Broadcast Tools DSC-20 Скачать руководство пользователя страница 3

Broadcast Tools, Inc.

DSC-20, Dual Satellite Receiver Controller Set-up guide

Installation and Operation Manual

Broadcast Tools, Inc.

Page 3

PRODUCT DESCRIPTION

The

 

DSC-20

 allows the remote control of any combination of 

TWO

 StarGuide II

and/or III, Wegener Unity 4000, ComStream or Scientific-Atlanta ENCORE, DSR-3610,
AD-4595 receivers.  The DSC-20 provides a convenient means of service/ providers
/program /channel /switching these receivers with contact closures, open collectors,
or 5 volt TTL/CMOS logic.  When the 

DSC-20

 is controlled from a PC’s serial port,

twenty, forty-eight character ASCII strings are provided for the above-mentioned
receivers.  Custom programming of the 

DSC-20

 is accomplished with a 

NON-

DEDICATED

 computer.

Features:

 Twenty – forty-eight character printable ASCII serial strings in

both the PC and/or contact closure (GPI) mode 

 Audio channel

swapping, service, provider, frequency and data rate control for the
StarGuide II / III receivers 

 Selection of active receiver ports

 Power and data activity LED’s 

 Non-volatile program memory

 Two - 9600 baud RS-232 receiver serial ports 

 9600 baud RS-232

or RS-485 network PC control and programming serial port (either
locally or remotely via optional modem) 

 Password / ID option

NOTE:  More than two receivers may be controlled by adding the
optional SDD-8 serial data director.

Applications:

Dual

 

contact closure

 

and/or PC serial control of the “StarGuide II

and/or III”, Wegener Unity 4000 or ComStream type receivers.

StatGuide II note

The DSC-20 in the (SG) “StarGuide II and/or III” mode will switch services only

after the network has authorized the receiver.  Please refer to your receiver manual for
instructions on verifying the services authorized.  If you have questions about your
network services, please contact your network provider.

Unpacking and Handling

Please examine your

  DSC-20

  for any damage that may have been sustained

during shipping.  If any is noted, please notify the shipper immediately.  Retain the
packaging for inspection by the shipper.  The package should contain the

 DSC-20,

 9vac

wall power transformer, Installation manual, Female 25 pin D-sub connector and shell,
3 - modular cables, 1 - 9 pin female “S-9” D-sub and 2 – 9 pin male “V-9” D-sub serial
modular adapters.

Содержание DSC-20

Страница 1: ...ced or distributed without permission SG Virtex StarGuide II or III are of StarGuide Digital Networks Inc Wegener Unity 4000 is a of Wegener Communications Premiere is a of Premiere Radio Networks ABC...

Страница 2: ...or inappropriate use and or installation could result in a hazardous condition Broadcast Tools Products as any electronic device can fail without warning Do not use this product in applications where...

Страница 3: ...D s Non volatile program memory Two 9600 baud RS 232 receiver serial ports 9600 baud RS 232 or RS 485 network PC control and programming serial port either locally or remotely via optional modem Passw...

Страница 4: ...8 Receiver 2 on the DSC 20 and the other end to the male 9 pin D Sub to modular adapter labeled V 9 Step 2 Plug the male D Sub modular adapter labeled V 9 into the M C connector on the rear of the Sta...

Страница 5: ...Dual 6 NOTE 1 CNN E NEWSLINK Dual 7 NOTE 1 CNN W NEWSLINK Dual 8 NOTE 1 DATS 07 08 Dual 9 NOTE 1 MBS E NEWSEVNTS Dual 10 NOTE 1 MBS W NEWSEVNTS Dual 11 NOTE 1 NBC E NEWSEVNTS Dual 12 NOTE 1 NBC W NEW...

Страница 6: ...ESTING YOUR STARGUIDE RECEIVER WITH YOUR COMPUTER S SERIAL COM PORT Tool Tip This step is required to confirm that the communication program and StarGuide II III receiver are configured properly The f...

Страница 7: ...indow open labeled with the Connection Description you typed in earlier in our example BTI96 At this window 1 Click on the word FILE at the upper left portion of the menu bar and click on Properties i...

Страница 8: ...ayed 5 If your test was successful remove the Male Female DB 9 straight through serial cable from the computer and receiver proceed to the section labeled Connecting the DSC 20 to your computers seria...

Страница 9: ...d that a failure is traced to the receiver and ALL receiver troubleshooting has failed contact the receiver manufacture Connecting the DSC 20 to your computers serial port Connect one end of the suppl...

Страница 10: ...ter store for this adapter After you have made your modem connection follow the same procedure as if you were operating the unit locally Password ID Programming Step 1 Hold down SW 1 at power up while...

Страница 11: ...ress the space bar ONCE and the configuration menu will appear Step 4 Enter number 5 to modify the StarGuide II and or III table data for Recvr port 1 or 6 to modify Recvr port 2 Step 5 Enter the loca...

Страница 12: ...nd or III Wegener Unity 4000 MM Channel number cr Carriage return End of string DO IT Examples w No Password 1V01 cr Selects Variable StarGuide II and or III Wegener Unity 4000 01 on Recvr port 1 2V01...

Страница 13: ...io mode code 0 1 2 or 3 04 _________________________ Audio port A through F 05 ____________________________ Audio mode command 06 _______________________________ Carriage Return 07 ___________________...

Страница 14: ...Inc Page 14 ABC network string examples SP A P 1 enterSP A S 19 enterAM A 0 enterenter String for ABC NY WOR 1 WOR 2 with normal audio SP A P 2 enterSP A S 18 enterAM A 0 enterenter String for ABC New...

Страница 15: ...ATS 14 DATS 15 5 SP C S 5 AM C 0 MARKETWATCH MISC 6 SP C S 6 AM C 0 TALK 7 TALK 8 7 SP C S 7 AM C 0 CBS 40 CBS VC 27 SP C S 27 AM C 0 CBS 41 CBS 43 8 SP C S 8 AM C 0 CBS 42 CBS 44 22 SP C S 22 AM C 0...

Страница 16: ...5 Mono SP x S 5 Premiere Three 3 19 Mono SP x S 19 Premiere Four 3 21 Mono SP x S 21 Premiere Five 3 20 Mono SP x S 20 Premiere Six 3 16 Mono SP x S 16 Premiere Seven 3 27 Mono SP x S 27 Premiere Eig...

Страница 17: ...ic active low J 3 Power connector 2 1mm coaxial 9 volt AC 500 ma w Green LED Wall Wart transformer supplied J 5 COMPUTER connector RJ 11 6P4C Data rate COMPUTER port 9600 8N1 RS 232c or RS 485 J 7 REC...

Страница 18: ...ce paid by the Buyer for the item Broadcast Tools shall have the exclusive right to choose between these alternative remedies NO OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BY APPLICA...