6. How To Set The Unit
6.1 Power On Display
Every time you turn on the unit, it will run built-in program to reset all motors to their home
position, the display will show as fig.4, you may hear some noises for about 20 seconds. It
will show warning sign if it goes wrong during resetting and you can press the MENU button
to view the error informations. After that the unit will be ready to receive DMX signal and the
display will show as fig.5.
Fig.4
Fig.5
Explanation of fig.5:
Base 40
°
C
Present temperature of base CPU is 40
°
C
001
Present start address
Md.1 22Ch.
Present channel mode is mode 1 (22 channels mode)
Lamp 30
°
C
Present temperature of lamp is 30
°
C
Warning signal blinking direct resetting error
6.2 Main Function
Turn on the unit, press
MENU
button into menu mode, press
UP
and
DOWN
button until the
required function is shown on the monitor. Select the function by
ENTER
button. Use
UP
and
DOWN
button to choose the submenu, press the
ENTER
button to store and
automatically return to the last menu. Press
MENU
button or let the unit idle one minute to
exit menu mode.
In the event of disconnecting with mains power, press
UP
button for one minute to enter
into menu mode. Press MENU button or let the unit idle one minute to exit.
The main functions are shown below
(
the grayed boxes are preset settings
)
:
BRITEQ®