27
©2021 Broadcast Electronics
•
OPERATION MENUS
•
Field #02: Direct & Reflected Power
Pd 20W Pr .2 W
XXXX |
This field shows the forward or “direct” power, Pd, and the reflected power, Pr, in the VHF models.
Transmitter models in the SHF band will not show the reflected power as a circulator is used in the
final RF amplifier stage in this band.
•
Field #04: Multiplex Signal Level (Output Modulation)
MPX 75.0kHz + 0.0dB
#############
|
This field shows the actual peak modulation level in dB referenced to the peak deviation in kHz. A
pseudo-analog moving bar functions as a modulation meter, leaving a peak mark at its end for 1 or 2
seconds. A vertical bar (|) on this line marks the 0dB position.
•
Field #05: Left & Right Signal Level in dB
LEFT level - 3.0dB
RIGHT level - 3.5dB
This field shows the actual left and right peak modulation in dB referenced to 75kHz. The right
channel level has no meaning in the absence of an internal stereo-encoder.
The reading is fairly accurate with real audio signals. Some steady state test tones, especially at very
low audio frequency, may beat with the discrete ADC conversion sometimes producing reading
uncertainty (
aliasing
). In this case the MPX level reading will still correct overall modulation
measure.
•
Field #06: L & R Signal Level / Analog Meter
L########### O |
R######### O |
This field shows the actual left and right peak modulation as two moving bars. A vertical line marks
0dB position and the same considerations as in the previous menu are still valid.
Содержание Marti GRX