Installation

Height above hotplates

For best performance we suggest that the hood is installed at a distance between 65cm to75cm from
the hotplate surface. Under no circumstances should the hood be installed lower than 65cm above the
hotplate surface.

Ducting out/filtering

The hood can be used as a filtering version or as a ducted version. It is always preferable to install the
hood as a ducted version i.e. duct to an outside wall. If this is not practical, charcoal filters can be fitted.
In the filtering mode the air drawn in is purified as it passes through the charcoal filters, the air is then
recycled back into the kitchen. It is realistic to assume that using a hood in filtering mode will circulate
30% less air than by ducting out. Charcoal filters are an optional extra and will require replacing after
120 hours of use or at least every 6 months. Charcoal filters are not required if you duct out. If the
hood is used as a filtering version, please note that the filters will help reduce cooking odours but will
not reduce steam or condensation. If you wish to reduce steam, condensation and cooking odours then
you must duct out.

We strongly recommend that the hood is only used as a filtering version if it is impossible to duct out.

Ducting information

To obtain the best possible extraction performance use 150mm diameter ducting.Wherever possible
utilise rigid circular pipe or “Mega duct” ducting - both types are available via your Britannia dealer. Do
not use expanding concertina type ducting as this is not smooth on the interior and can cause air flow
restrictions. Do not use ducting that has a smaller diameter than 150mm as this will reduce extraction
rates and can increase noise levels. Please note ducting kits and ducting components are optional
accessories and have to be ordered - they are not supplied with the hood.

Maximum length of ducting run

4 metres with 1 x 90 degree bend

3 metres with 2 x 90 degree bends

2 metres with 3 x 90 degree bends

Note: the shorter the ducting run and the least number of bends give the best extraction performance.

Warning: Any ducting used must be fire retardant.

Unpacking the hood

On some models components are packed inside the polystyrene protection pieces.

Do not throw away the box and packaging until installation is fully completed.

3

90 degree bend

Code DUCT/690

Pipe connector

Code DUCT/693

One metre
ducting kit

Comprising: one
metre length pipe,
wall vent and 90
degree bend.

Code DUCT/2609

One metre
length pipe

Code DUCT/1100-6

Two metre
length pipe

Code DUCT/1200-6

One metre and two
metre length pipes can be
cut to the desired length

Wall vent with
gravity flaps

Code DUCT/6900

Combination of 6” (150mm) circular
pipe and flat channel (220mm x 90mm)
which is ideal for running on top of
wall units or between ceiling joists.

Megaduct kit 

Code DUCT/2652B

Horizontal bend

Code DUCT/950

Megaduct Ducting Kit

horizontal
bend

350

1000

1000

1000

Содержание K240 90CM

Страница 1: ...USER INSTRUCTIONS PRE PURCHASE INFORMATION INSTALLATION INSTRUCTIONS CHIMNEY HOOD MODELS K240 90CM and 100CM ...

Страница 2: ... When installed between adjoining wall cabinets the wall cabinets must not overhang the hob hotplate The following applies when ducting out If the room where the cooker hood is to be used contains a fossil fuel burning appliance such as a gas or oil central heating boiler then its flue must be of the room sealed or balanced flue type This hood is not suitable for use in a room where any open flue ...

Страница 3: ...erminations labelled SUPPLY are for the internal house wiring and the terminations labelled LOAD are for connection for the appliance WARNING THIS APPLIANCE MUST BE EARTHED Important The wires in this mains lead are coloured in accordance with the following code Green Yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead of this appliance may not correspond with the co...

Страница 4: ...ossible utilise rigid circular pipe or Mega duct ducting both types are available via your Britannia dealer Do not use expanding concertina type ducting as this is not smooth on the interior and can cause air flow restrictions Do not use ducting that has a smaller diameter than 150mm as this will reduce extraction rates and can increase noise levels Please note ducting kits and ducting components ...

Страница 5: ...and wall plugs provided See A fig 4 For added security two additional fixing screws and rawl plugs must be fitted see B fig 4 5 Ensure the electric supply is turned off Connect hood supply cable to the power supply 6 Connect the ducting to the outlet spigot of the hood 7 Fit bracket W fig 5 to the wall 8 See fig 6 Place the telescopic flue assembly carefully onto the hood and extend the upper sect...

Страница 6: ... to change the charcoal filters Changing the bulb First turn off the electricity supply to the hood Remove the retaining screw that holds the light diffuser in position Remove light diffuser Unscrew the light bulb and replace it only with Candle Halogen Lamp Ø35 E14 220 240Vac 28W or Incandescent Please note The information contained in this booklet is given in good faith and has been written for ...

Страница 7: ...6 1 2 3 4 6 5 7 8 9 10 A A B A B C D E W min 65cm 50mm ...

Страница 8: ...or domestic use only 4 Any service work will generally entail removal of the telescopic flue assembly to access key components including the motor If the flue assembly has been boxed in by means of a bridging shelf or any type of furniture this must be removed prior to our engineer s visit Before calling for service please check the following 1 Is there a power failure Turn on the appliance to che...

Отзывы: