background image

17

REPLACING LIGHT BULBS

CAUTION: Light bulb becomes extremely hot when turned on.

DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns.

Make sure all power is turned off and bulbs are not hot.

Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 degrees, 
stops and falls out.

If bulbs are diffi cult to turn due to prolonged use, fi rmly attach a glass suction cup approximately the diameter of 
the bulb or use a rubber/latex glove and turn counter clockwise.

Replacement bulbs are available at specialty lighting stores.  Purchase type GU-10 50W halogen.

For part numbers please turn to page 21 of the manual.

Maintenance – 

Lights

Содержание BFG-E30AG

Страница 1: ...Use Care and Installation Guide Model number Serial Number AUG12 0601 BFG E30AG BFG E36AG BMI E30BG BMI E36BG BMI E36BS BVE E30AS BVE E36AS ...

Страница 2: ......

Страница 3: ...Options 7 Hood Specifications 8 10 Mounting the Hood BFG 11 Mounting the Hood BMI 12 Mounting the Hood BVE 13 Ductless Recirculating 14 FEATURES CONTROLS Mechanical Controls 15 MAINTENANCE Hood and Filter Cleaning 16 Lights 17 TROUBLESHOOTING 18 WIRING DIAGRAMS 19 20 LIST OF PARTS AND ACCESSORIES 21 Table of Contents ...

Страница 4: ... EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT b NEVER PICK UP A FLAMING PAN You may be burned c DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result d Use an ex...

Страница 5: ...rical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If codes permit and a separate ground wire is used it is recommended that a qualified electrician determine that the ground path is adequate Do not ground to a gas p...

Страница 6: ...irculating kit accessory HARDWARE PACKAGE CONTENTS 1 Suction Cup PARTS SUPPLIED MODELS BFG ExxAG BMI ExxBx BVE ExxAS 1 Hood with internal blower 1 Duct cover wall bracket 1 Duct cover assembly top and bottom 1 6 round backdraft damper pre installed 2 50W GU 10 halogen light bulbs pre installed 1 Stainless steel mesh filter BFG BMI 2 BVE 1 Canopy glass BFG models only 1 Canopy glass or stainless st...

Страница 7: ...lent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round roof cap 30 Ft x Ft 7 or 8 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length of a 3 1 4 x 10 rectangul...

Страница 8: ...while hoods mounted too high will be hard to reach and will loose its performance and efficiency If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any differences Chart A BFG BMI BVE A 22 23 27 1 2 B 26 27 32 C 42 42 42 1 2 Duct cover extension kit available for ceiling heights up to 12 f...

Страница 9: ...ing option Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting Options Installation Ducting Options side wall cap w gravity damper Soffit or crawl space Roof Pitch w Flashing Cap ductless recirculating side wall cap w gravity damper blower housing blower housing blower housing blower housing ...

Страница 10: ...8 Installation BFG Hood Specifi cations 16 9 16 8 15 16 6 7 8 15 1 8 19 3 4 10 5 8 19 11 16 10 3 8 30 or 35 7 16 Min Ducted 22 Min Recirc 26 Maximum 42 FRONT SIDE TOP BACK 3 7 8 3 15 16 6 20 ...

Страница 11: ...9 Installation BMI Hood Specifi cation 17 1 4 8 15 16 15 7 8 6 7 8 19 3 4 10 5 8 23 15 16 10 3 8 30 or 35 3 16 Min Ducted 23 Min Recirc 27 Maximum 42 FRONT SIDE TOP BACK 2 5 16 3 15 16 3 15 16 6 ...

Страница 12: ... 7 16 13 16 3 15 16 8 3 4 29 15 16 or 35 7 8 1 9 16 6 7 8 19 3 4 12 13 5 16 12 5 16 Min Ducted 27 1 2 Min Recirc 32 Maximum 42 1 2 4 1 3 FRONT SIDE TOP BACK 2 3 1 2 C L Installation BVE Hood Specifi cation ...

Страница 13: ... ceiling or soffit using 2 6 x 1 screws FIG A 3 9 Install duct work and seal with aluminum duct tape Re install junction box with cable lock and install the electrical FIG B 2 10 Power up hood to verify all functions and check for leaks around duct tape 11 Place telescopic duct covers onto hood and extend inner top duct cover upwards and secure to duct cover bracket using 2 M3 5 x 8 screws 12 Rein...

Страница 14: ...rews FIG A 3 9 Install duct work and seal with aluminum duct tape Re install junction box with cable lock and install the electrical FIG B 2 10 Power up hood to verify all functions and check for leaks around duct tape 11 Place telescopic duct covers onto hood and extend inner top duct cover upwards and secure to duct cover bracket using 2 M3 5 x 8 screws 12 Reinstall stainless steel mesh filter I...

Страница 15: ...e the hood 8 Center and attach duct cover bracket to wall below ceiling or soffit using 2 M6 x1 screws 8 Install electrical and duct work Seal duct work with aluminum duct tape 9 Power up hood and check for leaks around duct tape 10 Place telescopic duct covers onto hood and extend inner top duct cover upwards and secure to duct cover bracket using 2 M3 5 x 8 screws if using hood in recirculating ...

Страница 16: ...ation RECIRCULATING KIT REQUIRED IF NO DUCTING IS USED Kit includes charcoal filters charcoal filter brackets and air diverter plate Hood Model Part No Filters in Pkg BFG models BRC 0003 2 BMI models BRC 0005 2 BVE models BRC 0001 2 1 Purchase recirculating kit per the part number above 2 Secure air diverter plate to wall below duct cover bracket FIG B Run 6 ducting from top of hood and secure to ...

Страница 17: ... Blower Speed Selection Blower Off The blower will be powered off by pressing Blower Speed Selection Select one of three speed levels by pressing Lights On Off Power lights on and off by pressing 3 Features Controls Mechanical Controls ...

Страница 18: ...h and with the grain Do not use any product containing chlorine bleach Do not use orange cleaners Stainless Steel Mesh Filters The mesh filter s installed by the factory are intended to filter out residue and grease from cooking They need not be replaced on a regular basis but are required to be kept clean Remove and clean by hand or in dishwasher on low heat Spray degreasing detergent and leave t...

Страница 19: ...urning bulb counter clockwise Note Bulb does not unscrew it turns 60 degrees stops and falls out If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approximately the diameter of the bulb or use a rubber latex glove and turn counter clockwise Replacement bulbs are available at specialty lighting stores Purchase type GU 10 50W halogen For part numbers please turn t...

Страница 20: ...otor is not secure in place 1 Tighten the motor in place 2 Damaged blower wheel 2 Replace the blower 3 The hood is not secured in place 3 Check the installation of the hood 4 The switch board or control board is defective 4 Change defective part The motor is working but the lights are not 1 Defective halogen bulb 1 Change the halogen bulb 2 The light bulb is loose 2 Tighten the light bulb The hood...

Страница 21: ...19 Wiring Diagrams ...

Страница 22: ...20 Wiring Diagrams ...

Страница 23: ...0020 Optional Accessories Recirculating Kit BRC 0003 for BFG BRC 0005 for BMI BRC 0001 for BVE Replacement Charcoal Filter Z0F C002 Duct Cover Extension up to 12 ceiling B1C 00MI for BMI BFG B1C 00VE for BVE To order parts visit us online at www brisasrangehoods com or call us at 1 888 880 8368 ...

Страница 24: ... labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABLE FOR INCIDENTAL CONSE QUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE PRODUCTS THE EXPRESS WARRANTIES IN THE PRECEDING SECTION ARE EXCLUSIVE AND IN LIEU O...

Отзывы: