6  Start up / Shut down 

6.1  Start up 

 ATTENTION  

Switch off at the mains. 
After connection the electrical wires, close the 
terminal box. Briefly start the motor (max. 30 sec.) 
and check the rotation according to the arrow on 
the top of the motor. 
If  the  direction  is  incorrect  change  over  two  of  the 
power leads. 

6.2  Shut down  

All  service  work  must  be  carried  out  by  qualified 
service  personnel.    Pump  must  be  disconnected 
from  the  power  source  and  all  rotating  parts  must 
stand  still.    Reassure  that  pump  is  disconnected 
from  power  source  and  cannot  be  switched  on.  
Verify that there is no voltage at the terminal board! 
Open terminal box and disconnect the power leads. 
Empty out the pump. 

7  Operation 

Liquid level 

According  to  the  drawing  shown  below,  the  maxi-
mum liquid level must stay about 30 mm below the 
mounting  flange,  also  ensure  that  the  suction  hole 
of  the  pump  body  must  be  covered  with  liquid 
before starting up the motor. 

 
 

 
 
 

 

If  the  pump  should  lock  up  and  cease,  shut 
pump  down  (see  6.2)  and  disconnect  from 
power  supply.  Pump  must  be  uninstalled  and 
removed from the system prior to its repair. 

8  Servicing and Maintenance 

 ATTENTION  

The surface of the motor must be kept free of dirt.  

The motor shaft is spinning in permanently greased 
ball  bearings  (with  special  grease  and  increased 
bearing  play)  and  does  not  require  any  special 
maintenance. 
 

 

 

 

 
 
 
 
 

 

 

max. liquid  
level 

min. liquid 
level 

Содержание TAL200

Страница 1: ...ge 1 of 9 BRINKMANN Immersion Pumps TAL200 401 601 TGL331 TGL501 Brinkmann Pumpen K H Brinkmann GmbH Co KG Friedrichstra e 2 D 58791 Werdohl Tel 49 2392 5006 0 www brinkmannpumps de Fax 49 2392 5006 1...

Страница 2: ...word ATTENTION is inserted 2 Description of product 2 1 General description of the pump Pumps of this type are one stage rotary pumps where the impellers are fixed on the driving shaft extension Pump...

Страница 3: ...9 400 264 G 1 140 220 290 370 460 570 15 0 16 0 16 5 17 5 19 0 20 0 0 85 0 98 TAL601 150 230 300 380 470 580 1 3 520 291 G 1 150 230 300 380 470 580 16 0 17 5 18 5 19 5 20 5 21 5 1 1 1 27 TGL331 140...

Страница 4: ...ards they must be guarded against acci dental contact Guards for moving parts e g coupling must not be removed from the machine while in opera tion Any leakage of hazardous e g explosive toxic hot flu...

Страница 5: ...st be carried out by quali fied service personnel Pump must be discon nected from the power source and all rotating parts must stand still Reassure that pump is disconnected from power source and cann...

Страница 6: ...ere is no voltage at the terminal board Open terminal box and disconnect the power leads Empty out the pump 7 Operation Liquid level According to the drawing shown below the maxi mum liquid level must...

Страница 7: ...above Clean pump mechanism repair pump Motor overheats High on off cycling frequency Wrong power supply voltage or cycles Insufficient cooling See above Power supply must correspond with name plate r...

Страница 8: ...m Pos 15 3 Nm Pos 18 4 5 Nm 11 Disposal When disposing of the pump or the packaging materials the local and national regulation for proper disposal must be complied with Prior to its disposal the pump...

Страница 9: ...chinenrichtlinie 2006 42 EG die Schutz ziele der Niederspannungsrichtlinie 2014 35 EU eingehalten With respect to potential electrical hazards as stated in appendix No 1 5 1 of the machine guide lines...

Отзывы: