Rinnai 19
Ducted Gas Heater IM
3.9 SERVICE CLEARANCES
Brivis internal heaters installed within the roof space shall be installed on a platform with minimum “Service
Clearances” provided as detailed in Diagram 6. For more information regarding platform requirements refer to
Section 1.9 “Installation of Internal Heaters”.
Diagram 6.
3.10 SPLITTING CLASSIC 2PWN HEATERS
The Classic 2PWN model heaters can be split in two to allow for ease of installation. To split the heater, follow these
simple instructions:
• Remove the access panel located on top of the fan cabinet compartment by removing the two screws.
• Disconnect the fan motor loom active and neutral from the terminal block located inside the recess.
• Remove the fan motor loom earth terminal secured to the fan motor cabinet inside the recess.
• Remove the four screws, two screws on each side of the heater, fastening the fan cabinet to the heat exchanger
cabinet.
• The heater can now be split in two.
• Protect the exposed looms from damage while the heater is split in two parts.
• Once in position, reassemble in reverse order.
NOTE
Ensure when reassembling the heater that everything is put back and connected correctly.
Service
Clearance
Service
Clearance
750 mm
600 mm
60
0
m
m
750
m
m
Platform
P
la
tfo
rm
HEATER DIMENSIONS AND CLEARANCES