background image

8

Need help?

 Give us a call on

 0330 026 6273

 and speak to one of our trained advisors.  

Installation - Mixer Unit

Hot

Cold

Out

Mounting

Insert the filters & 

Insert the filters & 

connect the water 

connect the water 

supplies.

supplies.

Connect 

Connect 

outlet 

outlet 

feed. 

feed. 

Plug power 

Plug power 

supply cable into 

supply cable into 

power socket & 

power socket & 

mixer unit. Plug 

mixer unit. Plug 

in the interface 

in the interface 

unit cable.

unit cable.

Find a suitable place for the mixer 

Find a suitable place for the mixer 

unit. It must be no further than 1.2m 

unit. It must be no further than 1.2m 

away from a socket & no 

away from a socket & no 

further than 3m from where the 

further than 3m from where the 

interface unit will be installed.

interface unit will be installed.

Mark hole & drill, fix the mixer unit to 

Mark hole & drill, fix the mixer unit to 

surface using suitable screws 

surface using suitable screws 

(not supplied).

(not supplied).

Slide spade  

Slide spade  

connectors onto 

connectors onto 

each solenoid.

each solenoid.

The connectors 

The connectors 

come in the  

come in the  

following pairings:

following pairings:

Grey & Blue

Grey & Blue

Purple & Brown

Purple & Brown

4

3

2

1

5

6

REMEMBER

To flush the 

pipe work 

before 

connecting 

Connect the 

Connect the 

outlet feed to 

outlet feed to 

a T-piece (not 

a T-piece (not 

supplied) & run 

supplied) & run 

the pipe work to 

the pipe work to 

elbows.

elbows.

Connect solenoid 

Connect solenoid 

valves.

valves.

REMEMBER

To chase the 

cables down 

the wall to 

interface  unit.  

REMEMBER

Mixer unit mus

be installed 

flat on floor or 

on a wall with 

outlets facing 

down 

IMPOR

TANT

Rear ac

cess  

will be r

equired 

for futur

e  

servic

e and 

maint

enanc

e.

IMPOR

TANT

Fit isola

tion 

valves f

or  

future servic

and  

maint

enanc

e.

IMPOR

TANT

Make sur

e to  

fit the spade 

 

connect

ors 

in the c

orrect 

pairings.

Содержание WavePlus Dual Outlet Touchpad

Страница 1: ...ions and User Guide WavePlus Dual Outlet Touchpad Models Covered All WavePlus Showers Please keep this booklet for future reference Installer when you have read these instructions please ensure you leave them with the user ...

Страница 2: ... for your guidance to a safe and successful installation so please read them thoroughly and retain for future reference We recommend the installation is carried out by a suitably qualified person and must conform with current I E E Wiring Regulations BS7671 and Building Regulations Part P and Part G Contents Important Safety Information 3 Specifications 4 Water Requirements 5 Water Connections 6 E...

Страница 3: ...tions 1999 and Scottish Byelaws 2004 Before starting any installation please consider the following Before drilling into walls check that there are no hidden electrical wires cables or water supply pipes This can be checked with the aid of an electronic detector Do not install this shower unit in a room environment without adequate ventilation or an extractor fitted This is required to prevent con...

Страница 4: ...eaded 1 2 BSP Male Threaded Min 0 1 MPa 1 bar Max 0 6 MPa 6 0 bar Working Pressures Inlet Connection Cold Water Supply Tools You ll Need Pack Contents Cross head Screwdriver Pencil Drill Pipe Cutter Pliers Pipe Wire Detector Spirit Level Pressure BAR 0 Specifications Hot Water Supply Light Commercial Recommended Usage Healthcare Domestic Measurements 1 2mm Hex Key Silicone Gun Safety Glasses Adjus...

Страница 5: ... 1bar at a minimum flow rate of 10 litres per minute is recommended for full performance The maximum static inlet pressure must not exceed 1 0MPa 10bar The shower must be connected to a mains water supply only with a minimum working inlet pressure of 0 1 MPa 1bar at a minimum flow rate of 10 litres per minute The maximum static inlet pressure must not exceed 1 0MPa 10bar If it is intended to opera...

Страница 6: ...een flushed through turn off the water supplies at the stop service valves The supplied filter washers supplied must be fitted into both inlets The connecting pipe work must present 1 2 BSP connectors to the male thread on the inlet connections Important The pipe work must run as straight as possible to the Mixing Valve minimising 90º angled bends as this could affect the inlet pressure to the Mix...

Страница 7: ...they are installed used correctly and receive regular maintenance in accordance with these instructions This product must not be modified in any way as this will invalidate the guarantee Ensure an electric socket is near the place of installation and can be reached by the power cord If a socket needs to be installed please seek the services of a qualified electrician Warning Only the power adaptor...

Страница 8: ... unit to Mark hole drill fix the mixer unit to surface using suitable screws surface using suitable screws not supplied not supplied Slide spade Slide spade connectors onto connectors onto each solenoid each solenoid The connectors The connectors come in the come in the following pairings following pairings Grey Blue Grey Blue Purple Brown Purple Brown 4 3 2 1 5 6 REMEMBER To flush the pipe work b...

Страница 9: ...licone around silicone around the Interface unit the Interface unit 2 1 Install suitable batons Install suitable batons if required into the if required into the cavity Punch out section in cavity Punch out section in top left for the cable top left for the cable Thread interface cable Thread interface cable through hole plug into through hole plug into Interface unit Interface unit Interface unit...

Страница 10: ...sly increase the flow rate press and hold 3 Decrease Flow Rate To decrease the flow rate by 1lpm press once to continuously decrease the flow rate press and hold 4 Increase Temperature To increase the temperature by 1 C press the red droplet once to continuously increase the temperature press and hold 5 Decrease Temperature To decrease the temperature by 1 C press the blue droplet once for a cold ...

Страница 11: ...ster temperature Press the button again for the shower to start 2 Factory Reset Press and hold to return memory functions to factory settings 3 User Presets Select which user preset you wish to use then press the button to start the shower with this preset 4 System Setup Press and hold to connect outlets to control panel 5 Cleaning Press and hold for cleaning process 6 Thermal Disinfection Press a...

Страница 12: ...ld the Start button until Press hold the Start button until the control keys light up to save the control keys light up to save settings settings Press hold the Start button until Press hold the Start button until the control keys light up to save the control keys light up to save settings settings During the process the During the process the Start button will flash Start button will flash as dif...

Страница 13: ...he top button to factory reset factory reset The control keys will light up to The control keys will light up to confirm that the control panel has confirm that the control panel has been factory reset been factory reset 1 2 3 The light around the Start Main The light around the Start Main User button will disappear to User button will disappear to confirm the Touchpad is locked confirm the Touchp...

Страница 14: ...thermal disinfection function disinfection function A 9 second A 9 second countdown will countdown will appear before the appear before the process starts process starts During the process the Start button During the process the Start button will flash whilst the hot button will flash whilst the hot button is illuminated is illuminated Once finished the Start button Once finished the Start button ...

Страница 15: ...rect temperature If correct check if the problem occurs on another outlet If the other outlet works check that there are no devices e g flow regulators impeding flow to the problem outlet AL9 displayed Thermal Disinfection interruption Check pipe work for any blockages and that water is reaching the inlets Clean filters and replace if necessary If problem persists please contact Customer Services ...

Страница 16: ...er your product Alternatively visit www bristan com register For any other queries please call our Customer Service on 0330 026 6273 where our expert team of advisors will be able to offer you any help and advice For full guarantee terms and conditions visit www bristan com guarantees Guarantee Bristan Group Ltd Birch Coppice Business Park Dordon Tamworth Staffordshire B78 1SG Web www bristan com ...

Отзывы: