14.0 SERVICING
This appliance is supplied with a BS1363 3-pin plug
fitted with a 13 Amp fuse. Should the fuse require
replacing, it must be replaced with a fuse rated at
13 Amp and approved to BS1362. In the event of
the mains plug being removed/replaced for any
reason, please note :
The wires in the mains lead are coloured in
accordance with the following code:
Blue
Neutral
Brown
Live
Green/Yellow
Earth
As the colours of the wires in the mains lead of
this appliance may not correspond with the colour
markings identifying the terminals in your plug,
proceed as follows.
The blue wire must be connected to the terminal
marked with an N or coloured black. The brown
wire must be connected to the terminal marked
with an L or coloured red. The green/yellow wire
must be connected to the earth terminal which is
marked with an E or with the earth symbol.
NOTE:
If a moulded plug is fitted and has to be
removed take great care in disposing of the plug
and severed cable, it must be destroyed to prevent
engaging into a socket. Refer to Section 3.0,
Appliance Data for fuse specification. Excluding
fuses, use only genuine manufacturers spare parts
available from your supplier.
There are no internal
user serviceable parts.
My Electric Stive Fire...
Remedy
is not switching on
Ensure mains switch is on. Replace the fuse in the plug.
is not emitting any heat
The fire is fitted with an energy saving thermostat. If the
temperature in the room is higher than the temperature
selected on the fire, then the thermostat will stop the heater
from turning on. For example, if the room temperature is 22°C
or above and the fires heater is set at 22°C, then the heater
will not be required until the room temperature drops below
22°C. If this is the case select a higher temperature setting
than the room’s temperature and the heater will begin to
operate. The safety cut-out may have been operated. Switch
the appliance off, leave for two minutes then switch back on.
shuts off after a period of time
Check that the temperature is not set onto the lower settings.
If the room is warm enough the thermostat will stop the fire
switching the heat on.
Check that the chimney/flue is blocked off.
Check that the window detection sensor has not activated.
//
12.0 TROUBLESHOOTING GUIDE
//
WARNING:
Never connect live or neutral wires to the earth terminal of the plug.
//
13.0 SPARES
Refer to Section 3.0 Appliance Data for lamp and
fuse specification. Excluding lamps and fuses, use
only genuine manufacturers spare parts available
from your supplier.
//
15
//
16
© 2019 British Fires