background image

30

I/O Sentinel 4 G2 Installation and Operation Manual

LIMITED WARRANTY

LIMITED WARRANTY

The term “Buyer” as used in this document refers to and includes both (but only) (a) any person or entity who acquires such an item for
the purpose of resale to others (i.e., a dealer or distributor of an item), and (b) the first person or entity who acquires such an item for
such person’s or entity’s own use. 

Broadcast Tools warrants to each Buyer of any item manufactured by Broadcast Tools that the item will be free from defects in materi-
als and workmanship at the time it is shipped by Broadcast Tools if the item is properly installed, used and maintained. 

EXCLUSIVE REMEDIES

If Broadcast Tools is notified, in writing, of a failure of any item manufactured by Broadcast Tools to conform to the foregoing Limited
Warranty within one (1) year following the date of the Buyer’s acquisition of the item, and if the item is returned to Broadcast Tools in
accordance with Broadcast Tools’ instructions for confirmation by inspection of the defect (which at Broadcast Tools’ election may
include, without limitation, a requirement that the Buyer first obtain a Return Authorization number from Broadcast Tools, that the Buyer
furnish proof of purchase in the form of an invoice and/or receipt, and that the Buyer prepay all freight charges associated with any return
of the item to Broadcast Tools using such freight service as Broadcast Tools reasonably may specify), Broadcast Tools will repair or
replace the defective item, or will refund the purchase price paid by the Buyer for the item.  Broadcast Tools shall have the exclusive
right to choose between these alternative remedies.

NO OTHER WARRANTIES OR REMEDIES

TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, BROADCAST TOOLS AND ITS SUPPLIERS DISCLAIM ALL OTHER
WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABIL-
ITY OR FITNESS FOR A PARTICULAR PURPOSE; AND THE FOREGOING ALTERNATIVE REMEDIES SHALL BE EXCLUSIVE OF
ALL OTHER REMEDIES.  THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS.  YOU MAY HAVE OTHER RIGHTS,
WHICH VARY FROM STATE/JURISDICTION TO STATE/JURISDICTION.

NO LIABILITY FOR CONSEQUENTIAL DAMAGES

TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, NEITHER BROADCAST TOOLS NOR ANY OF ITS SUPPLIERS
SHALL HAVE ANY LIABILITY FOR ANY SPECIAL, INCIDENTAL, INDIRECT, CONSEQUENTIAL OR PUNITIVE DAMAGES WHATSO-
EVER (INCLUDING, WITHOUT LIMITATION, ANY DAMAGES FOR LOST PROFITS, BUSINESS INTERRUPTION, LOSS OF DATA OR
INFORMATION, COST OF CAPITAL, CLAIMS OF CUSTOMERS, OR ANY OTHER PECUNIARY LOSS) ARISING OUT OF THE USE
OF OR THE INABILITY TO USE ANY ITEM SUPPLIED BY BROADCAST TOOLS, EVEN IF BROADCAST TOOLS HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES HAVE ANY LIABILITY FOR ANY SPECIAL, INCIDENTAL, CONSEQUENTIAL,
EXEMPLARY OR PUNITIVE DAMAGES.  THIS LIMITATION OF LIABILITY APPLIES WHETHER A CLAIM IS ONE ALLEGING
BREACH OF A CONTRACT OR WARRANTY, NEGLIGENCE OR OTHER TORT, FOR THE VIOLATION OF ANY STATUTORY DUTY,
THE FAILURE OF ANY LIMITED OR EXCLUSIVE REMEDY TO ACHIEVE ITS ESSENTIAL PURPOSE, OR ANY OTHER CLAIM OF
ANY NATURE.  BECAUSE SOME STATES AND JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY
FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, THIS LIMITATION MAY NOT APPLY TO YOU.

Broadcast Tools, Inc.

131 State Street

Sedro-Woolley, WA 98284 • USA

360.854.9559 

voice

866.783.1742 

fax

[email protected] 

e-mail

www.broadcasttools.com 

website

e-mail: 

[email protected]   

voice: 

360.854.9559   

fax: 

866.783.1742 

Содержание I/O Sentinel 4 G2

Страница 1: ...marks of Broadcast Tools Inc Copyright 1989 2022 by Broadcast Tools Inc All rights reserved No part of this document may be reproduced or distributed without permission Visit www broadcasttools com fo...

Страница 2: ...e Prep 6 Relay Outputs 6 Status Inputs 7 Operation 8 Reset to Defaults 8 Ethernet Quick Start Guide 9 Opening the LOGIN Web Page 12 Web Setup Operation 13 Login Web Page 13 Monitor Control Web Page 14...

Страница 3: ...ou are unfamiliar with this type of equipment please contact a properly qualified engineer to handle the installation and setup of the I O Sentinel 4 G2 WHO TO CONTACT FOR HELP If you have any questio...

Страница 4: ...may be paired with a second I O Sentinel 4 G2 to form an IP based 4 Channel Bi directional Status Relay Extension Cord Features Benefits Four optically isolated inputs configurable for dry signals or...

Страница 5: ...and or other high voltage surges may damage your I O Sentinel 4 G2 and connected equipment if it is not properly protected For lightning protection devices check out www polyphaser com and www itwlin...

Страница 6: ...e terminals accommodate wire sizes from 16 28 AWG solid or stranded wire Before installing a wire remove the euro block screw termi nal plug and turn each capture screw fully counterclockwise Strip ea...

Страница 7: ...no external resistor is necessary if the input voltage is between 5 and 24 VDC Higher DC volt ages from 25 to 48 VDC can be used but must be reduced with an additional exter nal resistor of the approp...

Страница 8: ...5 and 24 VDC or 25 48 VDC with an added resistor remove both jumpers and place ONE jumper over pins 2 3 Operation The I O Sentinel 4 G2 can be controlled from over the network from its HTML based web...

Страница 9: ...onfiguration of this product are given here Note that these instructions are specif ically for computers with the Windows 10 operating system but will also work with Windows 7 For setup using other op...

Страница 10: ...or product updates and additional information Step 2 Click on the sidebar labelled Change adapter settings The Network Connections windows will pop up as shown below Step 3 Right click on the icon lab...

Страница 11: ...e making any changes to the network settings write down the current settings or screen capture the page and print so that they can be restored once the unit is configured Next select the radio button...

Страница 12: ...and the products NET network RJ45 s jack 2 Connect the supplied power supply Verify that the green PWR Heartbeat LED is blinking and the left LINK LED above the NET Network RJ 45 is illu minated 3 Ope...

Страница 13: ...ax 866 783 1742 13 I O Sentinel 4 G2 Installation and Operation Manual SETUP Web Setup and Operation Login Web Page The Login screen displays the Username and Password entry points WEBSITE Visit our w...

Страница 14: ...will be displayed Depending on your access level you may or may not be able to control or modify the product s configuration Monitor Control Web Page The Monitor Control page allows the monitoring and...

Страница 15: ...te Determines how each relay will function The relays may be config ured for one of three states 1 ON and OFF operation 2 Pulse with user configured pulse length from 100 ms to 2000 ms in 100 ms steps...

Страница 16: ...onfiguration access and control 2 Monitor Control allows the following access About Monitor Control Show log Help and Logout 3 Monitor Only allows the following access About Monitor only Help and Logo...

Страница 17: ...ETUP I O Setup Inputs Web Page The I O setup page allows you to label and configure the status inputs and relay out puts Use the drop down menu to select Inputs or Outputs and the Input x and Output x...

Страница 18: ...applied to the input it is considered OFF When NO voltage is applied to the input it considered ON NOTE By enabling the ON and or OFF monitoring and NOT enabling an email box the device will log the e...

