BRINKMANN PUMPS TAL200 Скачать руководство пользователя страница 7

 

BE1600 

Edition

 09/2021 

Page 7 of 9 

 

 

Trouble shooter’s guide 

Fault

 

Cause

 

Remedy

 

Motor does not start, no motor 
noise 

At least two of the power supply 
leads have failed  
 
Overload has tripped 

Check fuses, terminals and supply 
leads . 
 
 Inspect overload 

Motor does not start, humming noise

 

One of the supply leads has failed 
 
Impeller faulty 
Motor bearing faulty 

See above 
 
Replace impeller 
Replace bearing 

Overload trips 

Pump locked up mechanically 
High on/of cycling frequency 

Inspect pump hydraulics 
Check application 

Power consumption is too high 

Wrong direction of rotation of 
impeller 
Lime or other deposits 
mechanical friction 

See above 
 
Clean pump mechanism  
repair pump 

Motor overheats 

High on/off cycling frequency 
Wrong power supply (voltage or 
cycles) 
 
Insufficient cooling 

See above 
Power supply must correspond with 
name plate rating 
 
Check air flow at motor fan 

Pump does not pump 

liquid level too low 
Pump mechanism faulty 
Pipe blocked 

Fill up liquid 
replace pump mechanism 
Clean pipe 

Insufficient flow and pressure 

Wrong direction of rotation of 
impeller  
 
Pump mechanism silted up 
Worn pump mechanism 

Change over two power supply 
leads 
 
Clean pump mechanism  
Replace pump mechanism 

Incorrect flow or pressure 

Wrong power supply (voltage or 
cycles) 

Power supply must correspond with 
name plate rating 

Running noise/Vibration 

Foreign objects in pump end 
Impeller damaged 
Bearing/Bushing broken 

Remove foreign objects 
Replace impeller 
Replace bearing/bushing 

Содержание TAL200

Страница 1: ...ge 1 of 9 BRINKMANN Immersion Pumps TAL200 401 601 TGL331 TGL501 Brinkmann Pumpen K H Brinkmann GmbH Co KG Friedrichstra e 2 D 58791 Werdohl Tel 49 2392 5006 0 www brinkmannpumps de Fax 49 2392 5006 1...

Страница 2: ...word ATTENTION is inserted 2 Description of product 2 1 General description of the pump Pumps of this type are one stage rotary pumps where the impellers are fixed on the driving shaft extension Pump...

Страница 3: ...9 400 264 G 1 140 220 290 370 460 570 15 0 16 0 16 5 17 5 19 0 20 0 0 85 0 98 TAL601 150 230 300 380 470 580 1 3 520 291 G 1 150 230 300 380 470 580 16 0 17 5 18 5 19 5 20 5 21 5 1 1 1 27 TGL331 140...

Страница 4: ...ards they must be guarded against acci dental contact Guards for moving parts e g coupling must not be removed from the machine while in opera tion Any leakage of hazardous e g explosive toxic hot flu...

Страница 5: ...st be carried out by quali fied service personnel Pump must be discon nected from the power source and all rotating parts must stand still Reassure that pump is disconnected from power source and cann...

Страница 6: ...ere is no voltage at the terminal board Open terminal box and disconnect the power leads Empty out the pump 7 Operation Liquid level According to the drawing shown below the maxi mum liquid level must...

Страница 7: ...above Clean pump mechanism repair pump Motor overheats High on off cycling frequency Wrong power supply voltage or cycles Insufficient cooling See above Power supply must correspond with name plate r...

Страница 8: ...m Pos 15 3 Nm Pos 18 4 5 Nm 11 Disposal When disposing of the pump or the packaging materials the local and national regulation for proper disposal must be complied with Prior to its disposal the pump...

Страница 9: ...chinenrichtlinie 2006 42 EG die Schutz ziele der Niederspannungsrichtlinie 2014 35 EU eingehalten With respect to potential electrical hazards as stated in appendix No 1 5 1 of the machine guide lines...

Отзывы: