![background image](http://html.mh-extra.com/html/brivis/cc315in/cc315in_installer-manual_2814584007.webp)
4
300mm
Min
2.2 Service Clearances
Method 1 - In Ceiling & Under Floor
Method 2 - In Ceiling & Under Floor
2.3 Splitting Compact Classic Heaters
The Compact Classic model heaters can be split in half to allow for ease of installation. To split the heater, follow
these simple instructions:
•
Remove the four screws securing the roof and remove
•
Disconnect the main loom quick-connect plug located on the cabinet centre wall
•
Disconnect spark igniter from the control board and feed back into heat exchanger cabinet
•
Remove the two large metric screws above the controls securing the fan cabinet to the heat exchanger cabinet
•
Split the heater by firstly tilting then pulling the fan cabinet from the heat exchanger cabinet
•
To reassemble conduct the above in reverse order
Diagram 3.
Diagram 2.
Fan
Cabinet
Heat
Exchanger
Cabinet
800 mm
Minimum
Platform
Service Clearance
Heat
Exchanger
Cabinet
Fan
Cabinet
750mm
Minimum
Note:
All minimum service height clearances are to the underside of the rafters or any obstruction.
Fan
Cabinet
Heat
Exchanger
Cabinet
250 mm
Minimum
750mm
Minimum
Service Clearance
Platform
750mm
Minimum
Heat
Exchanger
Cabinet
Fan
Cabinet
300mm
Min