Field #27: Transmission Mode, and Pre-emphasis Setup
MODE/PREEMPH. SETUP
STEREO PR 75
μS
The transmission "modes" (MONO R, STEREO, MONO L+R, EXT MPX), and the pre-emphasis time-
constants (0, 25, 50 or 75
μ
S) are set up here. The pre-emphasis is only active on audio channels and
not an external multiplex signal.
Set pre-emphasis to the correct standard for your area. Countries in North and South America use 75
μ
S pre-emphasis, while Europe and some other countries will use 50
μ
S
•
Field #28: Reference Deviation setup
REFERENCE DEVIATION
75 kHz
.The field selects the deviation to reference 0dB of modulation. The standard (default) is 75kHz but
you can choose any value between 5 and 75kHz, and specifically 50, 40 or 25 kHz.
•
Field #29: Display Contrast setup
DISPLAY CONTRAST
SETUP 5
It is possible to vary the display contrast. The setting range is 0 to 7 .
•
Field #30: Time & Date setup
DATE & CLOCK SETUP
31 JAN 21 12:45:00
This field edits date or time. The clock is configured for 24 hour clock time.
•
Field #31: Elapsed Time
ELAPSED TIME
000356 HOURS
This field shows the elapsed time of service whether the transmitter is on the air or in stand-by and
begins counting when AC mains are applied. This is set in the factory and is not a setting that can be
changed.