background image

 
 
 
 
 
 

 

 

 

 

Centipede 2

®

   

Module Temperature Control System 

With 

7.0” Touchscreen Display (C2MOD-OI-7)

        

Instruction Manual 

       

  

 

 

Read and understand this manual before operating or servicing this 
temperature control system.  Failure to understand how to safely 
operate these controllers could result in an accident causing serious 
injury or death.  Only qualified personnel should operate or service 
these controllers.   

 

Содержание C2MOD-OI-7

Страница 1: ...on Manual Read and understand this manual before operating or servicing this temperature control system Failure to understand how to safely operate these controllers could result in an accident causin...

Страница 2: ...Starting Up 10 Zone Discovery 10 Understanding the Operator Interface Status LED 11 Main Menu 11 View System 12 Multi Zone View Navigation 12 Single Zone View 13 Understanding the Status Codes 14 Edit...

Страница 3: ...All electrical wiring must follow local electrical codes and NEC Article 427 Final installation wiring is to be inspected by the authority that has jurisdiction in the area where the heater and tempe...

Страница 4: ...or globally across system Temperature set point high limit alarm temperature and low limit alarm temperature Operator interface displays actual temperature power duty cycle of heater and time date st...

Страница 5: ...perator interface using any of the available input strings 1 4 5 Connect plug in the power to the heaters Turn on operator interface 6 In the Global Program menu select Global Prog Select String Selec...

Страница 6: ...om the heating jacket to the C2MOD C unit This connector provides the control power and RTD temperature sensor input 2 Plug in the CAT 5 connectors on each side of the module These connections are bi...

Страница 7: ...4 Connect up to four separate strings of Centipede 2 modules PN C2MOD C utilizing CAT5 communication cables Connect up to 64 modules per string 128 total modules D RS 232 External Communication Port S...

Страница 8: ...ved Touchscreen Interface Mounting Instructions C2MOD OI 7 comes equipped with four 4 40 mounting screws and nuts for easy installation Cut out a panel using the illustrations below Use 4 40 screws wa...

Страница 9: ...tus of your heater system with its LED light found on the front Green Temperature is within the high and low limits and no alarm conditions exist Blinking Red An alarm condition exists See Operator In...

Страница 10: ...e Centipede 2 Operator Interface Unit turn on the main power switch The firmware version will initially be shown on the screen Zone Discovery Every time the operator interface unit is powered on a zon...

Страница 11: ...ntipede 2 Module Network Green All the modules in the network are within their temperature limits and no errors exist Blinking Red One or more of the modules in the network have errors Solid Red No mo...

Страница 12: ...color Error status mode Status message provided in Single Zone view Touch any zone in the Multi Zone View to go to the Single Zone View B Changes Multi Zone view by String number ALL 1 2 3 or 4 C Home...

Страница 13: ...tus mode Orange Color Alarm Latch Mode B Displays zone parameters Set point low limit alarm high limit alarm alarm latch on off zone on off C Locate To locate module press to turn ON The viewed module...

Страница 14: ...us Message Description OK No alarms present Hi Temp Current actual temperature is above high alarm limit Lo Temp Current temperature is below the low alarm limit Short RTD RTD is shorted Open RTD RTD...

Страница 15: ...ingle Zone view Parameter Definitions Set Point Target temperature Range 0 to 325 C Low Alarm Low temperature limit Module will go into alarm condition if sensor detects temperature below this setting...

Страница 16: ...MING Select one of the three choices A Global program ALL MODULES in a system B Global program BY OUTPUT STRING 1 4 C Reset to Default Settings NOTE To determine which string you want to program trace...

Страница 17: ...arget temperature Range 0 to 325 C Low Alarm Low temperature limit Module will go into alarm condition if sensor detects temperature below this setting High Alarm High temperature limit Module will go...

Страница 18: ...hts reserved Programming Low Alarm Set Point and High Alarm 1 Touch the desired field A numeric keyboard screen appears 2 Input the desired temperature 0 to 325 C Touch when complete exits back to Glo...

Страница 19: ...rights reserved 19 Reset Default Settings Getting There Main Menu Global Program Reset Default Setting to confirm to cancel action and return to Global Programming menu NOTE Resetting to the default s...

Страница 20: ...reserved OPTIONS SETUP A General General Options Set O I name scroll rate and date time See page 21 B Network Modbus settings See page 24 C Password Management See page 25 D Detect Zones See page 26...

Страница 21: ...21 General Options Getting There Main Menu Options Set up General Options Basic Navigation Touch the desired field to program See pages 22 to 23 for detailed instructions Saves General Option changes...

Страница 22: ...lete exits back to General Options screen 3 Touch in General Options menu to save changes Change Scroll Rate NOTE The default Scroll Rate is set to 5 seconds 1 Touch the Scroll Rate field A numeric ke...

Страница 23: ...buttons to change date and time Touch the Exit icon when complete 3 Touch in General Options menu to save changes Change Clock View 1 Toggle between 24 HR and 12 HR clock by pressing button next to Ti...

Страница 24: ...etting There Main Menu Options Set up Network Parameter Definitions Address Modbus address of the C2MOD OI Range 0 to 255 Enable Toggles between Modbus RTU and LUI Local User Interface protocol o ON M...

Страница 25: ...bled to edit settings Getting There Main Menu Options Set up Password MGT Basic Navigation Touch the desired field to program See below for detailed instructions Saves Password Management changes Exit...

Страница 26: ...Password Mode is Disabled or someone is logged in The mode is Disabled when Password Mode is Enabled and someone is logged out Enter Password Place to enter password when password mode is enabled Use...

Страница 27: ...n Menu Options Set up Alarm Setup Alarm Latch Set up Touch the Latch parameter to toggle ON OFF See page 14 for definitions o Hi Temperature Latch o Lo Temperature Latch o Open RTD Latch o Short RTD L...

Страница 28: ...h errors are displayed on the operator interface The only parameter that can be toggled OFF is the Lo Temp Alarm Log Reset Touch Alarm Log Reset icon to show ON status Press to reset alarm log Alarm E...

Страница 29: ...AMP 240VAC max Do not replace fuse with live power applied to Centipede 2 Only authorized personnel should replace fuse 1 Remove power from unit 2 Replace the blown fuse with a new one of the specifie...

Страница 30: ...s required to utilize the RS 232C communications mode The Centipede 2 requires a straight through communication cable to use the Male DB9 connector to mate to the Female DB9 installed in the C2MOD OI...

Страница 31: ...3 Repeat process for remaining wires Alarm Latch Feature This feature is user configurable The Factory default is ON If set to ON an alarm condition will require the user to reset the alarm to return...

Страница 32: ...operator interface unit verify that power is being supplied to unit Make sure communication cable is secure For Module unit verify that the communication cable is properly connected LED is blinking re...

Страница 33: ...Centipede 2 Module System Instructions BriskHeat Corporation All rights reserved 33...

Страница 34: ...Centipede 2 Module System Instructions 34 BriskHeat Corporation All rights reserved...

Страница 35: ...Centipede 2 Module System Instructions BriskHeat Corporation All rights reserved 35...

Страница 36: ...clude labor costs for installation or removal of the equipment or parts covered by this warranty and BriskHeat shall not be responsible for such labor costs Limitation This warranty shall not apply to...

Отзывы: