output provides an active high driver in the ESE TC89 or TC90 serial
time code format.  Indicator LED's are provided to display; power, 1PPS activity, seri-
al time code activity and time sync relay operation.  The NTP Server Sentinel® is sup-
plied with a Garmin GPS18 receiver, which tracks up to 12 satellites.  The GPS-18 can
be positioned up to 100 feet away from the controller, using standard CAT5 cable.  The
controller may be desk mounted or up to three units may be mounted on our RA-1, 1-
RU rack shelf.  The controller is supplied with a domestic DC power supply.

Features/Benefits

Ready-to-operate Stratum 1 NTP Time Server. 

Support for NTP and SNTP compatible clients. 

Configured across network via web browser. 

Upgradeable flash memory. 

RJ-45 Ethernet interfaces 10/100 base-T. 

Web based display for Time and Satellite Status. 

Standard CAT5 GPS receiver cable length up to 100 feet.

TC 89 or TC90 serial time code output.

1-pulse-per-second output.

User-programmable time sync relay.

Email logging and error reporting 

Secure proprietary operating system for enhanced security 

One year warranty

Applications:

Standalone "ready-to-run" GPS referenced NTP time server.
TC89 or TC90 serial time code source.
Time sync closures for legacy systems.

Inspection

Please examine your NTP Server Sentinel® carefully for any damage that may have
been sustained during shipping.  If any damage is noted, please notify the shipper
immediately and retain the packaging for inspection by the shipper.  The package
should contain the NTP Server Sentinel®, a Garmin GPS18 LVC GPS receiver, this
manual and/or CD, 7 foot BLUE straight-through CAT 5 cable, 7 foot GRAY
crossover CAT 5 cable, and the 7.5 to 9.0 VDC wall transformer.  Manuals may also
be downloaded from our web site.

Содержание NTP Server Sentinel

Страница 1: ...ools Inc All Sentinel labeled products are a trademark of Broadcast Tools Inc Copyright 1989 2015 by Broadcast Tools Inc All rights reserved No part of this document may be reproduced or distributed w...

Страница 2: ...utput connections STC 6 Time Sync Relay connections TS K1A B 6 Front panel status indicators 6 Web Setup Operation 7 Ethernet Quick Start guide 7 Opening the LOGIN Web Page 10 Login Web Page 11 Monito...

Страница 3: ...engineer to handle the installation and setup of the NTP Server Sentinel Broadcast Tools Inc is unable to support NON Broadcast Tools software hardware or NON Broadcast Tools computer hardware softwar...

Страница 4: ...code activity and time sync relay operation The NTP Server Sentinel is sup plied with a Garmin GPS18 receiver which tracks up to 12 satellites The GPS 18 can be positioned up to 100 feet away from the...

Страница 5: ...A UPS helps minimize the risk to the NTP Server Sentinel and provides power dur ing a power outage DC POWER connector This is the connector used to power the unit Never use any type of power supply o...

Страница 6: ...receiver is equipped with a metric M3 x 4mm threaded magnetic base use this to secure the receiver to a user provided mounting bracket The receiver may also be secured with a small strip of Velcro Do...

Страница 7: ...e that these instructions are specifically for computers with the Windows XP operating system For setup using other operating systems refer to the appropriate OS user s manual Step 1 Open the control...

Страница 8: ...nnections The following menu will pop up Step 3 Right click on the icon labeled Local Area Connection Another menu will appear Select the option at the bottom of the menu labeled Properties The Local...

Страница 9: ...making any changes to the network settings write down the current settings or screen capture the page and print so that they can be restored once the unit is configured Next select the radio button l...

Страница 10: ...he supplied DC power supply to the product s power jack labeled Power Verify that the green POWER LED and left LINK LED above the NET Network RJ 45 are illuminated 3 Open the product s login page by t...

Страница 11: ...our web site for product updates and additional information Login Web Page The Login screen displays the username and password entry points Site ID and time date After you have successfully logged in...

Страница 12: ...ength Elv Calculated elevation of satellite in degrees relative to current GPS fix location Az Calculated azimuth of the satellite in degrees relative to current GPS fix location GPS Status Indicates...

Страница 13: ...e following access About Monitor Control Show log Help and Logout 3 Monitor Only allows the following access About Monitor only Help and Logout Values on this page can only be defined by users with ad...

Страница 14: ...nabled Enables or disables serial time code output TC Format Allows you to set time code output to desired format Either TC89 or TC90 TC Frequency Sets serial time code operating frequency Relay Closu...

Страница 15: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 15 NTP Server Sentinel Installation and Operation Manual OPERATION Email Network Setup Web Page...

Страница 16: ...net In order to resolve the URI a work ing DNS server must be present or its IP address entered into the system SMTP Port Normally Port 25 Default 25 SMTP Return Address Enter your return email addre...

Страница 17: ...in hours that the collected snap shots are emailed This email may contain multiple snapshots if the Snapshot Interval is less than the Update Interval Each snapshot will be identified by the date and...

Страница 18: ...s are enabled Email Network Setup Web Page Other Settings Site ID This is the Site Identifier that will be sent in each email an displayed on the web pages Monitor Refresh Time Sec Monitor Control pag...

Страница 19: ...alert box will pop up indicating the status of the email and an error con dition if the email was not sent correctly If an email was not sent correctly please review your SMTP set tings and correct a...

Страница 20: ...ed and operating properly on your PC for the Alarm Sound to work when enabled Show Alarms Web Page This page displays a log of current and past events alarms With the admin access level the user may c...

Страница 21: ...and Operation Manual OPERATION About Web Page The About Web Page displays the product name firmware version numbers and Broadcast Tools web site link This page also contains version and diagnostic dat...

Страница 22: ...on cable may be added GPS Receiver Connector RJ45 Configuration Web page EMI FCC Compliance See the Declaration of Conformity page Operation is sub ject to the following two conditions 1 This device m...

Страница 23: ...s NO OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO...

Страница 24: ...missions EN55022 1998 IEC CSPIR22 1993 Radiated RF emissions 30MHz 1000MHz Conducted RF Emissions Telecom Lines 150KHz 30MHz FCC Part 15 Subpart B Class B IEC 1000 3 2 A14 2000 IEC 1000 3 3 1994 Elect...

Страница 25: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 NTP Server Sentinel Installation and Operation Manual 25 APPENDIX...

Страница 26: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 26 NTP Server Sentinel Installation and Operation Manual APPENDIX...

Страница 27: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 NTP Server Sentinel Installation and Operation Manual 27 APPENDIX...

Страница 28: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 NTP Server Sentinel Installation and Operation Manual 28 APPENDIX...

Отзывы: