We advise that your fitting is regularly
serviced in hard water areas to maintain
optimum performance (see map of Hard
Water Regions in the UK on page 17.
If your fitting begins to leak the following
should be carried out;
Isolate both hot and cold water supplies to
the tap by either:
•
Turning the water supply off at the mains
stopcock or
•
Turning off the isolation valves to the tap.
1. Remove the cap at the rear of the handle
to reveal the concealed grub screw.
2. Unscrew the grub screw and pull the
handle upwards from the valve spindle.
3. Unscrew the shroud , remove the
cartridge retaining nut and pull out the
cartridge.
4. Carefully clean the cartridge seals and
seating.
5. If necessary replace the cartridge.
Please visit www.bristan.com/sparesfinder in
order to find spare parts for this product.
6. Replace the cartridge into the tap body
and tighten retaining nut fully.
7. Replace all remaining components and
turn on water supply.
8. Check for leaks and contact our helpline if
problem persists.
Handle Lever
Valve
Tap Body
Handle
Maintenance cont.
Cleaning the Cartridge – Single Lever Basin Mixer
16
Retaining Nut
Shroud
Plinth
Cap
Grub Screw