IMPORTANT - PLEASE READ

These fittings need to be installed in accordance with the following Installation Requirements and Notes 

(IRN) to ensure they meet the requirements of the Water Supply (Water Fittings) Regulations 1999 and the 

Scottish Byelaws 2004.

IRN R001

See text of entry for Installation Requirements or Notes.

IRN R006

This tap or combination tap assembly has a Type AUK3 air gap and is therefore for installation in any 

premises to protect against a backflow risk up to a Fluid Category 5.

Cleaning & Maintenance

Your fitting has a high quality finish and should be treated with care to preserve the visible surfaces.
All finishes will wear if not cleaned correctly. The only safe way to clean your product is to wipe with a soft damp
cloth. Stains can be removed using washing up liquid. All bathroom cleaning product (powders and liquids) will 

damage the surface of your fitting, even the non-scratch cleaners.

NOTE:- Never use abrasive detergents or disinfectants or those containing alcohol, hydrochloric or phosphoric 
acid.

If the fitting begins to drip:
1. Turn off both water supplies.
2. Remove the handles (d) by pulling from valve (a) and spline adaptor (b). Then remove screw (c), 

by unscrewing from valve (a)

3. Also remove spline adaptor (b) to avoid damaging it.
4. Using a suitable spanner, remove valve (a). Once removed, carefully clean seating, rubber washer and ceramic 

disc.

5. Replace all of the above and turn on the water supply.
6. If the problem persists please contact out customer services helpline on 0844 701 6273.