5. Gobo and Lamp
5.1 Inserting/Exchanging rotating gobos
GOBO WHEEL 1 (replaceable)
GOBO WHEEL 2
DANGER!
Install the gobos with the device switched off only.
Unplug from mains before changing gobos!
CAUTION: Never unscrew the screws of the rotating gobo as the ball bearing will
otherwise be opened!
Please follow the steps below to insert/change rotating gobos
1. Open the cover by loosening the fastening screws on the cover.
2. Push the gobo plate (follow the direction 1) and gently pull out the plate (follow the
direction 2).
3. Take out the ring with an appropriate tool. Do not touch the surface of the glass gobo.
4. Remove the original gobo and inset a new one (glazy side towards the lamp). Insert the
ring to secure it in the gobo holder.
5. Install the gobo plate back into the gobo wheel. Make sure the gobo plate is installed
under the pressure plate.
BRITEQ®
8
BTX-300SW
5.2 Lamp
MSR/ MSD Gold 300/2 miniFastFit
Because of its high internal pressure, there might be a risk that the Discharge
lamp would explode during operation. The lamp emits intense UV radiation which
is harmful to the eyes and skin. The high luminance of the arc can cause severe
damage to the retina if you take a close look at the lamp.
To protect the lamp, always turn off the lamp first (via control panel or DMX
controller) and let the unit run at least five minutes to cool down before switching
off the mains supply. Never handle the lamp or luminaire when it is hot.
Do not touch the bulb with bare hands. If this happens, clean the lamp with
denatured alcohol and wipe it with a lint free cloth before installation.
The lamp generates UV radiation. Never operate the lamp without appropriate
shielding.
When lighting up, the lamp operates at high pressure and there is a slight risk of arc
tube rupture. The risk increases with age, temperature and improper handling of the
lamp. Do not use the lamp longer than its lifespan.
Make sure the lamp is located in the center of the reflector for the best projection.
Change Lamp
WARNING
1. Turn off the power.
2. Unscrew the two screws (A), open the lamp cover, turn it to
the position as the sketch shown below.
3. Hold the base of the lamp, anticlockwise turn until it is parallel
to the groove.
4. Inset a new lamp follow the groove, turn it clockwise to fix the
lamp.
5. Tighten the screws (A) to fix the lamp cover.
6. Turn the screws (B) to adjust the lamp position be sure
it is located in the center of the reflector for the best
projection.
In case of replacement of the lamp or maintenance, do not open the
fixture within 15 minutes until the unit cools down after switching off.