3  Safety instructions 

When  operating  the  pump,  the  safety  instructions 
contained  in  this  manual,  the  relevant  national 
accident  prevention  regulations  and  any  other 
service  and  safety  instructions  issued  by  the  plant 
operator are to be observed. 

3.1  Hazards in the event of non-compliance 

with the safety instructions 

Non-compliance with the safety instructions may 
produce a risk to the personnel as well as to the 
environment and the machine and results in a loss 
of any right to claim damages. 
For example, non-compliance may involve the 
following hazards: 

  Failure  of  important  functions  of  the  ma-

chines/plant  

  Failure  of  specified  procedures  of  maintenance 

and repair 

  Exposure of people to electrical, mechanical and 

chemical hazards 

  Endangering the environment  due  to hazardous 

substances being released 

3.2  Unauthorized modes of operation 

 

  Pump  may  not  be  used  in  potentially  explosive 

environments

!

 

  Pump and discharge piping are not designed  to 

hold any weight and may not be used as a step 
ladder. 

3.3  Remaining Risk 

 

Risk of Injury! 

Risk  of  squeezing  or  crushing  body  parts  when 
installing or removing the pump exists.  Proper and 
secured lifting tools must be used.  

 

Risk of burns! 

The pump must have cooled down sufficiently  prior 
to commencing any repair, maintenance or installa-
tion.  

3.4  Qualification and training of operating 

personnel 

The  personnel  responsible  for  operation,  mainte-
nance, inspection and assembly must be adequate-
ly qualified. Scope of responsibility and supervision 
of  the  personnel  must  be  exactly  defined  by  the 
plant operator. If the staff does not have the neces-
sary knowledge, they must be trained and instruct-
ed, which may be performed by the machine manu-
facturer  or  supplier  on  behalf  of  the  plant  operator. 
Moreover,  the  plant  operator  is  to  make  sure  that 
the  contents  of  the  operating  manual  are  fully 
understood by the personnel. 

3.5  Safety instructions relevant for operation 

  If  hot  or  cold  machine  components  involve 

hazards,  they  must  be  guarded  against  acci-
dental contact. 

  Guards for moving parts (e.g. coupling) must not 

be  removed  from  the  machine  while  in  opera-
tion. 

  Any leakage of hazardous (e.g. explosive, toxic, 

hot)  fluids  (e.g.  from  the  shaft  seal)  must  be 
drained  away  so  as  to  prevent  any  risk  to  per-
sons  or  the  environment.  Statutory  regulations 
are to be complied with. 

  Hazards  resulting  from  electricity  are  to  be 

prevented (see for example, the VDE Specifica-
tions and the bye-laws of the local power supply 
utilities). 

 

The  pumps’  stability  against  falling  over  is  not 
ensured  unless  it  is  properly  mounted  onto  the 
tank. 

  The female threads on the motor MUST NOT be 

used to lift the entire pump and motor assembly. 

 

 
 
Type 

 
 
Type 

Max. del. 
pressure bar / 
spec. weight 1 

Max. del. 
volume 
l/min 

Height 

1)  

 

H

 mm 

Depth of 
immersion  
STA

1, 2) 

 

h

 mm 

Weight  
STA

3)

 

 

g

 kg 

Power 

50     60 Hz 

kW 

Noise 
 level

4) 

STA 

dBA / 50 Hz 

STA1302  /  290 
 

/  390 

 

/  520 

 

/  640 

 

/  840 

 

/1070 

SAL1302  /  310 
 

/  410 

 

/  540 

 

/  660 

 

/  860 

 

/1090 

4.3 

1600 

612 

  290 

 390 

  520 
  640 
  840 
1070 

108 
110 
113 
118 
130 
137 

7.5 

 8.6  74 

STA1303  /  370 
 

/  470 

 

/  600 

 

/  720 

 

/  920 

 

/1150 

SAL1303  /  390 
 

/  490 

 

/  620 

 

/  740 

 

/  940 

 

/1170 

6.5 

1620 

620 

  370 

 470 

  600 
  720 
  920 
1150 

143 
146 
151 
155 
167 
174  

11.0  12.6  74 

1)  Dimensions in accordance with page 5 

2)

 

 

Depth of immersion

 

SAL = h + 20 mm ; 

3)

 

 

Weight  SAL = g + 1 kg  

4) 

 

Noise emissions measured in accordance with DIN 45635 at a distance of 1 m 

The motor is surface-cooled and compliant with 
DIN IEC 34 and EN 60034 (protection degree IP 55). 

 

Содержание SAL1001/1010

Страница 1: ...019 Page 1 of 10 BRINKMANN Immersion Pumps STA SAL901 1303 Brinkmann Pumpen K H Brinkmann GmbH Co KG Friedrichstra e 2 D 58791 Werdohl Tel 49 2392 5006 0 www brinkmannpumps de Fax 49 2392 5006 180 sal...

Страница 2: ...ps where the impellers are fixed on the driving shaft extension The pump shaft and motor shaft are interconnected by means of a shaft clamp Pump and motor form a compact and space saving unit These pu...

Страница 3: ...410 510 640 760 960 1190 SAL904 430 530 660 780 980 1210 8 6 1100 620 410 510 640 760 960 1190 150 153 157 161 176 180 11 0 12 6 74 STA1001 210 310 440 560 760 990 1110 SAL1001 230 330 460 580 780 101...

Страница 4: ...es not have the neces sary knowledge they must be trained and instruct ed which may be performed by the machine manu facturer or supplier on behalf of the plant operator Moreover the plant operator is...

Страница 5: ...ched on the motor and pump end Do not use the pump shaft for connecting any transportation aids such as hooks or straps Pumps must be drained prior to their storage Store pump in dry and protected are...

Страница 6: ...ng signals might occur Non sinus shaped supply voltage from a variable frequency drive might result in elevated motor temperatures 6 Start up Shut down 6 1 Start up ATTENTION Switch off at the mains A...

Страница 7: ...cation Power consumption is too high Wrong direction of rotation of impeller Lime or other deposits mechanical friction See above Clean pump mechanism repair pump Motor overheats High on off cycling f...

Страница 8: ...ng cover 7 5 kW and over 29 Socket head cap screw 7 5 kW DIN 931 30 Shaft nut 7 5 kW and over 50 Pump body 51 Shaft with rotor 52 Inlet cover for STA 52 Intake cover for SAL 53 Pump plate up STA SAL90...

Страница 9: ...surfaces of the insert shaft 2 inside and the motor shaft 3 They must not be lubricated or oiled Set the motor down on the fan cover Position the shaft clamp 1 use a new shaft clamp in the centre of t...