background image

ENGLISH 

 

OPERATION MANUAL 

 

 
BRITEQ

®

 

4/23 

BTX-TITAN 

LAMP (RE)PLACEMENT 

In  case  of  replacement of the  lamp  or maintenance,  do  not  open the fixture within  10 
minutes  until  the  unit  cools  down  after  switching  off.  Always  unplug  the  unit  before 
servicing! Always use the same type of spare parts (bulbs, fuses, etc.) When replacing 
parts, please only genuine spare parts. 

 

Because of its high internal pressure, there might be a risk that the Discharge lamp would explode during 
operation. The lamp emits intense UV radiation which is harmful to the eyes and skin. The high luminance 
of the arc can cause severe damage to the retina if you take a close look at the lamp. 
To protect the lamp, always turn off the lamp first (via control panel or DMX controller) and let the unit run 
at  least  five  minutes  to  cool  down  before  switching  off  the  mains  supply.  Never  handle  the  lamp  or 
luminary when it is hot. 
Wear  gloves,  do  not  touch  the  bulb  with  bare  hands.  If  this  happens,  clean  the  lamp  with  denatured 
alcohol and wipe it with a lint free cloth before installation. 
When  lighting  up, the  lamp  operates  at high  pressure  and  there  is  a  slight  risk  of  arc  tube  rupture.  The 
risk increases with age, temperature and improper handling of the lamp.  
Do not use the lamp longer than its lifespan. 
Make sure the lamp is located in the center of the reflector for the best projection. 

 

  Switch off the unit and unplug the mains cable.  

  Wait for about 10 minutes until the unit has been cooled down. 

  Use a screwdriver to unscrew the screws (A-B-C) to open the back cover of the fixture.(Fig. 1) 

 

Figure 1 

– Back cover

 

 

Inside  you  will  find  the  OSRAM 

“Sirius  HRI  280W  E20.6”  lamp 

(Figure 2) 

 

 

Attention: 

wear gloves, do not touch the bulb with bare hands. If 

this  happens,  clean  the  lamp  with  denatured  alcohol  and  wipe  it 
with a lint free cloth before installation. Not doing this will shorten 
the life of the new lamp!

 

 

 
 
 
 
 

Figure 2 - OSRAM Sirius HRI 280W 

 

 

Содержание BTX Titan

Страница 1: ......

Страница 2: ......

Страница 3: ...ery fast 540 270 PAN TILT movements with 8 or 16bit precision Modular setup for easy servicing and cleaning Optional wireless DMX module available W DMX Sweden 2 8 Color touch screen with automatic di...

Страница 4: ...echanical safety in your country Check that the available voltage is not higher than the one stated on the rear panel of the unit The power cord should always be in perfect condition Switch the unit i...

Страница 5: ...andle 5 Pan self locking handle Caution the head and arm must be unlocked before operation Tilt mechanism locks and releases every 45 Pan mechanism locks and releases every 45 CONTROL PANEL 6 Wireless...

Страница 6: ...e the lamp or luminary when it is hot Wear gloves do not touch the bulb with bare hands If this happens clean the lamp with denatured alcohol and wipe it with a lint free cloth before installation Whe...

Страница 7: ...to unscrew any more scews to remove the lamp just GENTLY move the two metal parts that maintain the lamp in position Hold the lamp by the base during this operation Figure 4 Figure 4 Move the metal su...

Страница 8: ...s correctly the lamp Switch the unit back on and use a DMX controller to point the open beam on a wall Attention avoid looking at light coming directly from the lamp inside the unit the UV radiation o...

Страница 9: ...area can hold a minimum point load of 10times the device s weight Always use a certified safety cable that can hold 12 times the weight of the device when installing the unit This secondary safety att...

Страница 10: ...ignal Pin layout XLR 5pin Pin1 GND Pin2 Negative signal Pin3 Positive signal Pins4 5 not used To prevent strange behavior on the DMX units due to interferences you must use a 90 to 120 terminator at t...

Страница 11: ...kes installation easier because each product can be identified by a unique number With the internal battery no need to plug the power to set or read the fixture id To change the fixture id a password...

Страница 12: ...Press the ICON a list of error messages will apprear Please check the list of error codes at the end of the user manual SETTINGS MENU Press Settings on the display to open the setup menu Use the UP DO...

Страница 13: ...the center of the screen at least 2 seconds yellow progress bar appears on the screen and DMX Address panel appears DMX address can be modified with the slider on the touch screen or with the and butt...

Страница 14: ...er on Off The lamp has to be switched on using the local menu or DMX Lamp on by DMX on off On lamp can be switched on by DMX Off lamp cannot be switched on by DMX Lamp on delay 0 60min The lamp is aut...

Страница 15: ...buttons Auto screen on off On the screen is automatically rotated based on the angle of the BriteQ BTX TITAN Off the screenhe orientation is fixed MANUAL CONTROL LAMP Lamp control on off Set the lamp...

Страница 16: ...he special function 010 014 DMX input Wired DMX 015 019 DMX input Wireless DMX 020 024 Eco mode Lamp power 230W 025 029 Standard mode Lamp power 280W 030 049 Reserved 050 059 Pan Tilt speed mode 060 0...

Страница 17: ...to fast 244 249 Random colour selection by audio control Random colour selection by audio control 250 255 Auto random colour selection from fast to slow 8 8 000 255 COLOR FINE 9 9 6 000 255 EFFECT SPE...

Страница 18: ...n from fast to slow 11 11 8 ROTATING GOBO In the range of 000 059 DMX the gobo selection speed is Controlled by the effect speed channel Index set indexing on channel 12 9 000 Open Hole default 001 00...

Страница 19: ...ards gobo rotation from fast to slow 128 129 No rotation 130 255 Backwards gobo rotation from slow to fast 13 13 ROTATING GOBO ROTATION FINE 000 255 Fine indexing rotation 14 14 10 PRISM 000 019 Open...

Страница 20: ...channel 14 10 000 255 Prism indexing Prism rotation set position on channel 14 10 000 No rotation 001 127 Forwards prism rotation from fast to slow 128 129 No rotation 130 255 Backwards prism rotation...

Страница 21: ...5 Shutter open full lamp power 23 24 16 000 255 DIMMER Dimmer intensity from 0 to 100 24 25 000 255 DIMMER FINE Fine dimming DMX CHANNEL SHORT VERSION 24CH 25CH 16CH FUNCTION 1 1 1 PAN 2 2 PAN FINE Le...

Страница 22: ...ptimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit s opti...

Страница 23: ...ANNEX ANNEXE BIJLAGE ANHANG ANEXO BRITEQ 21 23 BTX TITAN DIMENSIONS COLOUR WHEEL...

Страница 24: ...ANNEX ANNEXE BIJLAGE ANHANG ANEXO BRITEQ 22 23 BTX TITAN FIXED GOBO WHEEL effective diameter 5 8mm ROTATING GOBO WHEEL...

Страница 25: ...ve the magnet E23 Tilt FB Err The vertical light coupling error Check that the light coupling line optical coupling switch and a plate of the relative position measurement E24 Tilt Zero Err Vertical m...