Latour Canopy Hood Installation, Operating & Maintenance Instructions
W1100 Latour Built-In Canopy Extractor IO&M Nov 2010.docx
Page 3
6.
ADDITIONAL DUCTING INFORMATION
This hood is designed for ducting out, i.e. duct to an outside wall. To
obtain the best possible extraction performance use 150mm
diameter ducting. Wherever possible utilise rigid circular pipe or
“
Mega duct
”
ducting - both types are available via your Britannia
dealer. Do not use flexible expanding concertina type ducting
unless it is absolutely necessary and then only for short runs (of
less than 1 metre) or initial connection as this is not smooth on the
interior and will cause air flow restrictions.
Do not use ducting that has a smaller diameter than 150mm as this
will reduce extraction rates and can increase noise levels. Please
note ducting kits and ducting components are optional accessories
and have to be ordered - they are not supplied with the hood.
Recommended maximum length of ducting run.
4 metres with 1 x 90 degree bend
3 metres with 2 x 90 degree bends
2 metres with 3 x 90 degree bends
Note: The shorter the ducting run and the least number of bends
gives the best extraction performance.
Warning:Any ducting used must be fire retardant.
7.
PRODUCT GUARANTEE
Britannia service & spare department
Tel:
+44 (
0
)
8
44 463 9705 (option 1)
E
mail: [email protected]
GUARANTEE
What the Guarantee covers
Our service division will repair or replace free of charge
any defect or component that is due to faulty material or
workmanship, provided that such a defect occurs within
2 years of date of purchase and that:
1. Our service division is notified promptly of any defects.
Under the terms of the guarantee the appliance must be
made available for service during normal working hours,
Monday to Friday.
2.
The appliance is installed in accordance with these
instructions and for normal domestic use.
3.
The guarantee does not apply if the appliance is
repaired or modified by any other person than a member
of our service division. The guarantee does not cover
misuse, improper installation or any installation in
commercial premises. This product is for domestic use
only.
4.
Any service work will generally entail removal of the
telescopic flue assembly to access key components
including the motor. If the flue assembly has been boxed
in by means of a bridging shelf or any type of furniture
this must be removed prior to our engineer
’
s visit.
Before calling for service, please check the following:
1. Is there a power failure? Turn on the appliance to check
the mains supply.
2.
Check that the fuse has not blown.
3.
Please note that bulbs are not covered under the
guarantee.
In the event of service being required, our service
division will request the following information:
1. Your name, address and postcode.
2.
Your telephone numbers for home and work.
3.
The model number and colour of the appliance.
4.
Precise details of the fault.
5.
Date of purchase.
Please note that when the service engineer visits he will
require seeing your proof of purchase date so please retain
your receipt.
1m
1m
35cm
One metre length pipe
Code DUCT/1100-6
Two metre length pipe
Code DUCT/1200-6
Note: One metre and two metre length pipes can be cut to
the desired length.
Wall vent with
gravity flaps
Code DUCT/6900
One metre ducting kit
Comprising: one metre
length pipe, wall vent and
90 degree bend.
Code DUCT/2609
90 degree bend
Code DUCT/690
Pipe connector
Code DUCT/693
Megaduct Ducting Kit
Combination of 6
”
(150mm)
circular pipe and flat channel
(220mm x 90mm) which is
ideal for running on top of
wall units or between ceiling
joists.
Code DUCT/2652B
Horizontal bend
Code DUCT/950