Figure 12.
CAN NODE ADDRESS Jumpers
WARNING: CAN BUS Wiring
The CAN NODE ADDRESS jumpers are used to set the address of each board
on the CAN BUS. DO NOT ASSIGN TWO BOARDS THE SAME ADDRESS, OR
THE BUS WILL NOT FUNCTION PROPERLY.
Set these values sequentially, starting with 2 as the first expansion board
address; address 1 is the MAIN BOARD. Record all addresses on the
Installation Worksheet. These jumpers settings will map to board numbers
when the control panel is configures in the application.
Ignore the AEN Port
WARNING: AEN Port
DO NOT CONNECT THE AEN PORT FOR ANY REASON.
This will significantly
interfere with the function of the external network.
If instructed by Technical Support, connect a laptop to the MAIN BOARD
Figure 13.
Connect Laptop to MAIN BOARD
1.
Connect a laptop to the ADMIN port on the MAIN BOARD according to the Networking Admin
Interface Guide, using a standard Ethernet cable or a patch cable.
a)
The ADMIN port is a 10/100 Ethernet interface with RJ45 jack for connecting the
MAIN BOARD to a laptop or PC to gain access to the local administrative interface for
debug and manual configuration utilities.