English Manual
CLEANING THE SPREADER
TROUBLESHOOTING
USE AND CARE
METHOD #1 -
Wipe spreader thoroughly with an oily cloth.
Oil all bearings and bearing areas.
METHOD #2 -
Wash, rinse, and dry the spreader.
Note: Drying takes time. Moisture trapped in bearing areas
is slow to go. Immediately after drying - oil all bearings and
moving parts. Make certain all operations are thorough.
NOTE:
Good “Dry Cleaning” is preferable to poor “Wet Cleaning”.
- It is virtually impossible to have rust and corrosion on a
clean, dry, oiled surface.
- Again (just before using) oil all bearings and moving parts.
- In storage, ideally the spreader should be hung by the
handle. In any case, do not pile weight on the spreader, as
excess weight over a period of time can distort the tires.
-
OIL BEARINGS AND ALL MOVING PARTS
- Make sure the spreader is running freely!
CLEAN AND OIL THE SPREADER IMMEDIATELY
AFTER EACH USE.
Problem
Possible Cause
Solution
Spreader does
not sit flat
The "feet" or the
flattened portion
of the spreader
hopper support
tubes are not bent
equally.
Using a hammer
or pliers, bend the
feet to be equal
with each other.
Deflector shut
off is binding
and will not
open/close
properly
Shut off plate
is jammed with
debris.
Thoroughly wash
out hopper and
shut off plates
with water.
Ensure debris is
not stuck between
shut off plate and
rate gate plate.
==================================================================================================
CALIBRATION
NOTE:
Dial settings are approximate only!
PRODUCT
PARTICLE SIZE
Lbs. per
1000 sq. ft.
Dial Setting
Full Rate
Once Over
Dial Settings
Half Rate
Twice Over
Fine Pellets
1
3.6
3.1
2
4.0
3.5
3
4.2
3.7
Mixed Fine
Pellets
2
3.7
3.2
4
4.7
4.1
6
5.2
4.5
Small Pellets
2
3
2.2
4
4.2
3.7
6
4.5
4
10
1019008-B