background image

LB-KP8E

L

INK

 B

RIDGE

TM

 8-B

UTTON

W

ALL

 P

LATE

 E

THERNET

 C

ONTROLLER

BCI reserves the right to make changes to the products described herein without

prior notice or consent. No liability is assumed as a result of their use or

application.  All rights reserved.

©2013 Broadata Communications, Inc.

Содержание LB-KP8E

Страница 1: ...ETHERNET CONTROLLER BCI reserves the right to make changes to the products described herein without prior notice or consent No liability is assumed as a result of their use or application All rights...

Страница 2: ...IANCE DECLARATIONS PLEASE OBSERVE THE FOLLOWING SAFETY PRECAUTIONS SURGE PROTECTION DEVICE RECOMMENDED This product contains sensitive electrical components that may be damaged by electrical spikes su...

Страница 3: ...LNET CONTROL 9 2 5 WEBGUI CONTROL 10 2 5 1 MACRO SETTINGS 11 2 5 2 EXTENSION MACRO 14 2 5 3 COMMAND SETTINGS 15 2 5 4 DEVICE SETTINGS 16 2 5 5 KEY SETTINGS 17 2 5 6 SCHEDULE 18 2 5 7 NETWORK SETTINGS...

Страница 4: ...oft and colorful LED design fitting all environmental purposes and PoE Power over Ethernet function ease power supply issue without extra DC power burden Further relay output design and scheduling fun...

Страница 5: ...troller Broadata Technical Support 800 214 0222 6 2 0 OPERATION CONTROLS AND FUNCTIONS 2 1 Front Panel 1 1 8 Macro Buttons Each button has 2 colors of LEDs adjustable from dim 0 100 and can have up to...

Страница 6: ...gnal that supports relay function 2 Control Connect from PC Laptop with active internet service or Telnet or WebGUI control with RJ 45 terminated cable This slot supports PoE PD 48V function which mea...

Страница 7: ...LB KP8E User Manual Link BridgeTM 8 Button Wall Plate Ethernet Controller Broadata Technical Support 800 214 0222 8 2 3 Telnet Commands...

Страница 8: ...n the Start menu and type cmd in the Search field then press enter Under Windows XP go to the Start menu and click on Run type cmd with then press enter Once in the command line interface CLI type tel...

Страница 9: ...tive network system open a web browser and type device s IP address on the web address entry bar A security page will appear to ask for User and Password please key in admin for both to enter Note The...

Страница 10: ...the function of lighting LEDs Macro 1 Light up the Red backlight LED with 100 brightness sequentially from 1 8 with every 500ms Macro 2 Light up the Blue backlight LED with 100 brightness sequentially...

Страница 11: ...and delete button is to delete the command Click on Insert button Add to insert commands Command can be set to control the Wall Plate Control Box SysCMD other devices connected within the same Telnet...

Страница 12: ...ice within the same telnet system or internet area require to set its IP and Port number and it is strongly recommand to set the delay time 500ms in order to secure a successful command sending Once t...

Страница 13: ...KP8E User Manual Link BridgeTM 8 Button Wall Plate Ethernet Controller Broadata Technical Support 800 214 0222 14 2 5 2 Extension Macro Click on Extension Macro to execute edit up to 8 more Macro acti...

Страница 14: ...sert new commands or delete commands A maximum of 128 commands are supported each command is less than 128 characters including spaces Alternatively up to 32 commands each command greater than 128 cha...

Страница 15: ...ate Ethernet Controller Broadata Technical Support 800 214 0222 16 2 5 4 Device Settings Click on Device Settings to setup the IP Address of a device Click on Edit to add a new device to be controlled...

Страница 16: ...configure the repeat or toggle setting of a key If Repeat is set to On pressing and holding the key causes the programmed macro to be repeated If Toggle is set to On pressing the key the first time ex...

Страница 17: ...a Technical Support 800 214 0222 18 2 5 6 Schedule Click on Schedule to set the executing time schedule of the Macro s Note The scheduling system supports up to 48hrs of memory under power blackout af...

Страница 18: ...Manual Link BridgeTM 8 Button Wall Plate Ethernet Controller Broadata Technical Support Sales Broadatacom com 19 Click on Edit from Repeat column to set the macro command s to be activated repeatedly...

Страница 19: ...8E User Manual Link BridgeTM 8 Button Wall Plate Ethernet Controller Broadata Technical Support 800 214 0222 20 Click on Edit from Once column to set the macro command s to be activated on a set time...

Страница 20: ...21 2 5 7 Network Settings Click on Network Settings to reset the IP Netmask or Gateway address 2 5 8 System Settings Click on System Settings to reset the WebGUI login password and timeout setting an...

Страница 21: ...0222 22 2 5 9 Time Settings Click on Time Settings to set the system time and to enable disable Daylight Saving Time DST function Simply click on the white column and a calendar will appear for your...

Страница 22: ...at 1 800 214 0222 for further assistance For electrical problems perform the following troubleshooting procedures 1 If the POWER indicator is OFF check for the following a The line cord is plugged in...

Страница 23: ...nk BridgeTM 8 Button Wall Plate Ethernet Controller Broadata Technical Support 800 214 0222 24 c Cable connections at both channels are securely fastened to each connector Turn the power off then back...

Страница 24: ...ta Technical Support Sales Broadatacom com 25 4 0 SPECIFICATIONS I O CONNECTORS Keypad 8 buttons I O Ethernet 1 RJ 45 Relay 1 Terminal Block PHYSICAL Dimensions W x H x D 3 62 x 4 07 x 1 50 Operating...

Страница 25: ...em contains no user serviceable components If you have a problem with your unit please contact the Customer Service Department To facilitate our return repair processing please contact Broadata Commun...

Страница 26: ...not include malfunctions or failure resulting from misuse abuse neglect alterations electrical power problems usage not in accordance with product instructions improper installation or damage determi...

Страница 27: ...LB KP8E User Manual Link BridgeTM 8 Button Wall Plate Ethernet Controller Broadata Technical Support 800 214 0222 28...

Страница 28: ...data Communications Inc 2545 West 237th Street Suite K Torrance CA 90505 1 800 214 0222 310 530 1416 310 530 5958 Facsimile e mail CustomerService Broadatacom com Website www broadatacom com 60000 LB...