background image

3

Pressure

BAR

1.0

5.0

4.0

2.0

3.0

0.

Pressure

BAR

1.0

5.0

4.0

2.0

3.0

0.

Need help? 

Give us a call on 

0330 026 6273 

and speak to one of our trained advisors.  

IMPORTANT: 

Please ensure both supply 

pipes are flushed before connecting the 

mixing valve to prevent plumbing/pipe 

debris from entering the mixing valve.

1.  Choose the configuration of the 

elbows as per the diagram below. 

Choose whether to have a top or 

bottom outlet by using the blanking 

cap and o-ring. 

2.  Plumb the pipes to the desired 

location for the mixing valve. 

3.  Remove the backplate and mark the 

position of the fixing holes.

4.  Drill and use the screws and plugs 

provided to secure the backplate to  

the wall.  

5.  Connect the valve to the pipework, 

using filters to prevent debris 

entering the valve (not supplied).  

We recommend using a high 

tightening torque (45-50Nm) on all 

22mm compression fittings to  

secure the valve. 

 

Remember: 

Ensure the valve is fitted 

with the hot inlet on the left, cold 

on the right when viewed from the 

front. 

6.  Locate the valve body on to the 

backplate and secure with the  

grub screw.

Maximum Static Pressure:  

1.0 MPa (10.0 bar)

Maximum Pressure 

Differential:  

10:1

Min:

 0.01 MPa  

(0.1 bar)

Max:

 0.5 MPa 

(5.0 bar)

Working Pressures

Inlet & Outlet  

Connection

22mm

Specifications

Inlet Water Temperature

5°C

20°C

Cold Water Supply

Min:

 5°C 

Max:

 20°C

65°C Recommended

Hot Water Supply

80°C

IMPORTANT

The inlet hot water must  

be at least 10°C above the  

required blend temperature.

TMV Designation

65°C

HP-T44 & LP-T44

Outlet  

Temper

ature 

Pre-set t

o  

43

°

C

Specifications

Installation

Содержание TS4753ECP

Страница 1: ...nstructions and User Guide Thermostatic Mixing Valve Models Covered TS4753ECP Please keep this booklet for future reference Installer when you have read these instructions please ensure you leave them...

Страница 2: ...to clog up the mechanical areas of the valve This product must not be modified in any way as this will invalidate the guarantee Full access must be made available for future maintenance servicing pur...

Страница 3: ...5 Connect the valve to the pipework using filters to prevent debris entering the valve not supplied We recommend using a high tightening torque 45 50Nm on all 22mm compression fittings to secure the...

Страница 4: ...ing 1 9 O Ring 1 10 O Ring 1 11 O Ring 1 12 O Ring 1 13 O Ring 1 14 O Ring 1 15 O Ring 1 16 Grub Screw 1 17 Bottom Cap 1 18 Adjusting Screw 1 19 Screw 2 20 Head 1 21 Spindle Nut 1 22 Adjustment Housin...

Страница 5: ...ot rinsed off straight after use Household bleaches and cleaners contain harsh chemicals and may damage the surface finish Avoid using abrasive cloths scouring pads scrub sponges steel wool or anythin...

Страница 6: ...erature anti clockwise for a hotter temperature 4 Wait for a few minutes after adjusting for the temperature to stabilise Use a thermometer to measure the outlet temperature Repeat steps X and X until...

Страница 7: ...Remove the bottom cap and piston assembly together with the thermostat and return spring Note The piston can be dis assembled further but this is not necessary for cleaning servicing 5 Remove O rings...

Страница 8: ...all our products effective from the date of purchase to give you peace of mind To start your free guarantee simply scan the QR code and register your product Alternatively visit www bristan com regis...