6. 

ADDITIONAL DUCTING INFORMATION  

This hood is designed for ducting out, i.e. duct to an outside wall. To 
obtain the best possible extraction performance use 150mm 
diameter ducting. Wherever possible utilise rigid circular pipe or 

Mega duct

 ducting - both types are available via your Britannia 

dealer. Do not use flexible expanding concertina type ducting 
unless it is absolutely necessary and then only for short runs (of 
less than 1 metre) or initial connection as this is not smooth on the 
interior and will cause air flow restrictions.  

Do not use ducting that has a smaller diameter than 150mm as this 
will reduce extraction rates and can increase noise levels. Please 
note ducting kits and ducting components are optional accessories 
and have to be ordered - they are not supplied with the hood. 

Recommended maximum length of ducting run. 

4 metres with 1 x 90 degree bend 

3 metres with 2 x 90 degree bends 

2 metres with 3 x 90 degree bends 

Note: The shorter the ducting run and the least number of bends 
gives the best extraction performance. 

 

 

Warning:Any ducting used must be fire retardant. 

7. 

PRODUCT GUARANTEE 

 

                  Britannia service & spare department

 

        

Tel: 

+44 (

0

)

8

44 463 9705 (option 1)

 

      

E

mail: [email protected]

 

 

GUARANTEE 

 

What the Guarantee covers 

Our service division will repair or replace free of charge 
any defect or component that is due to faulty material or 
workmanship, provided that such a defect occurs within 
2 years of date of purchase and that: 

1.  Our  service  division  is  notified  promptly  of  any  defects. 

Under the terms of the guarantee the appliance must be 
made available for service during normal working hours, 
Monday to Friday. 

2.

 

The  appliance  is  installed  in  accordance  with  these 
instructions and for normal domestic use. 

3.

 

The  guarantee  does  not  apply  if  the  appliance  is 
repaired or modified by any other person than a member 
of  our  service  division.  The  guarantee  does  not  cover 
misuse,  improper  installation  or  any  installation  in 
commercial  premises.  This  product  is  for  domestic  use 
only. 

4.

 

Any  service  work  will  generally  entail  removal  of  the 
telescopic  flue  assembly  to  access  key  components 
including the motor. If the flue assembly has been boxed 
in  by  means  of  a  bridging  shelf  or  any  type  of  furniture 
this must be removed prior to our engineer

s visit. 

 Before calling for service, please check the following: 

1.  Is there a power failure? Turn on the appliance to check 

the mains supply. 

2.

 

Check that the fuse has not blown. 

3.

 

Please  note  that  bulbs  are  not  covered  under  the 
guarantee. 

In  the  event  of  service  being  required,  our  service 
division will request the following information: 

1.  Your name, address and postcode. 

2.

 

Your telephone numbers for home and work. 

3.

 

The model number and colour of the appliance. 

4.

 

Precise details of the fault. 

5.

 

Date of purchase. 

  

Please  note  that  when  the  service  engineer  visits  he  will 
require seeing your proof of purchase date so please retain 
your receipt.
 

 

 

 

1m 

1m 

35cm 

One metre length pipe 
Code DUCT/1100-6 

Two metre length pipe 
Code DUCT/1200-6 

Note: One metre and two metre length pipes can be cut to 
the desired length. 

Wall vent with 
gravity flaps 
Code DUCT/6900 

One metre ducting kit 
Comprising: one metre 
length pipe, wall vent and 
90 degree bend. 
Code DUCT/2609 

90 degree bend 
Code DUCT/690 

Pipe connector 
Code DUCT/693 

Megaduct Ducting Kit 
Combination of 6

 (150mm) 

circular pipe and flat channel 
(220mm x 90mm) which is 
ideal for running on top of 
wall units or between ceiling 
joists. 
Code DUCT/2652B
 

Horizontal bend 
Code DUCT/950 

Содержание BTH-C-950

Страница 1: ...pply before carrying out any cleaning or maintenance operations Pay particular attention to fire risk when frying To minimise the risk of fire all instructions relating to cleaning the grease filters and removing grease deposits must be adhered to Do not flambé under the extractor See Section 7 for PRODUCT GUARANTEE information 4 INSTALLATION Do not throw away the box and any internal packaging un...

Страница 2: ...er is switched off and that the ducting is securely fastened to the spigot Check if applicable that any external fans are plugged into the unit Push the extractor up through the prepared opening until the spring toggles are heard to snap over the edge of the opening we recommend that two people do this supporting one end of the extractor each Carefully release the unit ensuring that it is supporte...

Страница 3: ...ailable for service during normal working hours Monday to Friday 2 The appliance is installed in accordance with these instructions and for normal domestic use 3 The guarantee does not apply if the appliance is repaired or modified by any other person than a member of our service division The guarantee does not cover misuse improper installation or any installation in commercial premises This prod...

Страница 4: ...ing Maintenance Instructions W1100 Latour Built In Canopy Extractor IO M Nov 2010 docx Page 4 8 LATOUR CANOPY GENERAL ARRANGEMENT DRAWINGS Single Fan Models BTH C 950 BTH C 1150 BTH C 1400 Twin Fan Models BTH CT 950 BTH CT 1150 BTH CT 1400 ...

Страница 5: ...n position carefully release the lever allowing the latch to engage Replacing Light Bulbs The unit is fitted with 20W 20 Watt 12V 12 Volt Low Voltage G4 halogen capsule bulbs lamps Replacement lamps must be of the same type G4 12V 20W Never use lamps rated at over 20W Remove the frosted glass lens by carefully prising off the lens retension ring Figure 2 taking care to support the glass so that it...

Отзывы: