API COMMANDS (RS232 & TELNET)
HDBaseT 18G/4K Multi-Format Presentation Switch w/ 5 Inputs and 2 Mirrored Outputs User Manual (LBC-PSW52)
#
Command
Description
84
S OSD-V-POS x
Set OSD vertical position.
x = 0~100
85
R OSD-V-POS
Read OSD vertical position.
86
S OSD-TIMER x
Set OSD automatic off time.
x =10~100 (seconds)
87
R OSD-TIMER
Read OSD automatic off time.
88
S OSD-TRANS x
Set OSD transparency.
x =0~100
89
R OSD-TRANS
Read OSD transparency setting.
90
S OSD-DISPLAY x
Set OSD display mode.
x = 0~2
0=Off
1=Info
2=On
91
R OSD-DISPLAY
Read OSD display status.
92
S IP-MODE x
Set IP mode.
x = 0, 1
0=Static 1=DHCP
93
R IP-MODE
Read IP mode.
94
S IP-ADDR x.x.x.x
Set IP address.
x =000~255
Note: The IP address cannot be
manually set when in DHCP mode.
95
R IP-ADDR
Read the current IP address.
96
S GATE-WAY x.x.x.x
Set gateway.
x =000~255
97
R GATE-WAY
Read gateway.
98
S SUB-NET x.x.x.x
Set subnet mask.
x =000~255
99
R SUB-NET
Read subnet mask.
100
S UDP x
Set UDP port.
x =1~65535
101
R UDP
Read UDP port.
102
R MAC-ADDR
Read MAC address.
103
S EDID-FROM x
Set the EDID copy source.
x = 0~3
0=None
1=Out1
2=Out2
3=Default