Страница 19: ...broadcasttools com voice 360 854 9559 fax 866 783 1742 19 I O Sentinel 4 G2 Installation and Operation Manual SETUP I O Setup Relays Web Page WEBSITE Visit our web site for product updates and additio...

Страница 20: ...ables email alarms with an ON relay Email Addresses The ON boxes labeled 1 thru 8 allow the user to enable up to eight different email addresses for on alarms Log Device This enables the email snapsho...

Страница 21: ...oadcasttools com voice 360 854 9559 fax 866 783 1742 21 I O Sentinel 4 G2 Installation and Operation Manual SETUP WEBSITE Visit our web site for product updates and additional information Email Networ...

Страница 22: ...MTP Return Address Enter your return email address here Emails from the I O Sentinel 4 G2 will indicate they are from this address If an email cannot be delivered a message stating why will be sent to...

Страница 23: ...the Snapshot Interval is less than the Update Interval Each snapshot will be identified by the date and time Email Network Setup Web Page Email Alarm Settings Email Alarms Choose Immediate and or Dail...

Страница 24: ...enabled Email Network Setup Web Page TCP Relay Relay Extension Cord TCP Relay Enable Check to pair with a second I O Sentinel 4 G2 to form a relay extension cord Relay Peer IP address Enter the IP add...

Страница 25: ...x bytes 32 characters are required inserting 0 where required i e 0xA would be entered as 0A The checkbox Enable Encryption must also be checked It is important to verify that both devices are config...

Страница 26: ...he Reboot Device button the internal web server restarts Send Test Email Press this button to send a test email to recipient address 1 NOTE After you are done making changes to the Email Network Setup...

Страница 27: ...llation and Operation Manual SETUP Show Alarms Web Page This page displays current alarms Controls Disable Sound Mutes the alarms sound Silence Alarms Makes active alarms as acknowledged Clear Alarms...

Страница 28: ...tion Manual SETUP About Web Page The About web page displays the product name firmware version numbers and Broadcast Tools web site link For firmware updates please contact Broadcast Tools Technical S...

Страница 29: ...4 SPDT relays 30 VDC 1 Amp maximum rating With front panel LED indicators Connectors 4 Removable euro block screw terminals Mating plugs supplied Required power supply 9 to 12 VDC only greater than 5...

Страница 30: ...NO OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO I...

Страница 31: ...2A 4B 2B GND GND 3CM 1CM 3NO 1NO 4NC 2NC 4CM 2CM 4NO 2NO 1 2 3 4 I O Sentinel 4 G2 PWR HB INPUTS OUTPUTS Def 1 2 3 4 e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 I O Sentinel...

Страница 32: ...ut Configuration Jumpers Power 9 12VDC LAN NET Chassis Ground Relay Outputs 1 4 I O Sentinel 4 G2 I O Sentinel Component Layout LEDs Relay Output I O Sentinel Component Layout LEDs Relay Output LEDs I...

Страница 33: ...atic I O Sentinel 4 G2 Modified 3 21 22 131 State Street Sedro Woolley WA 98284 360 854 9559 Fax 866 783 1742 Copyright 1989 2022 by Broadcast Tools Inc All Rights Reserved Visit us online at www broa...

Страница 34: ...evice s Relay Receive Port and send a TCP Relay Command as described in the table below The device will respond with a query command response packet and close the TCP connection The response packet is...

Страница 35: ...for Set Relays 1 1 CMD_LENGTH The number of relay state pairs to be set 2 2 RELAY_NUMBER The zero indexed number of the relay who s state should be set to the state specified in the byte below 3 3 RE...

Страница 36: ...equest All data returned from a valid GET request is in JSON format and varies between the devices depending on what features they support The following are standard files cgi bin getexchanger cgi Bas...

Страница 37: ...e sub ject to change between releases To determine the proper KEY VALUE paring for specific BTI Sentinel devices the use of Firefox FireBug or the built in debugger in Chrome can be used to see how th...

Отзывы: