Briteq STAGE BEAMER RGB Скачать руководство пользователя страница 21

19

5  

APPENDIX

No display

SITUATION

CAUSE

ACTION

5.1  

  

 TROUBLE SHOOTING

1) No power input

2) Power connection error

3) Display damaged

4) Display board IC error

or  power input 

    connection error

or two board connection 

    error

5) Contrast decay

1) Check power supply
2) Check power connection 
3) Replace  display
4) Check the IC and all the connections
5) Adjust the LCD contrast

1) Display IC reverse install
2) Display IC  damaged

1) Check Display IC installation and quality

LED MODULE 
on, but no control 
from display

Display normal, 
but no response 
from buttons

1) Buttons damaged
2) Display IC damaged

1 ) R e p l a c e   b u t t o n s
2) Replace Display IC

1) Signal Cable error
2) Signal conncetion error
3) The DMX signal receive IC damaged
4)  DMX address error

No DMX signal 

1) Check all signal Cables
2) Check all signal  conncetions
3) Check the DMX signal receive IC
4) Check DMX address

1) The heat sensor resistance of LED board 
      error
2) The temperature protection circuit on the 
      display error.

When the surface  
temperature of the 
unit exceed 75 , the 
temperature protection  
no work .

1) Replace the heat sensor resistance.
2) Check the temperature protection circuit.

1) Check LEDs joining
2) Check lens installing

1) LED not joining well
2) Lens not installing well

Color mixing 
uneven,with splash

1) LED damaged
2) LED damaged or Main PCB 

LEDs of the same
 color are not lit

1) Replace LEDs
2) Replace damaged LED or Main PCB

1) Replace saving IC

1) Saving IC damaged

Manual and program 
can not save

 

APPENDIX

1) Check driver current of the partial color 
     LEDs on the Driver PCB
2) Check LED quality 
3) Reset to factory default setting.

1) The current of one of the color group LEDs 
is too strong or too weak. 
2) LED brightness not enough

Partial color

partial red,partial 

green, partial blue
 or partial white

2009.11.10

Содержание STAGE BEAMER RGB

Страница 1: ......

Страница 2: ... 9 EDITING CUSTOM PROGRAMS 12 3 12 WHITES BALANCE 13 PART 1 PRODUCT GENERAL 1 1 1 PRODUCT INTRODUCTION 1 1 2 PRODUCT FEATURES 1 1 3 TECHNICAL SPECIFICATIONS 2 1 4 PHOTOMETRIC DATA 3 1 5 SAFETY WARNING 4 PART 2 INSTALLATION 5 2 1 MOUNTING 5 2 3 SETTING UP WITH ADMX512 CONTROLLER 6 2 3 1 DMX512 ADDRESSING WITHOUT ID ADDRESSING 6 2 3 2 DMX512 ADDRESSING WITH ID ADDRESS 6 2 2 POWER CONNECTION 5 3 3 ED...

Страница 3: ...ntrolled from any DMX512 controller This product can be operated as a single unit or in multiple units for large applications 1 2 PRODUCT FEATURES LED FIXTURE RGB Dimmer 0 100 Strobe Built in automatic programs Upload custom parameters to slave fixtures LED display Display control lock out Direct DMX512 input Independent ID address Different white colors setting Over heat protection 1 PRODUCT GENE...

Страница 4: ...IONS LED MODULE Dimensions LED MODULE Voltage Rated Power 14 X 3W Tri RGB Weight LED Unit Cooling Direct air convection 245 x 205 x 245mm 4 8Kg 100 250V 50 60Hz 52W 1 PRODUCT GENERAL 2 Environment Temperature 20 40 2009 11 10 ...

Страница 5: ...1 4 PHOTOMETRIC DATA 1 PRODUCT GENERAL 3 2009 11 10 ...

Страница 6: ...th wire must always be connected to the ground Do not touch the power cables if your hands are wet ATTENTION This product left the place of manufacture in perfect condition In order to maintain this condition and for safe operation the user must always follow the instructions and safety warnings described in this user manual Avoid shaking or strong impacts to any part of the equipment Make sure th...

Страница 7: ...he unit a safety cable should also be used 220V 24 units may be connected in series 120V 12 units may be connected in series The LED MODULE can be mounted at any angle and in any position It is possible to further adjust the angle of the LED MODULE using the two adjustment knobs located on the side of the fixture 2 2 POWER CONNECTIONS 5 2 INSTALLATION Note If the signal cable is over 60m between t...

Страница 8: ...deactivate ID address selecting ID OFF from the Settings menu on the fixture Each DMX Address may be used as many times as required Any DMX address in the range from 001 to 512 may be used 2 3 2 DMX512 ADDRESSING WITH ID ADDRESS TOUR MODE Connect the DMX512 controller to the units in series Each unit has 10 DMX channels so the DMX Addresses should increase by increments of 10 e g 1 11 21 31 Each D...

Страница 9: ...ree units have different ID addresses which allows the user to collectively control the whole group of units at that DMX address by setting CH10 to 0 or to control each unit independently by first selecting the DMX address and then by using Ch10 to locate the target ID address 7 2 INSTALLATION 2009 11 10 ...

Страница 10: ...elected menu or confirm the current function value scroll UP through the menu list or increase the value of the current function scroll DOWN through the menu list or decrease the value of the current function scroll through the main menu or return to the main menu MENU ENTER 2009 11 10 ...

Страница 11: ...3 DISPLAY PANEL OPERATION 9 3 2 MENU 2009 11 10 ...

Страница 12: ...of colors 0 255 Set the value of the Strobe 0 20Hz 3 4 ACTIVATING AUTO PROGRAMS AUTO Select the target AUTO program and press ENTER Programs AT 01 to AT 10 are fully pre programmed and will not be altered by changes in EDIT mode Programs PR 01 to PR 10 are fully pre programmed and can be edited in EDIT mode 2009 11 10 ...

Страница 13: ... DMX mode to set the DMX ADDRESS 11 3 DISPLAY PANEL OPERATION 3 7 PERSONALITY PERSONALITY Enter the PERSONALITY mode to select DMX mode TOUR Arc 1 Ar1 d Ar1 s or HSV 3 8 ID ADDRESS ID Enter the ID mode to set the ID ADDRESS 2009 11 10 ...

Страница 14: ...the MASTER and SLAVE units will display YELLOW If an error occurs when uploading the MASTER and or SLAVE units will display RED On successful uploading of the custom programs the MASTER and SLAVE units will display GREEN In order to reset custom modes to default values select REST Enter ID in order to allow disallow ID address function from the DMX512 controller COLOR is for activate unactivate th...

Страница 15: ...B CALIBRATION 3 13 ACTIVATE THE PASSWORD KEY Enter the KEY mode to select whether the access password is on or off When the fixture is set as PASS ON after 30 seconds or turn on the fixture next time the fixture will need an access password to enter the display menu control Note The factory access password is UP DOWN UP DOWN then press ENTER to confirm the access Enter Dim to select dimmer mode an...

Страница 16: ... all of the units in series using standard DMX512 signal cable or the IP65 rated cable provided Set the DMX512 address in the DMX menu It is possible to have the same DMX address or independent addresses for each fixture 4 2 CHANNEL ASSIGNMENT 14 4 USING A DMX512 CONTROLLER TOUR 4 USING A DMX512 CONTROLLER 2009 11 10 ...

Страница 17: ...15 4 USING A DMX512 CONTROLLER 2009 11 10 ...

Страница 18: ...16 4 USING A DMX512 CONTROLLER 2009 11 10 ...

Страница 19: ...17 4 USING A DMX512 CONTROLLER 2009 11 10 ...

Страница 20: ... CH4 CH5 CH1 is used to control the intensity of the COLOR MACRO STROBE CH 6 controls the strobe of CH1 to Ch5 ID ADDRESS SELECTION CH10 is used to select the target ID address Each independent DMX address may have upto 66 independent ID addresses An ID address of 0 will activate all ID address locations AUTO CH7 selects the preset AUTO programs AT 01 AT 10 or the custom AUTO programs CUS 01 CUS 1...

Страница 21: ...ignal conncetions 3 Check the DMX signal receive IC 4 Check DMX address 1 The heat sensor resistance of LED board error 2 The temperature protection circuit on the display error When the surface temperature of the unit exceed 75 the temperature protection no work 1 Replace the heat sensor resistance 2 Check the temperature protection circuit 1 Check LEDs joining 2 Check lens installing 1 LED not j...

Страница 22: ...20 5 APPENDIX 2009 11 10 5 2 MAINTENANCE ...

Отзывы: