2.  Wire the DOOR LOCK RELAY terminal block. 

a)  Connect the door latch to the COM terminal and either the NO or NC terminal. 

b)  The DOOR LOCK RELAY provides both NO (Normally Open) and NC (Normally 

Closed) contacts, and is driven in response to the presentation of valid 
credentials or the programmable REX input. 

c)  Timing and other aspects of relay activation are programmed through ACS 

Online. 

d)  The relay is rated at 3A at 125VAC. 

3.  If used, wire the DOOR LOCK 250MA terminal block. 

 

 

WARNING: AEN Port 

THIS TERMINAL BLOCK IS A VOLTAGE SOURCE; DO NOT APPLY EXTERNAL 
BATTERY. 

 

a)  The DOOR LOCK 250MA terminal block may be used to directly drive a door 

latch that operates at no more than12V and uses 250 mA or less. 

b)  Directly wire the door latch in a manner that observes the polarity requirements 

of the device. 

c)  This output is driven by the same logic that drives the standard door lock relay, 

described above. 

4.  If used for an alarm shunt, wire the AUX RELAY terminal block. 

a)  The AUX RELAY terminal block can be used for a variety of purposes, such as 

alarm shunting, and is programmed via ACS Online. 

b)   The fully programmable AUX RELAY provides both NO (Normally Open) and 

NC (Normally Closed) contacts. 

c)  The relay is rated at 3A @ 125VAC. 

5.  If used, wire the AUX INPUTS terminal block. 

a)  The IN1 and IN2 terminals are contact closure type inputs that share a COM 

terminal. 

b)  The terminals can be used for a variety of purposes, and are programmed 

through ACS Online. 

6.  If used, wire the AUX OUTPUTS 250MA terminal block. 

a)  The OUT1 and OUT2 outputs provide up to 25mA of current at +12V to power 

external relays or other devices. 

b)  The outputs are programmed via ACS Online. 

c)  Wire the Reader switches to the last block of terminals in this door node.  

 

 

NOTE: Refer to the Wiring Guide for Brivo approved devices and connection 
diagrams.

 

Содержание ACS5000-E

Страница 1: ...Brivo Access Control System ACS Installation Manual DOCUMENT NUMBER ENG DOC 003 ACS5000 E ENG WI 001 ...

Страница 2: ...ch the receiver is connected Consult the dealer for help Documentation Disclaimer and Restrictions Information in this document is subject to change without notice and does not represent a commitment on the part of Brivo Systems LLC For the most up to date information visit www brivo com and click Dealers to gain access to the Extranet This document and the data herein shall not be duplicated used...

Страница 3: ... SUPPORT THE INSTALLATION 5 VERIFY SHIPPING CONTENTS 6 PLAN YOUR INSTALLATION 7 DECIDE WHERE TO INSTALL EACH CHASSIS 10 FOLLOW SAFETY PRECAUTIONS 10 ASSEMBLY PROCEDURES 12 ASSEMBLE AND MOUNT CHASSIS 12 CONNECT THE MAIN BOARD AND ALL EXPANSION BOARDS TO A POWER SUPPLY BOARD 13 CONNECT THE TAMPER SWITCH TO THE MAIN BOARD AND TO ONE BOARD IN EACH EXPANSION CHASSIS 14 CONNECT THE BATTERY LEADS TO THE ...

Страница 4: ...Brivo ACS Installation Manual ACS5000 E ENG WI 001 2005 Brivo Systems LLC All rights reserved Page 3 ...

Страница 5: ...ons provided below are the ones intended in this Installation Manual Control chassis The main chassis for a control panel The control chassis contains the MAIN BOARD and may also contain one expansion board either a DOOR BOARD or an INPUT OUTPUT BOARD Expansion chassis Additional chassis containing one or two expansion boards either DOOR BOARDs and or INPUT OUTPUT BOARDs Control panel The complete...

Страница 6: ...of the Wiring Guide If you have a specific model of reader or keypad that is not listed on the Brivo website please contact Technical Support at 1 866 BRIVO 4 U to determine the compatibility Verify that the client site is ready to support the installation 1 Check with the IT department to ensure that the ACS5000 E is compatible with the company s local area network LAN a The ACS5000 E is equipped...

Страница 7: ...s for power supply MCH SCW 0001 d 5 standoffs for the MAIN BOARD MCH SFF 0001 e 1 tamper switch assembly ELC TMP A001 f 1 documentation set including Installation Manual this document ENG WI 001 Wiring Guide ENG WI 002 Networking Guide ENG WI 003 attached to the end of this document Installation Worksheet ENG WI 004 Quick Start Guide ENG WI 005 2 If additional DOOR BOARDs have been ordered with th...

Страница 8: ...C transformer ELC XFM AMS1 Plan your installation 1 Determine the size of your control panel a In addition to the control chassis which contains the MAIN BOARD there may be up to seven expansion chassis b The control chassis contains the MAIN BOARD which also serves as a 2 door board and may also contain either a DOOR BOARD or an INPUT OUTPUT BOARD c Each expansion chassis may contain one or two b...

Страница 9: ...er it can be used in any circumstance that uses contact closure to track change of status 2 Using the packing slip as a guide complete the Installation Worksheet included with your documentation set NOTE The following copy of the installation worksheet is for reference purposes only Clean copies of the worksheet are available in PDF format on the Dealer Extranet ...

Страница 10: ...or Name EXAMPLE Control Panel ID Card Numbering HID Corporate 1000 2 HID 37 Bit with Facility Code 4 HID 37 Bit 3 Generic 34 Bit Odd Parity 4 Casi Rusco 40 Bit 3 HID 33 Bit 4 External First Internal 5 Facility Code Company ID Code Generic 34 Bit Even Parity 4 Board ID 2 16 Reader Type Has REX Door Ajar Threshold C K D B Invalid PINs Threshold Pass though Period Alarm Shunt Duration Enabled 30 600 ...

Страница 11: ...0 3 1450 4 1400 5 1350 6 1300 7 1250 8 1200 Table 1 Maximum Distance Calculations c Calculate the distance between each chassis and its associated keypad or reader The ACS does not specify a maximum distance between the chassis and a keypad or reader but the keypad reader manufacturer does Follow manufacturer guidelines for each keypad and reader d Place each chassis within 500 feet of its associa...

Страница 12: ... panel DO NOT INSTALL THE CONTROL PANEL NEAR OR ON THE SAME CIRCUIT WITH DEVICES THAT PRODUCE LARGE AMOUNTS OF ELECTRICAL NOISE This includes grinders electric motors and blowers electrical switch gear and other electrically noisy equipment Electrical noise can interfere with panel operation If it is not possible to install the panel away from such sources of noise it is advisable to isolate it by...

Страница 13: ...rcuit boards which could cause permanent damage Pry them out using a screwdriver 4 Assemble the chassis a Install the power supply board in each chassis first If you install the MAIN BOARD or a Door or INPUT OUTPUT BOARD first you may find it difficult to position your screwdriver in a way that will allow you to install the power supply board later b Install the MAIN BOARD in the control chassis I...

Страница 14: ...ect MAIN BOARD to Power Supply 2 If there is a DOOR BOARD or an INPUT OUTPUT BOARD in the control chassis connect that to the power supply board Figure 2 Connect Expansion Board to Power Supply 3 If there are expansion chassis connect each DOOR BOARD and INPUT OUTPUT BOARD to the power supply board in each chassis a Use the power cable that came with each circuit board kit b The Power connector us...

Страница 15: ... chassis 1 Connect the tamper switch to the MAIN BOARD in the control chassis Figure 3 Connect Tamper Switch to MAIN BOARD a The tamper header connects to the supplied tamper switch b The header connector for the tamper switch should be connected to the TAMPER pins located on the lower right side of the MAIN BOARD and each expansion board 2 Connect the tamper switch to one expansion board DOOR BOA...

Страница 16: ...onnect the battery wires ELC BAT W001 that come with each circuit board kit to the power supply BATTERY INPUT terminal block a Connect the black wire to the ground GND terminal b Connect the red wire to the 12V terminal Figure 5 Connect Battery Leads to Power Supply Wire the AC transformer to the power supply WARNING Transform Connection DO NOT CONNECT THE TRANSFORMER TO A SWITCHED OUTLET OR OTHER...

Страница 17: ...Systems LLC All rights reserved Page 16 Figure 6 Connect AC Transformer to Power Supply 1 Use 18 AWG wire minimum grade to connect the screw terminals on the transformer to the 16 VAC POWER INPUT terminal block on the power supply board using terminals AC1 and AC2 ...

Страница 18: ...indicators a Check the power supply board to confirm that the green LED is on and blinking indicating that AC power is being supplied to the board and that the board is producing 12 VDC power b Check the MAIN BOARD to confirm that the LOCAL HRTBT local heartbeat and MAIN HRTBT main heartbeat have come on and are blinking The local heartbeat should begin blinking immediately The main heartbeat can ...

Страница 19: ...ot come on or does not begin blinking check the connections from the power supply to each of the circuit boards If all connections are good but there is a still a problem with the power indicator contact Technical Support NOTE A steady light is an indication of a problem just as much as no light is 3 If ALL power indicators are correct attach the back up battery and check that ALL indicators remai...

Страница 20: ...ed Page 19 Installation Procedures Establish CAN BUS Wiring 1 If there is an expansion board in the control chassis connect it to the MAIN BOARD Figure 9 Connect Expansion Board to MAIN BOARD 2 If there are expansion chassis in each chassis connect the second expansion board to the first one ...

Страница 21: ...s in the control panel there would be a MAIN BOARD and five expansion boards E1 E2 E3 E4 and E5 Each expansion board could be either a DOOR BOARD or an INPUT OUTPUT BOARD b To daisy chain the boards together See Figure 11 below Wire E5 to E4 in Expansion Chassis 2 Wire E4 in Expansion Chassis 2 to E3 in Expansion Chassis 1 Wire E3 to E2 in Expansion Chassis 1 Wire E2 in Expansion Chassis 1 to E1 i...

Страница 22: ...he very last board s in the daisy chain i e It must be removed from all boards except the endpoint of the daisy chain NOTE The MAIN BOARD does not have to be an endpoint in the control panel the control panel may be in the middle of the chain with expansion boards branching out in either direction 7 On the first board connect the wires of the Cat 5 cable to the CAN BUS terminal block as follows a ...

Страница 23: ...ting with 2 as the first expansion board address address 1 is the MAIN BOARD Record all addresses on the Installation Worksheet These jumpers settings will map to board numbers when the control panel is configures in ACS Online Ignore the AEN Port WARNING AEN Port DO NOT CONNECT THE AEN PORT FOR ANY REASON This will significantly interfere with the function of the external network Connect a laptop...

Страница 24: ...t LAN to MAIN BOARD 1 Connect the LAN to the MAIN BOARD according to the instructions in the Networking Guide attached to this document a The LAN port is a 10 100 Ethernet interface with an RJ45 jack for connecting the MAIN BOARD to a Local Area Network in order for it to gain connectivity to the Internet and Brivo Central b Use a straight i e non crossover cable to connect this port to a local hu...

Страница 25: ...and suppress any Door Forced messages b Connect the Normally Closed NC contacts of the Door Sensor to the COM and CONTACT terminals In this context an NC switch is considered closed when the door is closed magnet is present and open when the door is open no magnet is present When the switch is open the control panel interprets this input as a Door Open condition When the switch is closed the contr...

Страница 26: ...erves the polarity requirements of the device c This output is driven by the same logic that drives the standard door lock relay described above 4 If used for an alarm shunt wire the AUX RELAY terminal block a The AUX RELAY terminal block can be used for a variety of purposes such as alarm shunting and is programmed via ACS Online b The fully programmable AUX RELAY provides both NO Normally Open a...

Страница 27: ...ader wire to the GND terminal This is the standard Ground circuit for the reader Connect the blue reader wire to the BUZZ terminal This is the standard Buzzer circuit for the reader Connect the red reader wire to the 12VDC terminal This provides 12VDC to power the reader Connect the orange reader wire to the GRN LED terminal This is the green LED circuit Connect the brown reader wire to the RED LE...

Страница 28: ...wired for line supervision Figure 17 EOL Resister Wiring WARNING Powering Electronic Strikes and Latches DO NOT POWER ELECTRONIC STRIKES AND LATCHES WITH THE BATTERY OR OTHER POWER SOURCE USED TO POWER THE CONTROL PANEL DOING SO WILL CAUSE DAMAGE TO THE BRIVO CONTROL PANEL USE ONLY A UL LISTED BURGLAR ALARM OR ACCESS CONTROL SYSTEM TO POWER ELECTRONIC STRIKES AND LATCHES Ground the control chassis...

Страница 29: ... 001 2005 Brivo Systems LLC All rights reserved Page 28 2 Use 18 AWG or larger wire to connect the chassis to a suitable earth ground 3 The ground contact point is in the lower panel area near the hinge for the door and in front of the power supply ...

Отзывы: