background image

CLEANING YOUR FIRE

Turn the fire off and allow it to cool before attempting any cleaning.
Normally the fire will only need dusting. The bright metal trims may be cleaned with a
damp cloth and dried with a soft duster. Obstinate marks can be removed from the guard
and trims using soapy water. 

Never use abrasive cleaners.

The radiants can be cleaned with a soft brush - see the following section for removing
the radiants.

REPLACING THE RADIANTS

See figure 4.

Always use the correct type
of replacement radiant. Ask
for part number 5110472
Turn the fire off and allow it
to cool before attempting to
remove the radiants

.

Remove the dress guard by
pressing down the two hooks
at the top. Tilt the guard
forward and lift out.
Lift the radiant upward to clear
the metal retaining bar then
pull out bottom first.
Fit the new radiant by inserting
its top under the top lip of the
radiant box then swing the
bottom of the radiant over and
behind the retaining bar. 

It is important that the front face of the radiant should rest

against the front of the retaining channel.

Replace the dress guard. Locate the bottom

of the dress guard in the two holes in the bottom panel apron. Push the guard back so
that the two spring projections at the top of the guard engage in the slots under the front
decorative canopy.

Page 8

OWNER GUIDE

Figure 4.

Содержание Sunfire II Radiant 347

Страница 1: ...Convector Gas Fire Model 347 G C Number 32 032 62 THIS APPLIANCE IS FOR USE WITH NATURAL GAS G20 THIS APPLIANCE IS SUITABLE ONLY FOR INSTALLATION IN THE UNITED KINGDOM GB AND THE REPUBLIC OF IRELAND IE ONLY Manufactured exclusively for British Gas Scottish Gas by Valor Heating For Service Phone 0845 950 0400 ...

Страница 2: ...r is a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation The manufacturer is a CORGI registered company This gas fire must be installed by a competent CORGI Registered Installer in accordance with our Installer Guide and should not be fitted directly on to a carpet Valor Heating Erdington Birmingham B24 9QP w...

Страница 3: ...ance and features it has to offer SAFETY Do have the fire installed by a competent person In the United Kingdom installation must be in accordance with the latest edition of the Gas Safety installation use Regulations In the Republic of Ireland installation must be in accordance with all national and local regulations in force Do have the chimney swept prior to installation if it was previously us...

Страница 4: ...e acts as a fireguard conforming to BS1945 1971 and satisfies the Heating Appliance Fireguard Safety Regulations 1991 Do wait three minutes before attempting to relight if the fire is switched off or the flames are extinguished for any reason Your fire is fitted with a safety device that will automatically shut off the gas supply to the fire if for any reason the flames go out Do get advice about ...

Страница 5: ...o clean or service the fire until it has been switched off and allowed to cool completely Don t use the fire with damaged radiants APPLIANCE DIMENSIONS GAS CONSUMPTION Has a maximum natural gas input of 5 6kW Gross Has a maximum natural gas output of 4 0kW Has a minimum natural gas input of 1 57kW Gross Has a minimum natural gas output of 1 0kW Page 5 OWNER GUIDE Figure 1 Dimensions and clearances...

Страница 6: ...re The control is shown in figure 2 Depress the control knob slightly and turn anticlockwise towards the 1 IGN position Do not apply too much pressure as this will cause resistance to be felt Depress the control knob Sparks should be generated at the pilot The sparks should ignite the pilot If the pilot does not light turn the control knob back to the OFF position and try again The pilot flame can...

Страница 7: ... depressed light the pilot by inserting a long match or taper into the opening as in figure 3 When the pilot is alight keep the knob depressed for about ten seconds to allow the flame sensing probe to warm up before setting to your preferred heat level For your own convenience have the heater serviced as soon as possible Page 7 OWNER GUIDE Control Knob Position Radiants Condition 2 Centre radiants...

Страница 8: ...w it to cool before attempting to remove the radiants Remove the dress guard by pressing down the two hooks at the top Tilt the guard forward and lift out Lift the radiant upward to clear the metal retaining bar then pull out bottom first Fit the new radiant by inserting its top under the top lip of the radiant box then swing the bottom of the radiant over and behind the retaining bar It is import...

Страница 9: ...te causing the flue to be blocked or restricted and so preventing proper clearance of dangerous exhaust fumes In the United Kingdom it is the law that a landlord must have any gas appliance flue and pipework which is situated in a tenant s premises checked for safety at least every twelve months by a competent person In the U K a CORGI registered installer We recommend that all gas appliances and ...

Отзывы: