Latour Canopy Hood Installation, Operating & Maintenance Instructions
W1100 Latour Built-In Canopy Extractor IO&M Nov 2010.docx
Page 5
9.
OPERATING INSTRUCTIONS
Switch on the power at the fused spur.
The extractor has 6 push-buttons which illuminate when selected.
Their functions are summarised in the table below.
After 30 hours accumulated running GREASE FILTER
SATURATION will be signalled by all 6 indicators flashing. Reset by
pressing Push-button FAN OFF (delay).
The extractor controller will automatically switch off the appliance if
there has been no operator action for 4 hours.
LIGHTS
ON/OFF
FAN ON
SPEED 1
FAN OFF
(Immediate)
FAN ON
SPEED 2
FAN ON
SPEED 3
FAN ON
SPEED 4
FAN OFF
Delayed for
10 Minutes
to clear
fumes
10.
MAINTENANCE
Regular maintenance is essential to ensure good performance and long-
life.
To clean the stainless steel surfaces of the extractor use a suitable
cleaning agent (Stainless Steel Cleaner and Polish). Glass surfaces
should be cleaned with a suitable glass cleaning agent.
Do not use abrasive cleaning materials or products.
Clean the grease filters in a dishwasher or by hand-washing in hot water
and detergent. Wash the filters at least every 2 months - sooner if the
extractor is used extensively.
To maintain the immaculate appearance of the extractor, and to minimise
fire risk, ensure that grease deposits on the extractor surfaces are kept to
a minimum by regular cleaning.
Removing the Grease Filters
The filters have an integrated sprung latch and release mechanism.
Release the latch by pulling the lever and remove the filter. The filter
is replaced by locating the fixed tabs on the filter into corresponding
slots in the extractor base and then pushing the filter into position with
the latch held open. Once the filter is in position carefully release the
lever, allowing the latch to engage.
Replacing Light Bulbs
The unit is fitted with 20W (20 Watt) 12V (12 Volt Low Voltage) G4
halogen capsule bulbs (lamps). Replacement lamps must be of the
same type (G4 12V 20W).
Never use lamps rated at over 20W.
Remove the frosted glass lens by carefully prising off the lens
retension ring (Figure 2), taking care to support the glass so that it
does not fall. (a fingernail, flat screwdriver, butter knife or similar
can be used to prise off the ring
–
take care not to scratch the
chrome bezel)
Grasp the lamp and carefully pull it sideways away from and out
of its connection block.
Insert replacement lamp.
Place the frosted lens with smooth face facing downwards (the
face you will see) into retension ring, offer the ring up and align
the ring clips with the corresponding innermost slots in the
chrome bezel and push the ring back into place - this is easiest if
one clip is inserted with the ring at a slight angle (so that you can
see it has located properly) and then pushing up to engage the
remaining two clips.
11. SPECIFICATIONS
Britannia Living
Eastern Rise
,
Trentham Lakes, StokeonTrent
,
ST4 8WG
Tel:
0844 463 9705
Email: [email protected]
-oOo-
CAUTION
To minimise the risk of fire, all instructions relating to
cleaning the grease filters and removing grease deposits
must be adhered to.
BTH-C-950,1150,1400 with INTERNAL BLOWER
Blower airflow, nominal:
1,000 m
3
/hr per fan
Noise level:
52dBA Single Fan
56dBA Twin Fan
Supply voltage:
220-240 volts~ 50Hz
Halogen lamp voltage:
12 volts
Blower power input:
250 watts Per Fan
Halogen lamp power:
BTH-C/CT-950:
BTH-C/CT-1150:
BTH-C/CT-1400:
2 x 20 watts
3 x 20 watts
4 x 20 watts
Total power:
Single Fan
Models:
BTH-C-950:
BTH-C-1150:
BTH-C-1400:
290 watts
310 watts
330 watts
Twin Fan
Models:
BTH-C-950:
BTH-C-1150:
BTH-C-1400:
540 watts
560 watts
580 watts
Electrical supply fuse rating:
Single Fan Models:
Twin Fan Models:
3 amp
5 amp
Blower spigot diameter:
150mm