background image

9

3. 

Make the Reverse Osmosis Waste Connections

The “RO” filter assembly requires a drain line connection to 

be installed, which removes rejected water to the sewer. The 

drain saddle connects the drain line from the dispenser to 

your drain pipe. The drain saddle is designed to fit around a 

standard 1.5 in. OD (outer diameter) drain pipe. 

Always install the drain saddle BEFORE the P-trap (15). 

Ensure the drain saddle is in place on a vertical or 

horizontal section of the pipe.

 To avoid clogging the drain line with debris, do not 

install the drain saddle on a section of piping that is 

located after the drain pipe meets a garbage disposal 

or dishwasher drain. 

To make the Reverse Osmosis (RO) drain connections:

A. 

Determine the location for your drain saddle (H) and 

then make a mark on the drain pipe for the opening 

(16).

B. 

Use your drill and a 1/4 in. drill bit to create a hole at 

the mark, ensuring you only drill through one side of 

the drain pipe.

C. 

Find the half of the drain saddle (H) with the hole in 

the center, remove the backing from the foam gasket, 

align the gasket with the hole on the drain saddle (H), 

and stick the adhesive side of the gasket to the drain 

saddle (H).

D. 

Position both halves of the drain saddle (H) on the 

drain pipe with the saddle’s opening aligned over the 

drilled hole, and insert your drill bit through the saddle 

(H) and drilled hole to ensure proper alignment.

E. 

Secure both ends of the drain saddle (H) together 

using the bolts and nuts, but do not overtighten.

F. 

Connect the RO waste water tube (I) to the drain 

saddle (H).

15

I

H

16

Содержание AQUUS TROE600COL

Страница 1: ...AQUUS Tankless 1 5 1 RO Filtration System with Smart Faucet Setup Manual Model No TROE600COL...

Страница 2: ...llation 7 Installation Overview 7 Connect to the Cold Water Supply 7 Make the Reverse Osmosis Waste Connections 9 Install the Faucet 10 Complete the Installation 11 Operation 11 Start Up the Filtratio...

Страница 3: ...o 58 PSI Install a pressure increasing or decreasing device if the water pressure is lower or higher than this level For use with municipal tap water only Not for use with well or underground water Do...

Страница 4: ...use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they are given supervision or instruction concerning the use of appli...

Страница 5: ...ress to flush newly installed filters Product Dimensions Height Width Depth 16 6 in 42 1 cm 5 2 in 13 2 cm 18 2 in 46 1 cm Materials Needed Phillips Head Screwdriver Adjustable Wrench Power Drill 1 4...

Страница 6: ...ty Part Description Quantity A RO filtration unit 1 G Plumbers tape 1 B Smart faucet 1 H Drain saddle 1 C Power adapter 1 I RO waste water tube 1 D Feed water adapter 1 J Shut off valve tube 1 E RO fi...

Страница 7: ...the COLD WATER LINE Using HOT WATER will severely damage your filters A Turn off and then disconnect the current cold water supply line B Connect the feed water adapter D to the cold water supply line...

Страница 8: ...valve with tube J straight into the quick connector piece of the feed water adapter D E Tighten the nut on the feed water adapter D J F Gently tug on the tube J to ensure a secure connection with the...

Страница 9: ...se Osmosis RO drain connections A Determine the location for your drain saddle H and then make a mark on the drain pipe for the opening 16 B Use your drill and a 1 4 in drill bit to create a hole at t...

Страница 10: ...you leave the O ring 19 on the faucet B C Attach one 1 4 in quick connector L to the long stem outlet filtered water and other 1 4 in quick connector to the short stem outlet RO filtered water B 19 17...

Страница 11: ...icator panel turns on NOTE When the system is first turned on it goes into automatic flushing state which lasts approximately 90 seconds 3 Open the RO lever on the smart faucet and allow RO water to r...

Страница 12: ...hs Removes up to 99 of contaminants including arsenic lead fluoride heavy metals and more Replacing the Filter When one or both of your filter indicator lights begin to flash or the smart faucet s fil...

Страница 13: ...t is normal for the RO filtered water flow to drop Increase ambient temperature The water quality is low A filter needs to be replaced The filtration system has not been used in more than 3 days The q...

Страница 14: ...tine maintenance on the Product as set out in the User s Manual In addition this Limited Warranty does not cover damages to the finish such as scratches dents discoloration or rust after purchase This...

Страница 15: ...2021 Brio Water Technology Inc Contact Us Call 1 844 257 4103...

Отзывы: