Audio Sentinel
®
+ Streaming Installation and Operation Manual
SETUP
Silence Sensors
Silence Sensors:
Use this drop down menu to choose a silence sensor to con-
figure.
Alarms Silent:
This option enables the generation of an alarm message when
silence is detected/restored.
Alarms Active:
This option enables the generation of an alarm when a chan-
nel is made active via front panel/web controls, automatic
switching, or remote control.
Email Addresses:
This allows you to assign up to 8 email addresses to send
alarm emails to whenever the input enters or exits an alarm
state.
Input Label:
Text label describing the input source. This is used on the
Monitor/Control page and in alarm log and email messages.
Delay (seconds):
Specifies the delay time from when the input value is below
the silence trip level and an alarm is generated.
Restore (seconds):
Specifies the delay time from when the input value is returns
to a level above the silence trip level and the alarm condition
is exited.
Trip Level (dB):
The input level below which the input is considered silent, in
dB below 0 dBu. Range: -12 to -35 dB.
Dual-mono mode:
When dual input mono mode is selected, both the left and
right inputs must be below the trip level before the input is
considered silent.
Log Device:
Enables the email snapshot logging of the input.
NOTE:
After any item has been
changed, you MUST
press the “Save
Settings” button for
your changes to be
saved.