AVR-8 Installation and Operation Manual
DESCRIPTION
PRODUCT DESCRIPTION
The AVR-8 is a voice remote control system that automatically reports changes
detected on any one of its eight digital inputs to a remote telephone and/or pager.
After speaking a greeting message that may identify the source of the call, the AVR-
8 then speaks a unique message for each input change. Each message comes facto-
ry programmed, but may easily be re-recorded with your own customized messages.
After reporting, the AVR-8 is ready to receive commands through your telephone
keypad. Functions include telling the AVR-8 to report on the input state of any of
the eight digital inputs, commanding the AVR-8 to pulse any one of its four SPDT
relays for 750 ms and/or turning any one of the relays on or off. When a relay com-
mand is given, the AVR-8 speaks the relay 'name' followed by the 'on' or 'off' mes-
sage. For instance, commanding relay 4 on causes the AVR-8 to turn the relay on
and then report "Relay 4 ... is on." As with the greeting and input messages, the relay
'name', 'on' and 'off' messages may be re-recorded if desired.
In addition to initiating a call out when inputs change, the AVR-8 monitors its tele-
phone line to receive a call-in from a remote location. When a call is received, the
AVR-8 speaks a greeting message, and is then ready to receive and execute com-
mands to report on its inputs, or change to its relay outputs.
APPLICATIONS
Silence Monitor III alarm notification, Tower Light malfunction and/or operation,
Transmitter site and Studio security/burglar/fire/equipment alarm notification,
Inexpensive remote control system, Remote reset of file server computers, Station
ID playback, PA system announcing or Store Casting.
INSPECTION
Please examine your AVR-8 carefully for any damage that may have been sustained
during shipping. If any is noted, please notify the shipper immediately. Retain the
packaging for inspection by the shipper. The package should contain the AVR-8,
this manual, 7 foot modular cable and the 12 VAC @ 1 Amp transformer.