background image

10

8-Port DC Power Manager User Manual (PS-8DC-5V/12V/24V/48V)

 TELNET CONTROL

BUTTON CON-

FIGURATION

ON THE TOP MENU 

BAR CLICK ON CUS-

TOMIZE AND THEN 

CLICK ON 8/16 

BUTTON  KEYPAD.  

Before attempting to use Telnet control, please ensure that both the unit and the PC/Laptop 
are connected to the same active network.

To Access The Command Line Interface (CLI)

In Windows 7

Click 

Start

, type “cmd” in the search filed and press 

Enter.

In Windows XP Click 

Start

, > 

Run

 type “cmd” in the search filed and press 

Enter.

In Windows 7

Click Go > 

Applications 

Utilities 

Terminal.

Upon accessing the Command Line Interface (CLI), type “telnet” followed by the IP address 
of the unit (and the port number if it is non-standard) and hit the “Enter” key. See below for 
reference.

This will establish communication to the desired unit to control. Type “help” to list the 
available commands.

Note: The unit’s default IP address is 192.168.1.50. If the IP address is changed then the IP 
address required for Telnet access will also change accordingly.

Содержание PS-8DC-12V

Страница 1: ...ibed herein without prior notice or consent No liability is assumed as a result of their use or application All rights reserved 2019 Broadata Communications Inc PS 8DC 5V PS 8DC 12V PS 8DC 24V PS 8DC 48V USER MANUAL 8 Port DC Power Supply Manager 5V 12V 24V 48V ...

Страница 2: ... THE FOLLOWING SAFETY PRECAUTIONS SURGE PROTECTION DEVICE RECOMMENDED This product contains sensitive electrical components that may be damaged by electrical spikes surges electric shock lightning strikes etc Use of surge proctection system is highly recommended in order to protect and extend the life of your equipment ...

Страница 3: ...ur dealer In case liquid spillage on device unplug mains power cord and contact your dealer Continuous use in this case may result in fire or electric shock To reduce the risk of electric shock do not touch connectors with wet hand Only power with the marked voltage on the device Any other voltage can cause fire or electric shock Do not use the device if an abnormality occurs If any smoke or odor ...

Страница 4: ...ERATION CONTROL AND FUNCTIONS FRONT REAR PANEL RS 232 SERIAL CONTROL RS 232 TELNET COMMANDS WEB GUI CONTROL CONNECTION DIAGRAM SPECIFICATIONS SERVICE PROCEDURE REPLACEMENT POLICY RETURN AND REPAIR SERVICE LIMITED WARRANTY 5 6 6 8 9 11 18 19 20 20 20 21 1 0 2 0 2 1 3 0 4 0 5 0 5 1 5 2 6 0 7 0 7 1 8 0 ...

Страница 5: ...r input each power output current fan speed and system temperature is provided to give a comprehensive system overview FEATURES Power management system providing voltage controlled current 5V 12V 24V or 48V on each output Battery backed up clock for scheduling power events Integrated WebGUI for control and power analysis Unit s overall maximum power consumption is only 140 watts Supports 8 power o...

Страница 6: ...ingle gang electrical box or mud ring ISP RESET This button has multiple functions see below ISP MODE Press and hold this button while powering the unit on to enter ISP mode This mode is for firmware upgrage FACTORY RESET Press and hold this button for 5 seconds after the unit is already powered on to perform a full factory reset of the unit REBOOT Momentarily press this button after the unit is a...

Страница 7: ...t is disabled its LED will turn off 12V FAN A B Connect to a dedicated dual fan power and control cable Fan speed can be controlled via WebGUI Telnet or RS 232 SERV This slot is reserved for firmware update use only CONTROL Connect directly or through a network switch to your PC laptop to control the unit via Telnet WebGUI DC 12V Plug the 12V DC power adapter into the unit and connect it to an AC ...

Страница 8: ...2V 24V 48V 8 SERIAL CONTROL UNIT PIN DEFINTION 1 NC 2 TXD 3 RXD 4 NC 5 GND 6 NC 7 NC 8 NC 9 NC REMOTE SYSTEM PIN DEFINTION 1 NC 2 RXD 3 TXD 4 NC 5 GND 6 NC 7 NC 8 NC 9 NC Baud Rate 19200bps Data Bits 8 Parity Bits None Stop Bits 1 Flow Control None ...

Страница 9: ... ENABLE OR DISABLE POWER OUTPUT N1 N1 1 8 PORT NUMBER N2 ON OFF PWR N1 NAME N2 RENAME POWER OUTPUT N1 N1 1 8 PORT NUMBER PWR_STATUS N1 SHOW THE CURRENT POWER STATE VOLTS WATTS AMPS N1 1 8 PORT NUMBER N2 NAME STRING 16 CHARACTERS MAX TEMPERATURE SHOW DETAILS OF THE UNIT S TEMPERATURE AND FAN CONTROL SETTINGS FAN SET N1 SET NON AUTO MODE FAN SPEED OR ENABLE FAN AUTO MODE AVAILABLE VALUES FOR N1 0 10...

Страница 10: ...filed and press Enter In Windows XP Click Start Run type cmd in the search filed and press Enter In Windows 7 Click Go Applications Utilities Terminal Upon accessing the Command Line Interface CLI type telnet followed by the IP address of the unit and the port number if it is non standard and hit the Enter key See below for reference This will establish communication to the desired unit to control...

Страница 11: ...in a PC laptop where you can easily find it Connect the unit and the PC Laptop to the same active network and execute the Product Discovery Tool Click on the dropdown bar in the Select a unit to configure field and a list of devices connected to the local network will show up Select the desired device Click on the dropdown bar in the Select a configuration task field Select Set IP Address and clic...

Страница 12: ...V 24V 48V WEB GUI CONTROL In the next section the IP Address field will display the assigned IP address of the desired device Copy the IP address and paste it to the address bar of your internet browser Note The unit s default IP address is 192 168 1 50 ...

Страница 13: ...ng the appropriate user name and password Default username and password admin All primary functions of this unit are controllable via the built in WebGUI including Status Device Settings Schedule and System Settings The individual functions will be introduced in the following section Status This tab displays the current status of the various components of the unit in real time ...

Страница 14: ...ntrol over the optional external fans speed and temperature thresholds 1 Power Out This section provides control over each individual power output The outputs may be turned on turned off and renamed 2 Fan Setting This section provides controls for any connected fans When Auto Fan Mode is enabled the fan speed will be controlled based on the three user defined temperature thresholds and speed selec...

Страница 15: ...he Schedule tab provides multiple ways to automate and schedule the powering on and off of any of the 8 power ports on this unit 1 Repeat Mode Items in this section will execute at their set times on the selected days Sunday through Saturday every week as long as they are marked as Active ...

Страница 16: ...tomatically change to None Active after they have been executed once Note Each schedule item must be set as Active in order for it to activate at the desired scheduled time System Settings This tab provides system configuration options including changing the network settings downloading restoring saved system configurations modifying the username and password system time setting and updating the f...

Страница 17: ...he username is admin and the default password is also admin 3 System Time This section allows user to set the system time and date Note The new setting will not take effect until Save is clicked 4 Download Current Configuration This section allows the user to download the current system configuration to a local PC for restoration later 5 Restore Configuration This section allows user to restore a ...

Страница 18: ...8 Port DC Power Manager User Manual PS 8DC 5V 12V 24V 48V 18 CONNECTION DIAGRAM Note 5V Power Manager Pictured ...

Страница 19: ...ter for PS 8DC 24V 48 VDC Power Adapter for PS 8DC 48V Power Cord x 1 2 pin Terminal Block to DC Power Adapter Cable x 8 Fan Power Control Cable x 1 3 2mm to 9 pin D sub Adapter Cable x 1 CONTROL PORTS Ports Ethernet RS 232 USB A Service Port OUTPUT PORTS Ports 2 pin Terminal Block x 8 4 pin Terminal Block x 1 For Fan RS 232 Signal Format RS 232 Baud Rate 19200 bps Connector 3 5mm Input Jack STATU...

Страница 20: ...viceable components If you have a problem with your unit please contact the Customer Service Department To facilitate our return repair processing please contact Broadata Communications Inc to obtain a Return Material Authorization RMA Please include the following information Product Model Number Serial Number Complete Description of Problem Hardware Installation Description Broadata Communication...

Страница 21: ...or failure resulting from misuse abuse neglect alterations electrical power problems usage not in accordance with product instructions improper installation or damage determined by BCI to have been caused by the Buyer or repair made by a third party Limited warranties granted on products are to the initial customer end user and are not transferable OUR LIABILITY UNDER THIS WARRANTY SHALL IN ANY CA...

Страница 22: ...nications Inc 2545 West 237th Street Suite K Torrance CA 90505 1 800 214 0222 310 530 1416 310 530 5958 Facsimile e mail Sales Broadatacom com Website www broadatacom com 2545 West 237th Street Torrance CA 90505 800 214 0222 310 530 1416 e mail Sales broadatacom com www broadatacom com ...